A list of cpu bandwidth table entries.
Sources for this description
FS.COM official Documentation Hub native MIB packagesFS.COM MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.52642.9.1.1.1.2
A list of cpu bandwidth table entries.
Identification
{1 3 6 1 4 1 52642 9 1 1 1 2}
Definitions may combine these properties differently.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Product context
The FS.COM catalogue lists MIB packages containing this definition for these models:
IES3100-16TM, IES3100-8T4F-P, IES3100-8TF, IES3100-8TF-P, S3150-8T2FP, S3400-24T4FP, S3400-24T4SP, S3400-48T4SP, S3400-48T6SP, S5500-48T6SP-R.
A definition in a model's MIB package does not establish that the device implements it or permits access.
Available source records contain 2 distinct definitions; some records may not include a definition.
cpuBandwidthTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpuBandwidthEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of cpu bandwidth table entries."
::= { switchSystem 2 }cpuBandwidthTable OBJECT-TYPE
SYNTAX SEQUENCE OF cpuBandwidthEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of cpu bandwidth table entries."
::= { switchSystem 2 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
A list of cpu bandwidth table entries.
FS.COM official Documentation Hub native MIB packagesFS.COM MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: mandatory.
Names: cpuBandwidthTable
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"cpuBandwidthTable",
"OBJECT-TYPE",
"SYNTAX",
"SEQUENCE",
"OF",
"CpuBandwidthEntry",
"ACCESS",
"not-accessible",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"A list of cpu bandwidth table entries.\"",
"::=",
"{",
"switchSystem",
"2",
"}"
],
"syntax_tree": [
[
"conceptualTable",
[
"row",
"CpuBandwidthEntry"
]
],
null,
[
"MaxAccessPart",
"not-accessible"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"A list of cpu bandwidth table entries."
],
null,
null,
null,
null
]
}Module: NMS-SWITCH-MIB
See published definition above
{'IF-MIB': ['ifIndex'], 'NMS-SMI': ['nmsMgmt'], 'SNMPv2-TC': ['PhysAddress', 'RowStatus', 'MacAddress', 'TruthValue'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE'], 'RFC1155-SMI': ['Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress']}Related source files and packages:
Same file in s3150-8t2fp-switch-snmp-mib-files.zip.
Same file in ies3100-series-switches-snmp-mib-files.zip.
Same file in 202305060956260ayqlm.zip.
Status in source: mandatory.
Names: cpuBandwidthTable
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"cpuBandwidthTable",
"OBJECT-TYPE",
"SYNTAX",
"SEQUENCE",
"OF",
"cpuBandwidthEntry",
"ACCESS",
"not-accessible",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"A list of cpu bandwidth table entries.\"",
"::=",
"{",
"switchSystem",
"2",
"}"
],
"syntax_tree": [
[
"conceptualTable",
[
"row",
"cpuBandwidthEntry"
]
],
null,
[
"MaxAccessPart",
"not-accessible"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"A list of cpu bandwidth table entries."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive. FS.COM support.
Module: FS-NMS-SWITCH-MIB
See published definition above
{'IF-MIB': ['ifIndex'], 'SNMPv2-TC': ['PhysAddress', 'RowStatus', 'MacAddress', 'TruthValue'], 'FS-NMS-SMI': ['nmsMgmt'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE'], 'RFC1155-SMI': ['Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.52642.9.1.1.1.2.1 | cpuBandwidthEntry | 2 | 2 |
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.52642.9.1.1.1.1 | switchHALGlobal | 22 | 22 |