Reference record for OID 1.3.6.1.4.1.52642.9.63.1.7.1.38

Parent
1.3.6.1.4.1.52642.9.63.1.7.1 (ifSfpParameterEntry)
Node code
38
Node name
txPowerLowWarning
Numeric OID
1.3.6.1.4.1.52642.9.63.1.7.1.38
URN notation
urn:oid:1.3.6.1.4.1.52642.9.63.1.7.1.38
ASN.1 notation

{1 3 6 1 4 1 52642 9 63 1 7 1 38}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) fs(52642) nmsMgmt(9) nmsIfMIB(63) nmsIfObjects(1) ifSfpParameterTable(7) ifSfpParameterEntry(1) txPowerLowWarning(38)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) fs(52642) nmsMgmt(9) nmsIfMIB(63) vtssArpInspectionMibObjects(1) ifSfpParameterTable(7) ifSfpParameterEntry(1) txPowerLowWarning(38)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) fs(52642) nmsMgmt(9) vtssArpInspectionMib(63) nmsIfObjects(1) ifSfpParameterTable(7) ifSfpParameterEntry(1) txPowerLowWarning(38)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) fs(52642) nmsMgmt(9) vtssArpInspectionMib(63) vtssArpInspectionMibObjects(1) ifSfpParameterTable(7) ifSfpParameterEntry(1) txPowerLowWarning(38)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) fs(52642) vtssSwitchMgmt(9) nmsIfMIB(63) nmsIfObjects(1) ifSfpParameterTable(7) ifSfpParameterEntry(1) txPowerLowWarning(38)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) fs(52642) vtssSwitchMgmt(9) nmsIfMIB(63) vtssArpInspectionMibObjects(1) ifSfpParameterTable(7) ifSfpParameterEntry(1) txPowerLowWarning(38)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) fs(52642) vtssSwitchMgmt(9) vtssArpInspectionMib(63) nmsIfObjects(1) ifSfpParameterTable(7) ifSfpParameterEntry(1) txPowerLowWarning(38)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) fs(52642) vtssSwitchMgmt(9) vtssArpInspectionMib(63) vtssArpInspectionMibObjects(1) ifSfpParameterTable(7) ifSfpParameterEntry(1) txPowerLowWarning(38)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) fs(52642) fsSurveillanceMIB(9) nmsIfMIB(63) nmsIfObjects(1) ifSfpParameterTable(7) ifSfpParameterEntry(1) txPowerLowWarning(38)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) fs(52642) fsSurveillanceMIB(9) nmsIfMIB(63) vtssArpInspectionMibObjects(1) ifSfpParameterTable(7) ifSfpParameterEntry(1) txPowerLowWarning(38)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) fs(52642) fsSurveillanceMIB(9) vtssArpInspectionMib(63) nmsIfObjects(1) ifSfpParameterTable(7) ifSfpParameterEntry(1) txPowerLowWarning(38)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) fs(52642) fsSurveillanceMIB(9) vtssArpInspectionMib(63) vtssArpInspectionMibObjects(1) ifSfpParameterTable(7) ifSfpParameterEntry(1) txPowerLowWarning(38)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nms(52642) nmsMgmt(9) nmsIfMIB(63) nmsIfObjects(1) ifSfpParameterTable(7) ifSfpParameterEntry(1) txPowerLowWarning(38)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nms(52642) nmsMgmt(9) nmsIfMIB(63) vtssArpInspectionMibObjects(1) ifSfpParameterTable(7) ifSfpParameterEntry(1) txPowerLowWarning(38)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nms(52642) nmsMgmt(9) vtssArpInspectionMib(63) nmsIfObjects(1) ifSfpParameterTable(7) ifSfpParameterEntry(1) txPowerLowWarning(38)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nms(52642) nmsMgmt(9) vtssArpInspectionMib(63) vtssArpInspectionMibObjects(1) ifSfpParameterTable(7) ifSfpParameterEntry(1) txPowerLowWarning(38)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/52642/9/63/1/7/1/38
  • /ISO/Identified-Organization/6/1/4/1/52642/9/63/1/7/1/38
  • /ISO/3/6/1/4/1/52642/9/63/1/7/1/38
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/fs/nmsMgmt/nmsIfMIB/nmsIfObjects/ifSfpParameterTable/ifSfpParameterEntry/txPowerLowWarning
  • /iso/identified-organization/dod/internet/private/enterprise/fs/nmsMgmt/nmsIfMIB/vtssArpInspectionMibObjects/ifSfpParameterTable/ifSfpParameterEntry/txPowerLowWarning
  • /iso/identified-organization/dod/internet/private/enterprise/fs/nmsMgmt/vtssArpInspectionMib/nmsIfObjects/ifSfpParameterTable/ifSfpParameterEntry/txPowerLowWarning
  • /iso/identified-organization/dod/internet/private/enterprise/fs/nmsMgmt/vtssArpInspectionMib/vtssArpInspectionMibObjects/ifSfpParameterTable/ifSfpParameterEntry/txPowerLowWarning
  • /iso/identified-organization/dod/internet/private/enterprise/fs/vtssSwitchMgmt/nmsIfMIB/nmsIfObjects/ifSfpParameterTable/ifSfpParameterEntry/txPowerLowWarning
  • /iso/identified-organization/dod/internet/private/enterprise/fs/vtssSwitchMgmt/nmsIfMIB/vtssArpInspectionMibObjects/ifSfpParameterTable/ifSfpParameterEntry/txPowerLowWarning
  • /iso/identified-organization/dod/internet/private/enterprise/fs/vtssSwitchMgmt/vtssArpInspectionMib/nmsIfObjects/ifSfpParameterTable/ifSfpParameterEntry/txPowerLowWarning
  • /iso/identified-organization/dod/internet/private/enterprise/fs/vtssSwitchMgmt/vtssArpInspectionMib/vtssArpInspectionMibObjects/ifSfpParameterTable/ifSfpParameterEntry/txPowerLowWarning
  • /iso/identified-organization/dod/internet/private/enterprise/fs/fsSurveillanceMIB/nmsIfMIB/nmsIfObjects/ifSfpParameterTable/ifSfpParameterEntry/txPowerLowWarning
  • /iso/identified-organization/dod/internet/private/enterprise/fs/fsSurveillanceMIB/nmsIfMIB/vtssArpInspectionMibObjects/ifSfpParameterTable/ifSfpParameterEntry/txPowerLowWarning
  • /iso/identified-organization/dod/internet/private/enterprise/fs/fsSurveillanceMIB/vtssArpInspectionMib/nmsIfObjects/ifSfpParameterTable/ifSfpParameterEntry/txPowerLowWarning
  • /iso/identified-organization/dod/internet/private/enterprise/fs/fsSurveillanceMIB/vtssArpInspectionMib/vtssArpInspectionMibObjects/ifSfpParameterTable/ifSfpParameterEntry/txPowerLowWarning
  • /iso/identified-organization/dod/internet/private/enterprise/nms/nmsMgmt/nmsIfMIB/nmsIfObjects/ifSfpParameterTable/ifSfpParameterEntry/txPowerLowWarning
  • /iso/identified-organization/dod/internet/private/enterprise/nms/nmsMgmt/nmsIfMIB/vtssArpInspectionMibObjects/ifSfpParameterTable/ifSfpParameterEntry/txPowerLowWarning
  • /iso/identified-organization/dod/internet/private/enterprise/nms/nmsMgmt/vtssArpInspectionMib/nmsIfObjects/ifSfpParameterTable/ifSfpParameterEntry/txPowerLowWarning
  • /iso/identified-organization/dod/internet/private/enterprise/nms/nmsMgmt/vtssArpInspectionMib/vtssArpInspectionMibObjects/ifSfpParameterTable/ifSfpParameterEntry/txPowerLowWarning
  • Additional combinations skipped.

Descriptions

txPowerLowWarning — FS.COM official Documentation Hub native MIB packages, FS.COM MIB copies (LibreNMS/Observium Community)

Tx Power Low Warning Threshold. Unit is 0.01dBm.

Source records

txPowerLowWarning

Status in source: mandatory.

Names: txPowerLowWarning

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "txPowerLowWarning",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "ACCESS",
    "read-only",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"Tx Power Low Warning Threshold. Unit is 0.01dBm.\"",
    "::=",
    "{",
    "ifSfpParameterEntry",
    "38",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER"
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "Tx Power Low Warning Threshold. Unit is 0.01dBm."
    ],
    null,
    null,
    null,
    null
  ]
}
  • FS.COM MIB copies (LibreNMS/Observium Community) · Publisher's source file: NMS-IF-MIB

    Vendor MIB copy from the LibreNMS archive. FS.COM support.

    Module: NMS-IF-MIB

    Published definition
    txPowerLowWarning OBJECT-TYPE
                     SYNTAX  INTEGER
                     ACCESS  read-only
                     STATUS  mandatory
                     DESCRIPTION
                             "Tx Power Low Warning Threshold. Unit is 0.01dBm."
                     ::= { ifSfpParameterEntry 38 }
    Module imports
    {'NMS-SMI': ['nmsMgmt'], 'SNMPv2-TC': ['PhysAddress'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Gauge32', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString']}

    Related source files and packages:


    Source location: NMS-IF-MIB::txPowerLowWarning.
    Source version and references

    Downloaded: 2026-10-23T19:25:11.682116+00:00.

  • FS.COM official Documentation Hub native MIB packages · Publisher's source file: Source package: s3150-8t2fp-switch-snmp-mib-files.zip

    Module: NMS-IF-MIB

    Published definition
    txPowerLowWarning OBJECT-TYPE
                     SYNTAX  INTEGER
                     ACCESS  read-only
                     STATUS  mandatory
                     DESCRIPTION
                             "Tx Power Low Warning Threshold. Unit is 0.01dBm."
                     ::= { ifSfpParameterEntry 38 }
    Module imports
    {'NMS-SMI': ['nmsMgmt'], 'SNMPv2-TC': ['PhysAddress'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Gauge32', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString']}

    Related source files and packages:

    • S3150-8T2FP Switch SNMP MIB FilesS3150-8T2FP Switch SNMP MIB Files; Models: S3150-8T2FP; Catalog updated: 2026-10-08 11:35:03; File: mall/resource/s3150-8t2fp-switch-snmp-mib-files.zip; Publisher Last-Modified: Thu, 08 Oct 2026 03:35:03 GMT; 427,755 bytes

    Source location: NMS-IF-MIB::txPowerLowWarning.
    Source version and references

    Downloaded: 2026-10-24T13:35:25.463796+00:00.

Current Registration Authority (inferred from ancestor 1.3.6.1.4.1.52642)

FS.COM INC

Siblings (43)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.52642.9.63.1.7.1.1 ifSfpIndex, IfIndex00
1.3.6.1.4.1.52642.9.63.1.7.1.2 txPower100
1.3.6.1.4.1.52642.9.63.1.7.1.3 rxPower100
1.3.6.1.4.1.52642.9.63.1.7.1.4 temperature00
1.3.6.1.4.1.52642.9.63.1.7.1.5 vlotage00
1.3.6.1.4.1.52642.9.63.1.7.1.6 curr100
1.3.6.1.4.1.52642.9.63.1.7.1.7 vendname00
1.3.6.1.4.1.52642.9.63.1.7.1.8 txPower200
1.3.6.1.4.1.52642.9.63.1.7.1.9 rxPower200
1.3.6.1.4.1.52642.9.63.1.7.1.10 curr200
1.3.6.1.4.1.52642.9.63.1.7.1.11 txPower300
1.3.6.1.4.1.52642.9.63.1.7.1.12 rxPower300
1.3.6.1.4.1.52642.9.63.1.7.1.13 curr300
1.3.6.1.4.1.52642.9.63.1.7.1.14 txPower400
1.3.6.1.4.1.52642.9.63.1.7.1.15 rxPower400
1.3.6.1.4.1.52642.9.63.1.7.1.16 curr400
1.3.6.1.4.1.52642.9.63.1.7.1.17 type00
1.3.6.1.4.1.52642.9.63.1.7.1.18 transDist00
1.3.6.1.4.1.52642.9.63.1.7.1.19 waveLen00
1.3.6.1.4.1.52642.9.63.1.7.1.20 sfpPresentStatus00
1.3.6.1.4.1.52642.9.63.1.7.1.21 sfpLostStatus00
1.3.6.1.4.1.52642.9.63.1.7.1.22 sfpMismatchStatus00
1.3.6.1.4.1.52642.9.63.1.7.1.23 sfpSeqNum00
1.3.6.1.4.1.52642.9.63.1.7.1.24 voltageHighAlarm00
1.3.6.1.4.1.52642.9.63.1.7.1.25 voltageHighWarning00
1.3.6.1.4.1.52642.9.63.1.7.1.26 voltageLowWarning00
1.3.6.1.4.1.52642.9.63.1.7.1.27 voltageLowAlarm00
1.3.6.1.4.1.52642.9.63.1.7.1.28 temperatureHighAlarm00
1.3.6.1.4.1.52642.9.63.1.7.1.29 temperatureHighWarning00
1.3.6.1.4.1.52642.9.63.1.7.1.30 temperatureLowWarning00
1.3.6.1.4.1.52642.9.63.1.7.1.31 temperatureLowAlarm00
1.3.6.1.4.1.52642.9.63.1.7.1.32 biasHighAlarm00
1.3.6.1.4.1.52642.9.63.1.7.1.33 biasHighWarning00
1.3.6.1.4.1.52642.9.63.1.7.1.34 biasLowWarning00
1.3.6.1.4.1.52642.9.63.1.7.1.35 biasLowAlarm00
1.3.6.1.4.1.52642.9.63.1.7.1.36 txPowerHighAlarm00
1.3.6.1.4.1.52642.9.63.1.7.1.37 txPowerHighWarning00
1.3.6.1.4.1.52642.9.63.1.7.1.39 txPowerLowAlarm00
1.3.6.1.4.1.52642.9.63.1.7.1.40 rxPowerHighAlarm00
1.3.6.1.4.1.52642.9.63.1.7.1.41 rxPowerHighWarning00
1.3.6.1.4.1.52642.9.63.1.7.1.42 rxPowerLowWarning00
1.3.6.1.4.1.52642.9.63.1.7.1.43 rxPowerLowAlarm00
1.3.6.1.4.1.52642.9.63.1.7.1.44 vendorPN00