airFlowSensorValue — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
The air flow measured by the sensor in tenths of a meter per minute.
{1 3 6 1 4 1 52674 500 4 1 5 1 2}
The air flow measured by the sensor in tenths of a meter per minute.
Status in source: current.
Names: airFlowSensorValue
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"airFlowSensorValue",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"(",
"0",
".",
".",
"10000",
")",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"The air flow measured by the sensor in tenths of a meter per minute.\"",
"::=",
"{",
"airFlowSensorEntry",
"2",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32",
[
"integerSubType",
[
[
0,
10000
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The air flow measured by the sensor in tenths of a meter per minute."
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: NetBotz50-MIB
airFlowSensorValue OBJECT-TYPE
SYNTAX Integer32 (0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The air flow measured by the sensor in tenths of a meter per minute."
::= { airFlowSensorEntry 2 }{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString', 'DateAndTime'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises', 'Counter32', 'Integer32'], 'SNMPv2-CONF': ['NOTIFICATION-GROUP', 'OBJECT-GROUP']}Related source files and packages:
Downloaded: 2026-10-24T02:14:16.195291+00:00.
Vendor MIB copy from the Observium Community archive.
Module: NetBotz50-MIB
airFlowSensorValue OBJECT-TYPE
SYNTAX Integer32 (0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The air flow measured by the sensor in tenths of a meter per minute."
::= { airFlowSensorEntry 2 }{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString', 'DateAndTime'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises', 'Counter32', 'Integer32'], 'SNMPv2-CONF': ['NOTIFICATION-GROUP', 'OBJECT-GROUP']}Related source files and packages:
Downloaded: 2026-10-24T02:14:28.023136+00:00.
Schneider Electric / APC NetBotz
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.52674.500.4.1.5.1.1 | airFlowSensorId | 0 | 0 | |
| 1.3.6.1.4.1.52674.500.4.1.5.1.3 | airFlowSensorErrorStatus | 0 | 0 | |
| 1.3.6.1.4.1.52674.500.4.1.5.1.4 | airFlowSensorLabel | 0 | 0 | |
| 1.3.6.1.4.1.52674.500.4.1.5.1.5 | airFlowSensorEncId | 0 | 0 | |
| 1.3.6.1.4.1.52674.500.4.1.5.1.6 | airFlowSensorPortId | 0 | 0 | |
| 1.3.6.1.4.1.52674.500.4.1.5.1.7 | airFlowSensorValueStr | 0 | 0 | |
| 1.3.6.1.4.1.52674.500.4.1.5.1.8 | airFlowSensorValueInt | 0 | 0 | |
| 1.3.6.1.4.1.52674.500.4.1.5.1.9 | airFlowSensorIndex | 0 | 0 |