errorCondResolvedTimeStr — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
The time the error condition was resolved (if it was resolved), as ISO date-time formatted string (UTC).
{1 3 6 1 4 1 52674 500 5 1 1 8}
The time the error condition was resolved (if it was resolved), as ISO date-time formatted string (UTC).
Status in source: current.
Names: errorCondResolvedTimeStr
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"errorCondResolvedTimeStr",
"OBJECT-TYPE",
"SYNTAX",
"DisplayString",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"The time the error condition was resolved (if it was resolved), as ISO date-time formatted string (UTC).\"",
"::=",
"{",
"errorCondEntry",
"8",
"}"
],
"syntax_tree": [
[
"row",
"DisplayString"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The time the error condition was resolved (if it was resolved), as ISO date-time formatted string (UTC)."
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: NetBotz50-MIB
errorCondResolvedTimeStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time the error condition was resolved (if it was resolved), as ISO date-time formatted string (UTC)."
::= { errorCondEntry 8 }{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString', 'DateAndTime'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises', 'Counter32', 'Integer32'], 'SNMPv2-CONF': ['NOTIFICATION-GROUP', 'OBJECT-GROUP']}Related source files and packages:
Downloaded: 2026-10-24T02:14:16.195291+00:00.
Vendor MIB copy from the Observium Community archive.
Module: NetBotz50-MIB
errorCondResolvedTimeStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time the error condition was resolved (if it was resolved), as ISO date-time formatted string (UTC)."
::= { errorCondEntry 8 }{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString', 'DateAndTime'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises', 'Counter32', 'Integer32'], 'SNMPv2-CONF': ['NOTIFICATION-GROUP', 'OBJECT-GROUP']}Related source files and packages:
Downloaded: 2026-10-24T02:14:28.023136+00:00.
Schneider Electric / APC NetBotz
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.52674.500.5.1.1.1 | errorCondId | 0 | 0 | |
| 1.3.6.1.4.1.52674.500.5.1.1.2 | errorCondSeverity | 0 | 0 | |
| 1.3.6.1.4.1.52674.500.5.1.1.3 | errorCondTypeId | 0 | 0 | |
| 1.3.6.1.4.1.52674.500.5.1.1.4 | errorCondStartTime | 0 | 0 | |
| 1.3.6.1.4.1.52674.500.5.1.1.5 | errorCondStartTimeStr | 0 | 0 | |
| 1.3.6.1.4.1.52674.500.5.1.1.6 | errorCondResolved | 0 | 0 | |
| 1.3.6.1.4.1.52674.500.5.1.1.7 | errorCondResolvedTime | 0 | 0 | |
| 1.3.6.1.4.1.52674.500.5.1.1.9 | errorCondEncId | 0 | 0 | |
| 1.3.6.1.4.1.52674.500.5.1.1.10 | errorCondPortId | 0 | 0 | |
| 1.3.6.1.4.1.52674.500.5.1.1.11 | errorCondSensorId | 0 | 0 | |
| 1.3.6.1.4.1.52674.500.5.1.1.12 | errorCondIndex | 0 | 0 |