The value of the upper critical reset/hysteresis value.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.534.6.6.6.2.4.1.11
The value of the upper critical reset/hysteresis value.
Identification
{1 3 6 1 4 1 534 6 6 6 2 4 1 11}
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
humidityUpperCriticalReset OBJECT-TYPE
SYNTAX RelativeHumidity
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of the upper critical reset/hysteresis value."
::= { humiditySensorEntry 11 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
The value of the upper critical reset/hysteresis value.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: humidityUpperCriticalReset
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"humidityUpperCriticalReset",
"OBJECT-TYPE",
"SYNTAX",
"RelativeHumidity",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"The value of the upper critical reset/hysteresis value.\"",
"::=",
"{",
"humiditySensorEntry",
"11",
"}"
],
"syntax_tree": [
[
"row",
"RelativeHumidity"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The value of the upper critical reset/hysteresis value."
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: PDU-MIB
See published definition above
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString', 'MacAddress'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises', 'Integer32', 'IpAddress', 'Opaque'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP']}Related source files and packages:
Vendor MIB copy from the Observium Community archive.
Module: EATON-EPDU-MA-MIB
Same published definition (formatting differs; exact original is in the source file)
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString', 'MacAddress'], 'EATON-OIDS': ['pduAgent'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Integer32', 'IpAddress', 'Unsigned32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.534.6.6.6.2.4.1.1 | humiditySensorIndex | 0 | 0 | |
| 1.3.6.1.4.1.534.6.6.6.2.4.1.2 | humiditySensorLabel | 0 | 0 | |
| 1.3.6.1.4.1.534.6.6.6.2.4.1.3 | humidity | 0 | 0 | |
| 1.3.6.1.4.1.534.6.6.6.2.4.1.4 | humidityLowerWarning | 0 | 0 | |
| 1.3.6.1.4.1.534.6.6.6.2.4.1.5 | humidityUpperWarning | 0 | 0 | |
| 1.3.6.1.4.1.534.6.6.6.2.4.1.6 | humidityLowerCritical | 0 | 0 | |
| 1.3.6.1.4.1.534.6.6.6.2.4.1.7 | humidityUpperCritical | 0 | 0 | |
| 1.3.6.1.4.1.534.6.6.6.2.4.1.8 | humidityLowerWarningReset | 0 | 0 | |
| 1.3.6.1.4.1.534.6.6.6.2.4.1.9 | humidityUpperWarningReset | 0 | 0 | |
| 1.3.6.1.4.1.534.6.6.6.2.4.1.10 | humidityLowerCriticalReset | 0 | 0 |