A collection of objects providing external humidity sensor readings and threshold settings.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.534.6.6.6.9.2.7
A collection of objects providing external humidity sensor readings and threshold settings.
Identification
{1 3 6 1 4 1 534 6 6 6 9 2 7}
The displayed source records contain one distinct definition. Compare its source records.
externalHumidityGroup OBJECT-GROUP
OBJECTS { humiditySensorCount,
humiditySensorLabel,
humidity,
humidityLowerWarning,
humidityUpperWarning,
humidityLowerCritical,
humidityUpperCritical,
humidityLowerWarningReset,
humidityUpperWarningReset,
humidityLowerCriticalReset,
humidityUpperCriticalReset }
STATUS current
DESCRIPTION
"A collection of objects providing external humidity sensor readings and threshold settings."
::= { groups 7 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
A collection of objects providing external humidity sensor readings and threshold settings.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: externalHumidityGroup
{
"smi_kind": "OBJECT-GROUP",
"definition": [
"externalHumidityGroup",
"OBJECT-GROUP",
"OBJECTS",
"{",
"humiditySensorCount",
",",
"humiditySensorLabel",
",",
"humidity",
",",
"humidityLowerWarning",
",",
"humidityUpperWarning",
",",
"humidityLowerCritical",
",",
"humidityUpperCritical",
",",
"humidityLowerWarningReset",
",",
"humidityUpperWarningReset",
",",
"humidityLowerCriticalReset",
",",
"humidityUpperCriticalReset",
"}",
"STATUS",
"current",
"DESCRIPTION",
"\"A collection of objects providing external humidity sensor readings and threshold settings.\"",
"::=",
"{",
"groups",
"7",
"}"
],
"syntax_tree": [
[
"Objects",
[
"humiditySensorCount",
"humiditySensorLabel",
"humidity",
"humidityLowerWarning",
"humidityUpperWarning",
"humidityLowerCritical",
"humidityUpperCritical",
"humidityLowerWarningReset",
"humidityUpperWarningReset",
"humidityLowerCriticalReset",
"humidityUpperCriticalReset"
]
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"A collection of objects providing external humidity sensor readings and threshold settings."
],
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: PDU-MIB
See published definition above
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString', 'MacAddress'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises', 'Integer32', 'IpAddress', 'Opaque'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP']}Related source files and packages:
Vendor MIB copy from the Observium Community archive.
Module: EATON-EPDU-MA-MIB
Same published definition (formatting differs; exact original is in the source file)
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString', 'MacAddress'], 'EATON-OIDS': ['pduAgent'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Integer32', 'IpAddress', 'Unsigned32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.534.6.6.6.9.2.1 | infoGroup | 0 | 0 | |
| 1.3.6.1.4.1.534.6.6.6.9.2.2 | outletsGroup | 0 | 0 | |
| 1.3.6.1.4.1.534.6.6.6.9.2.4 | unitSensorsGroup | 0 | 0 | |
| 1.3.6.1.4.1.534.6.6.6.9.2.6 | externalTemperatureGroup | 0 | 0 | |
| 1.3.6.1.4.1.534.6.6.6.9.2.9 | trapsGroup | 0 | 0 |