Status of the external communication with a strapping unit.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.534.6.6.7.1.2.1.32
Status of the external communication with a strapping unit.
Identification
{1 3 6 1 4 1 534 6 6 7 1 2 1 32}
| Value | Name |
|---|---|
| 0 | good |
| 1 | communicationLost |
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.
In EATON-EPDU-MIB, the row index strappingIndex is declared as Integer32. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.534.6.6.7.1.2.1.32.<strappingIndex>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.534.6.6.7.1.2.1.32
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
strappingStatus OBJECT-TYPE
SYNTAX INTEGER {
good (0),
communicationLost (1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of the external communication with a strapping unit."
::= { unitEntry 32 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Status of the external communication with a strapping unit.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: strappingStatus
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"strappingStatus",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"good",
"(",
"0",
")",
",",
"communicationLost",
"(",
"1",
")",
"}",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"Status of the external communication with a strapping unit.\"",
"::=",
"{",
"unitEntry",
"32",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"good",
0
],
[
"communicationLost",
1
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Status of the external communication with a strapping unit."
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: EATON-EPDU-MIB
See published definition above
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DateAndTime', 'DisplayString'], 'EATON-OIDS': ['pduAgent'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'NOTIFICATION-TYPE', 'MODULE-IDENTITY', 'Counter32', 'Unsigned32', 'Integer32', 'enterprises'], 'SNMPv2-CONF': ['NOTIFICATION-GROUP', 'OBJECT-GROUP', 'MODULE-COMPLIANCE']}Related source files and packages:
Vendor MIB copy from the Observium Community archive.
Module: EATON-EPDU-MIB
Same published definition (formatting differs; exact original is in the source file)
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DateAndTime', 'DisplayString'], 'EATON-OIDS': ['pduAgent'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'NOTIFICATION-TYPE', 'MODULE-IDENTITY', 'Counter32', 'Unsigned32', 'Integer32', 'enterprises'], 'SNMPv2-CONF': ['NOTIFICATION-GROUP', 'OBJECT-GROUP', 'MODULE-COMPLIANCE']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.534.6.6.7.1.2.1.1 | strappingIndex | 0 | 0 | For units that support 'strapping' functionality, this will be a unique value for each unit. If units do not support 'strapping… |
| 1.3.6.1.4.1.534.6.6.7.1.2.1.2 | productName | 0 | 0 | Name of the product. |
| 1.3.6.1.4.1.534.6.6.7.1.2.1.3 | partNumber | 0 | 0 | Part number of the unit. |
| 1.3.6.1.4.1.534.6.6.7.1.2.1.4 | serialNumber | 0 | 0 | Serial number of the unit. |
| 1.3.6.1.4.1.534.6.6.7.1.2.1.5 | firmwareVersion | 0 | 0 | Firmware version. |
| 1.3.6.1.4.1.534.6.6.7.1.2.1.6 | unitName | 0 | 0 | Descriptive name for the unit. |
| 1.3.6.1.4.1.534.6.6.7.1.2.1.7 | lcdControl | 0 | 0 | Control the local LCD. |
| 1.3.6.1.4.1.534.6.6.7.1.2.1.8 | clockValue | 0 | 0 | Clock value. This could be from either a real-time clock (in which case it is likely writeable) or from a time server via NTP (… |
| 1.3.6.1.4.1.534.6.6.7.1.2.1.9 | temperatureScale | 0 | 0 | Scale used to return temperature objects. |
| 1.3.6.1.4.1.534.6.6.7.1.2.1.10 | unitType | 0 | 0 | |
| 1.3.6.1.4.1.534.6.6.7.1.2.1.11 | systemType | 0 | 0 | |
| 1.3.6.1.4.1.534.6.6.7.1.2.1.20 | inputCount | 0 | 0 | Number of inputs on this ePDU. |
| 1.3.6.1.4.1.534.6.6.7.1.2.1.21 | groupCount | 0 | 0 | Number of groups on this ePDU. Groups include breakers, outlet sections, and user-defined groups. |
| 1.3.6.1.4.1.534.6.6.7.1.2.1.22 | outletCount | 0 | 0 | Number of outlets on this ePDU. |
| 1.3.6.1.4.1.534.6.6.7.1.2.1.23 | temperatureCount | 0 | 0 | Max number of temperature measurements on this ePDU. |
| 1.3.6.1.4.1.534.6.6.7.1.2.1.24 | humidityCount | 0 | 0 | Max number of humidity measurements on this ePDU. |
| 1.3.6.1.4.1.534.6.6.7.1.2.1.25 | contactCount | 0 | 0 | Max number of contact sensors on this ePDU. |
| 1.3.6.1.4.1.534.6.6.7.1.2.1.30 | communicationStatus | 0 | 0 | Status of the internal communication with the PDU. |
| 1.3.6.1.4.1.534.6.6.7.1.2.1.31 | internalStatus | 0 | 0 | Status of the internal failure inside the PDU. |
| 1.3.6.1.4.1.534.6.6.7.1.2.1.40 | userName | 0 | 0 | Username used to log into the PDU. |