losDetected

1.3.6.1.4.1.5395.4.1.2.0.5

Description

This trap indicates that the specified SONET/SDH port is experiencing a Loss of Signal (LOS) failure. Bellcore Document TA-NWT-000253 Section 6.3.1.1.1 states that a SONET/SDH Network Element should declare an LOS failure when the LOS defect persists for 2.5 +/- 0.5 seconds, or when an LOS defect is present and the cr…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.5395.4.1.2.0 (eciSonetTrapsZero)
Node code
5
Node name
losDetected
Category
SNMP notification
Numeric OID
1.3.6.1.4.1.5395.4.1.2.0.5
URN notation
urn:oid:1.3.6.1.4.1.5395.4.1.2.0.5
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 5395 4 1 2 0 5}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) eciMIB(5395) eciTraps(4) eciTrapsMIB(1) eciSonetTraps(2) eciSonetTrapsZero(0) losDetected(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) eciMIB(5395) eciTraps(4) eciTrapsMIB(1) eciSonetTraps(2) eciSonetTrapsZero(0) losDetected(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) eciMIB(5395) eciTraps(4) eciTrapsMIB(1) eciSonetTraps(2) eciSonetTrapsZero(0) losDetected(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) eciMIB(5395) eciTraps(4) eciTrapsMIB(1) eciSonetTraps(2) eciSonetTrapsZero(0) losDetected(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) eciMIB(5395) eciTraps(4) eciTrapsMIB(1) eciSonetTraps(2) eciSonetTrapsZero(0) losDetected(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) eciMIB(5395) eciTraps(4) eciTrapsMIB(1) eciSonetTraps(2) eciSonetTrapsZero(0) losDetected(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) eciMIB(5395) eciTraps(4) eciTrapsMIB(1) eciSonetTraps(2) eciSonetTrapsZero(0) losDetected(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) eciMIB(5395) eciTraps(4) eciTrapsMIB(1) eciSonetTraps(2) eciSonetTrapsZero(0) losDetected(5)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) eciMIB(5395) eciTraps(4) eciTrapsMIB(1) eciSonetTraps(2) eciSonetTrapsZero(0) losDetected(5)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) eciMIB(5395) eciTraps(4) eciTrapsMIB(1) eciSonetTraps(2) eciSonetTrapsZero(0) losDetected(5)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) eciMIB(5395) eciTraps(4) eciTrapsMIB(1) eciSonetTraps(2) eciSonetTrapsZero(0) losDetected(5)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) eciMIB(5395) eciTraps(4) eciTrapsMIB(1) eciSonetTraps(2) eciSonetTrapsZero(0) losDetected(5)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) eciMIB(5395) eciTraps(4) eciTrapsMIB(1) eciSonetTraps(2) eciSonetTrapsZero(0) losDetected(5)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) eciMIB(5395) eciTraps(4) eciTrapsMIB(1) eciSonetTraps(2) eciSonetTrapsZero(0) losDetected(5)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) eciMIB(5395) eciTraps(4) eciTrapsMIB(1) eciSonetTraps(2) eciSonetTrapsZero(0) losDetected(5)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) eciMIB(5395) eciTraps(4) eciTrapsMIB(1) eciSonetTraps(2) eciSonetTrapsZero(0) losDetected(5)}
OID-IRI notation
  • /1/3/6/1/4/1/5395/4/1/2/0/5
  • /ISO/Identified-Organization/6/1/4/1/5395/4/1/2/0/5
  • /ISO/3/6/1/4/1/5395/4/1/2/0/5
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/5395/eciTraps/eciTrapsMIB/eciSonetTraps/eciSonetTrapsZero/losDetected
  • /iso/identified-organization/dod/internet/private/enterprise/eciMIB/eciTraps/eciTrapsMIB/eciSonetTraps/eciSonetTrapsZero/losDetected
  • /iso/identified-organization/dod/internet/private/enterprises/5395/eciTraps/eciTrapsMIB/eciSonetTraps/eciSonetTrapsZero/losDetected
  • /iso/identified-organization/dod/internet/private/enterprises/eciMIB/eciTraps/eciTrapsMIB/eciSonetTraps/eciSonetTrapsZero/losDetected
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/5395/eciTraps/eciTrapsMIB/eciSonetTraps/eciSonetTrapsZero/losDetected
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/eciMIB/eciTraps/eciTrapsMIB/eciSonetTraps/eciSonetTrapsZero/losDetected
  • /iso/identified-organization/dod/internet/private/vendor-objects/5395/eciTraps/eciTrapsMIB/eciSonetTraps/eciSonetTrapsZero/losDetected
  • /iso/identified-organization/dod/internet/private/vendor-objects/eciMIB/eciTraps/eciTrapsMIB/eciSonetTraps/eciSonetTrapsZero/losDetected
  • /iso/org/dod/internet/private/enterprise/5395/eciTraps/eciTrapsMIB/eciSonetTraps/eciSonetTrapsZero/losDetected
  • /iso/org/dod/internet/private/enterprise/eciMIB/eciTraps/eciTrapsMIB/eciSonetTraps/eciSonetTrapsZero/losDetected
  • /iso/org/dod/internet/private/enterprises/5395/eciTraps/eciTrapsMIB/eciSonetTraps/eciSonetTrapsZero/losDetected
  • /iso/org/dod/internet/private/enterprises/eciMIB/eciTraps/eciTrapsMIB/eciSonetTraps/eciSonetTrapsZero/losDetected
  • /iso/org/dod/internet/private/ldap-enterprise/5395/eciTraps/eciTrapsMIB/eciSonetTraps/eciSonetTrapsZero/losDetected
  • /iso/org/dod/internet/private/ldap-enterprise/eciMIB/eciTraps/eciTrapsMIB/eciSonetTraps/eciSonetTrapsZero/losDetected
  • /iso/org/dod/internet/private/vendor-objects/5395/eciTraps/eciTrapsMIB/eciSonetTraps/eciSonetTrapsZero/losDetected
  • /iso/org/dod/internet/private/vendor-objects/eciMIB/eciTraps/eciTrapsMIB/eciSonetTraps/eciSonetTrapsZero/losDetected
  • Additional combinations skipped.

The displayed source records contain one distinct definition. Compare its source records.

losDetected NOTIFICATION-TYPE
	OBJECTS { ifIndex, ifName }
	STATUS  current
	DESCRIPTION
		"This trap indicates that the specified SONET/SDH port is
		experiencing a Loss of Signal (LOS) failure. Bellcore
		Document TA-NWT-000253 Section 6.3.1.1.1 states that a
		SONET/SDH Network Element should declare an LOS failure
		when the LOS defect persists for 2.5 +/- 0.5 seconds,
		or when an LOS defect is present and the criteria for
		a Loss of Frame (LOF) failure declaration have been met."
	REFERENCE
		"losCleared"
	::= { eciSonetTrapsZero 5 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

This trap indicates that the specified SONET/SDH port is experiencing a Loss of Signal (LOS) failure. Bellcore Document TA-NWT-000253 Section 6.3.1.1.1 states that a SONET/SDH Network Element should declare an LOS failure when the LOS defect persists for 2.5 +/- 0.5 seconds, or when an LOS defect is present and the criteria for a Loss of Frame (LOF) failure declaration have been met.

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 1

losDetected · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: losDetected

Technical details
{
  "smi_kind": "NOTIFICATION-TYPE",
  "definition": [
    "losDetected",
    "NOTIFICATION-TYPE",
    "OBJECTS",
    "{",
    "ifIndex",
    ",",
    "ifName",
    "}",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"This trap indicates that the specified SONET/SDH port is experiencing a Loss of Signal (LOS) failure. Bellcore Document TA-NWT-000253 Section 6.3.1.1.1 states that a SONET/SDH Network Element should declare an LOS failure when the LOS defect persists for 2.5 +/- 0.5 seconds, or when an LOS defect is present and the criteria for a Loss of Frame (LOF) failure declaration have been met.\"",
    "REFERENCE",
    "\"losCleared\"",
    "::=",
    "{",
    "eciSonetTrapsZero",
    "5",
    "}"
  ],
  "syntax_tree": [
    [
      "Objects",
      [
        "ifIndex",
        "ifName"
      ]
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "This trap indicates that the specified SONET/SDH port is experiencing a Loss of Signal (LOS) failure. Bellcore Document TA-NWT-000253 Section 6.3.1.1.1 states that a SONET/SDH Network Element should declare an LOS failure when the LOS defect persists for 2.5 +/- 0.5 seconds, or when an LOS defect is present and the criteria for a Loss of Frame (LOF) failure declaration have been met."
    ],
    [
      "REFERENCE",
      "losCleared"
    ]
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.5395)

Uppuluri Ramesh

Siblings (61)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.5395.4.1.2.0.1 sonetFacilityLoopbackConfigured00
1.3.6.1.4.1.5395.4.1.2.0.2 sonetFacilityLoopbackCleared00
1.3.6.1.4.1.5395.4.1.2.0.3 sonetTerminalLoopbackConfigured00
1.3.6.1.4.1.5395.4.1.2.0.4 sonetTerminalLoopbackCleared00
1.3.6.1.4.1.5395.4.1.2.0.6 losCleared00
1.3.6.1.4.1.5395.4.1.2.0.7 sonetLOFDetected00
1.3.6.1.4.1.5395.4.1.2.0.8 sonetLOFCleared00
1.3.6.1.4.1.5395.4.1.2.0.9 sonetLineAISDetected00
1.3.6.1.4.1.5395.4.1.2.0.10 sonetLineAISCleared00
1.3.6.1.4.1.5395.4.1.2.0.11 sonetLineRDIDetected00
1.3.6.1.4.1.5395.4.1.2.0.12 sonetLineRDICleared00
1.3.6.1.4.1.5395.4.1.2.0.13 sonetPathAISDetected00
1.3.6.1.4.1.5395.4.1.2.0.14 sonetPathAISCleared00
1.3.6.1.4.1.5395.4.1.2.0.15 sonetPathRDIDetected00
1.3.6.1.4.1.5395.4.1.2.0.16 sonetPathRDICleared00
1.3.6.1.4.1.5395.4.1.2.0.17 sonetPathLOPDetected00
1.3.6.1.4.1.5395.4.1.2.0.18 sonetPathLOPCleared00
1.3.6.1.4.1.5395.4.1.2.0.19 sonetPathLabelDetected00
1.3.6.1.4.1.5395.4.1.2.0.20 sonetPathLabelCleared00
1.3.6.1.4.1.5395.4.1.2.0.21 sonetPathUNEQDetected00
1.3.6.1.4.1.5395.4.1.2.0.22 sonetPathUNEQCleared00
1.3.6.1.4.1.5395.4.1.2.0.24 sonetBerSfDetected00
1.3.6.1.4.1.5395.4.1.2.0.25 sonetBerSfCleared00
1.3.6.1.4.1.5395.4.1.2.0.26 sonetBerSdDetected00
1.3.6.1.4.1.5395.4.1.2.0.27 sonetBerSdCleared00
1.3.6.1.4.1.5395.4.1.2.0.28 sonetPathLOMDetected00
1.3.6.1.4.1.5395.4.1.2.0.29 sonetPathLOMCleared00
1.3.6.1.4.1.5395.4.1.2.0.30 sonetPathRDIServerDetected00
1.3.6.1.4.1.5395.4.1.2.0.31 sonetPathRDIServerCleared00
1.3.6.1.4.1.5395.4.1.2.0.32 sonetPathRDIPayloadDetected00
1.3.6.1.4.1.5395.4.1.2.0.33 sonetPathRDIPayloadCleared00
1.3.6.1.4.1.5395.4.1.2.0.34 sonetPathRDIConnectivityDetected00
1.3.6.1.4.1.5395.4.1.2.0.35 sonetPathRDIConnectivityCleared00
1.3.6.1.4.1.5395.4.1.2.0.36 sdhMSRDIDetected00
1.3.6.1.4.1.5395.4.1.2.0.37 sdhMSRDICleared00
1.3.6.1.4.1.5395.4.1.2.0.38 sdhMSBerSfDetected00
1.3.6.1.4.1.5395.4.1.2.0.39 sdhMSBerSfCleared00
1.3.6.1.4.1.5395.4.1.2.0.40 sdhMSBerSdDetected00
1.3.6.1.4.1.5395.4.1.2.0.41 sdhMSBerSdCleared00
1.3.6.1.4.1.5395.4.1.2.0.42 sdhMSAISDetected00
1.3.6.1.4.1.5395.4.1.2.0.43 sdhMSAISCleared00
1.3.6.1.4.1.5395.4.1.2.0.44 sdhRSLOFDetected00
1.3.6.1.4.1.5395.4.1.2.0.45 sdhRSLOFCleared00
1.3.6.1.4.1.5395.4.1.2.0.46 sdhHOPathAISDetected00
1.3.6.1.4.1.5395.4.1.2.0.47 sdhHOPathAISCleared00
1.3.6.1.4.1.5395.4.1.2.0.48 sdhHOPathRDIDetected00
1.3.6.1.4.1.5395.4.1.2.0.49 sdhHOPathRDICleared00
1.3.6.1.4.1.5395.4.1.2.0.50 sdhHOPathLOPDetected00
1.3.6.1.4.1.5395.4.1.2.0.51 sdhHOPathLOPCleared00
1.3.6.1.4.1.5395.4.1.2.0.52 sdhHOPathLabelDetected00