ups12FullCompliance — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
The compliance statement for UPSs that support advanced full-featured functions.
{1 3 6 1 4 1 53973 1 1 13 3 1 3}
The compliance statement for UPSs that support advanced full-featured functions.
Status in source: current.
Names: ups12FullCompliance
{
"smi_kind": "MODULE-COMPLIANCE",
"definition": [
"ups12FullCompliance",
"MODULE-COMPLIANCE",
"STATUS",
"current",
"DESCRIPTION",
"\"The compliance statement for UPSs that support advanced full-featured functions.\"",
"MODULE",
"MANDATORY-GROUPS",
"{",
"ups12FullIdentGroup",
",",
"ups12FullBatteryGroup",
",",
"ups12FullInputGroup",
",",
"ups12FullOutputGroup",
",",
"ups12FullAlarmGroup",
",",
"ups12FullTestGroup",
",",
"ups12FullControlGroup",
"}",
"OBJECT",
"ups12AlarmDescr",
"DESCRIPTION",
"\"Support of all `well known' alarm types is not required. The well known alarm types which must be supported are: ups12AlarmBatteryBad, ups12AlarmOnBattery, ups12AlarmLowBattery, ups12AlarmDepletedBattery, ups12AlarmTempBad, ups12AlarmInputBad, ups12AlarmOnBypass, ups12AlarmBypassBad, ups12AlarmOutputOffAsRequested, ups12AlarmUpsOffAsRequested, ups12AlarmUpsOutputOff, ups12AlarmUpsSystemOff, ups12AlarmGeneralFault, ups12AlarmDiagnosticTestFailed, ups12AlarmCommunicationsLost, ups12AlarmShutdownPending, and ups12AlarmTestInProgress.\"",
"OBJECT",
"ups12TestId",
"DESCRIPTION",
"\"Support of all `well known' test types is not required. The well known test types which must be supported are: ups12TestNoTestsInitiated, ups12TestGeneralSystemsTest, and ups12TestQuickBatteryTest.\"",
"OBJECT",
"ups12OutputSource",
"SYNTAX",
"INTEGER",
"{",
"normal",
"(",
"2",
")",
",",
"battery",
"(",
"4",
")",
"}",
"DESCRIPTION",
"\"Support of the values other(1), none(2), bypass(4), booster(6) and reducer(7) is not required.\"",
"GROUP",
"ups12FullBypassGroup",
"DESCRIPTION",
"\"The ups12FullBypassGroup is only required for UPSs that have a Bypass present.\"",
"OBJECT",
"ups12ShutdownType",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Read-write access is not required, i.e., compliant systems need not support more than one shutdown type.\"",
"::=",
"{",
"ups12Compliances",
"3",
"}"
],
"syntax_tree": [
[
"Status",
"current"
],
[
"DESCRIPTION",
"The compliance statement for UPSs that support advanced full-featured functions."
],
null,
[
"ComplianceModules",
[
[
null,
[
"ups12FullIdentGroup",
"ups12FullBatteryGroup",
"ups12FullInputGroup",
"ups12FullOutputGroup",
"ups12FullAlarmGroup",
"ups12FullTestGroup",
"ups12FullControlGroup"
]
]
]
]
]
}Vendor MIB copy from the LibreNMS archive.
Module: ABBMODULARUPS-MIB
ups12FullCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for UPSs that support
advanced full-featured functions."
MODULE -- this module
MANDATORY-GROUPS { ups12FullIdentGroup, ups12FullBatteryGroup,
ups12FullInputGroup, ups12FullOutputGroup,
ups12FullAlarmGroup, ups12FullTestGroup,
ups12FullControlGroup }
OBJECT ups12AlarmDescr
DESCRIPTION
"Support of all `well known' alarm types is not
required. The well known alarm types which must be
supported are: ups12AlarmBatteryBad, ups12AlarmOnBattery,
ups12AlarmLowBattery, ups12AlarmDepletedBattery,
ups12AlarmTempBad, ups12AlarmInputBad, ups12AlarmOnBypass,
ups12AlarmBypassBad, ups12AlarmOutputOffAsRequested,
ups12AlarmUpsOffAsRequested, ups12AlarmUpsOutputOff,
ups12AlarmUpsSystemOff, ups12AlarmGeneralFault,
ups12AlarmDiagnosticTestFailed,
ups12AlarmCommunicationsLost, ups12AlarmShutdownPending,
and ups12AlarmTestInProgress."
OBJECT ups12TestId
DESCRIPTION
"Support of all `well known' test types is not
required. The well known test types which must be
supported are: ups12TestNoTestsInitiated,
ups12TestGeneralSystemsTest, and
ups12TestQuickBatteryTest."
OBJECT ups12OutputSource
SYNTAX INTEGER {
normal(2),
battery(4)
}
DESCRIPTION
"Support of the values other(1), none(2), bypass(4),
booster(6) and reducer(7) is not required."
GROUP ups12FullBypassGroup
DESCRIPTION
"The ups12FullBypassGroup is only required for UPSs that
have a Bypass present."
OBJECT ups12ShutdownType
MIN-ACCESS read-only
DESCRIPTION
"Read-write access is not required, i.e., compliant
systems need not support more than one shutdown type."
::= { ups12Compliances 3 }{'SNMPv2-TC': ['DisplayString', 'TimeStamp', 'TimeInterval', 'TestAndIncr', 'AutonomousType', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'OBJECT-IDENTITY', 'Counter32', 'Gauge32', 'Integer32', 'Unsigned32', 'enterprises'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP']}Related source files and packages: