ups14BasicCompliance — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
The compliance statement for UPSs that support full-featured functions, such as control.
{1 3 6 1 4 1 53973 1 1 15 3 1 2}
The compliance statement for UPSs that support full-featured functions, such as control.
Status in source: current.
Names: ups14BasicCompliance
{
"smi_kind": "MODULE-COMPLIANCE",
"definition": [
"ups14BasicCompliance",
"MODULE-COMPLIANCE",
"STATUS",
"current",
"DESCRIPTION",
"\"The compliance statement for UPSs that support full-featured functions, such as control.\"",
"MODULE",
"MANDATORY-GROUPS",
"{",
"ups14BasicIdentGroup",
",",
"ups14BasicBatteryGroup",
",",
"ups14BasicInputGroup",
",",
"ups14BasicOutputGroup",
",",
"ups14BasicAlarmGroup",
",",
"ups14BasicTestGroup",
",",
"ups14BasicControlGroup",
"}",
"OBJECT",
"ups14AlarmDescr",
"DESCRIPTION",
"\"Support of all `well known' alarm types is not required. The well known alarm types which must be supported are: ups14AlarmOnBattery, ups14AlarmLowBattery, ups14AlarmDepletedBattery, ups14AlarmTempBad, ups14AlarmInputBad, ups14AlarmOutputOverload, ups14AlarmOnBypass, ups14AlarmBypassBad, ups14AlarmOutputOffAsRequested, ups14AlarmUpsOffAsRequested, ups14AlarmUpsOutputOff, ups14AlarmUpsSystemOff, ups14AlarmGeneralFault, ups14AlarmDiagnosticTestFailed, ups14AlarmCommunicationsLost, ups14AlarmShutdownPending, and ups14AlarmTestInProgress.\"",
"OBJECT",
"ups14TestId",
"DESCRIPTION",
"\"Support of all `well known' test types is not required. If no tests are supported, then the only well known test type which must be supported is ups14TestNoTestsInitiated.\"",
"OBJECT",
"ups14OutputSource",
"SYNTAX",
"INTEGER",
"{",
"normal",
"(",
"2",
")",
",",
"battery",
"(",
"4",
")",
"}",
"DESCRIPTION",
"\"Support of the values other(1), none(2), bypass(4), booster(6) and reducer(7) is not required.\"",
"GROUP",
"ups14BasicBypassGroup",
"DESCRIPTION",
"\"The ups14BasicBypassGroup is only required for UPSs that have a Bypass present.\"",
"OBJECT",
"ups14ShutdownType",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Read-write access is not required, i.e., compliant systems need not support more than one shutdown type.\"",
"::=",
"{",
"ups14Compliances",
"2",
"}"
],
"syntax_tree": [
[
"Status",
"current"
],
[
"DESCRIPTION",
"The compliance statement for UPSs that support full-featured functions, such as control."
],
null,
[
"ComplianceModules",
[
[
null,
[
"ups14BasicIdentGroup",
"ups14BasicBatteryGroup",
"ups14BasicInputGroup",
"ups14BasicOutputGroup",
"ups14BasicAlarmGroup",
"ups14BasicTestGroup",
"ups14BasicControlGroup"
]
]
]
]
]
}Vendor MIB copy from the LibreNMS archive.
Module: ABBMODULARUPS-MIB
ups14BasicCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for UPSs that support
full-featured functions, such as control."
MODULE -- this module
MANDATORY-GROUPS { ups14BasicIdentGroup,
ups14BasicBatteryGroup, ups14BasicInputGroup,
ups14BasicOutputGroup, ups14BasicAlarmGroup,
ups14BasicTestGroup, ups14BasicControlGroup }
OBJECT ups14AlarmDescr
DESCRIPTION
"Support of all `well known' alarm types is not
required. The well known alarm types which must be
supported are: ups14AlarmOnBattery, ups14AlarmLowBattery,
ups14AlarmDepletedBattery, ups14AlarmTempBad,
ups14AlarmInputBad, ups14AlarmOutputOverload,
ups14AlarmOnBypass, ups14AlarmBypassBad,
ups14AlarmOutputOffAsRequested,
ups14AlarmUpsOffAsRequested, ups14AlarmUpsOutputOff,
ups14AlarmUpsSystemOff, ups14AlarmGeneralFault,
ups14AlarmDiagnosticTestFailed,
ups14AlarmCommunicationsLost, ups14AlarmShutdownPending,
and ups14AlarmTestInProgress."
OBJECT ups14TestId
DESCRIPTION
"Support of all `well known' test types is not
required. If no tests are supported, then the only
well known test type which must be supported is
ups14TestNoTestsInitiated."
OBJECT ups14OutputSource
SYNTAX INTEGER {
normal(2),
battery(4)
}
DESCRIPTION
"Support of the values other(1), none(2), bypass(4),
booster(6) and reducer(7) is not required."
GROUP ups14BasicBypassGroup
DESCRIPTION
"The ups14BasicBypassGroup is only required for UPSs
that have a Bypass present."
OBJECT ups14ShutdownType
MIN-ACCESS read-only
DESCRIPTION
"Read-write access is not required, i.e., compliant
systems need not support more than one shutdown type."
::= { ups14Compliances 2 }{'SNMPv2-TC': ['DisplayString', 'TimeStamp', 'TimeInterval', 'TestAndIncr', 'AutonomousType', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'OBJECT-IDENTITY', 'Counter32', 'Gauge32', 'Integer32', 'Unsigned32', 'enterprises'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP']}Related source files and packages:
Downloaded: 2026-10-24T02:14:13.121331+00:00.
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.53973.1.1.15.3.1.1 | ups14SubsetCompliance | 0 | 0 | |
| 1.3.6.1.4.1.53973.1.1.15.3.1.3 | ups14FullCompliance | 0 | 0 |