ups15FullCompliance — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
The compliance statement for UPSs that support advanced full-featured functions.
{1 3 6 1 4 1 53973 1 1 16 3 1 3}
The compliance statement for UPSs that support advanced full-featured functions.
Status in source: current.
Names: ups15FullCompliance
{
"smi_kind": "MODULE-COMPLIANCE",
"definition": [
"ups15FullCompliance",
"MODULE-COMPLIANCE",
"STATUS",
"current",
"DESCRIPTION",
"\"The compliance statement for UPSs that support advanced full-featured functions.\"",
"MODULE",
"MANDATORY-GROUPS",
"{",
"ups15FullIdentGroup",
",",
"ups15FullBatteryGroup",
",",
"ups15FullInputGroup",
",",
"ups15FullOutputGroup",
",",
"ups15FullAlarmGroup",
",",
"ups15FullTestGroup",
",",
"ups15FullControlGroup",
"}",
"OBJECT",
"ups15AlarmDescr",
"DESCRIPTION",
"\"Support of all `well known' alarm types is not required. The well known alarm types which must be supported are: ups15AlarmBatteryBad, ups15AlarmOnBattery, ups15AlarmLowBattery, ups15AlarmDepletedBattery, ups15AlarmTempBad, ups15AlarmInputBad, ups15AlarmOnBypass, ups15AlarmBypassBad, ups15AlarmOutputOffAsRequested, ups15AlarmUpsOffAsRequested, ups15AlarmUpsOutputOff, ups15AlarmUpsSystemOff, ups15AlarmGeneralFault, ups15AlarmDiagnosticTestFailed, ups15AlarmCommunicationsLost, ups15AlarmShutdownPending, and ups15AlarmTestInProgress.\"",
"OBJECT",
"ups15TestId",
"DESCRIPTION",
"\"Support of all `well known' test types is not required. The well known test types which must be supported are: ups15TestNoTestsInitiated, ups15TestGeneralSystemsTest, and ups15TestQuickBatteryTest.\"",
"OBJECT",
"ups15OutputSource",
"SYNTAX",
"INTEGER",
"{",
"normal",
"(",
"2",
")",
",",
"battery",
"(",
"4",
")",
"}",
"DESCRIPTION",
"\"Support of the values other(1), none(2), bypass(4), booster(6) and reducer(7) is not required.\"",
"GROUP",
"ups15FullBypassGroup",
"DESCRIPTION",
"\"The ups15FullBypassGroup is only required for UPSs that have a Bypass present.\"",
"OBJECT",
"ups15ShutdownType",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Read-write access is not required, i.e., compliant systems need not support more than one shutdown type.\"",
"::=",
"{",
"ups15Compliances",
"3",
"}"
],
"syntax_tree": [
[
"Status",
"current"
],
[
"DESCRIPTION",
"The compliance statement for UPSs that support advanced full-featured functions."
],
null,
[
"ComplianceModules",
[
[
null,
[
"ups15FullIdentGroup",
"ups15FullBatteryGroup",
"ups15FullInputGroup",
"ups15FullOutputGroup",
"ups15FullAlarmGroup",
"ups15FullTestGroup",
"ups15FullControlGroup"
]
]
]
]
]
}Vendor MIB copy from the LibreNMS archive.
Module: ABBMODULARUPS-MIB
ups15FullCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for UPSs that support
advanced full-featured functions."
MODULE -- this module
MANDATORY-GROUPS { ups15FullIdentGroup, ups15FullBatteryGroup,
ups15FullInputGroup, ups15FullOutputGroup,
ups15FullAlarmGroup, ups15FullTestGroup,
ups15FullControlGroup }
OBJECT ups15AlarmDescr
DESCRIPTION
"Support of all `well known' alarm types is not
required. The well known alarm types which must be
supported are: ups15AlarmBatteryBad, ups15AlarmOnBattery,
ups15AlarmLowBattery, ups15AlarmDepletedBattery,
ups15AlarmTempBad, ups15AlarmInputBad, ups15AlarmOnBypass,
ups15AlarmBypassBad, ups15AlarmOutputOffAsRequested,
ups15AlarmUpsOffAsRequested, ups15AlarmUpsOutputOff,
ups15AlarmUpsSystemOff, ups15AlarmGeneralFault,
ups15AlarmDiagnosticTestFailed,
ups15AlarmCommunicationsLost, ups15AlarmShutdownPending,
and ups15AlarmTestInProgress."
OBJECT ups15TestId
DESCRIPTION
"Support of all `well known' test types is not
required. The well known test types which must be
supported are: ups15TestNoTestsInitiated,
ups15TestGeneralSystemsTest, and
ups15TestQuickBatteryTest."
OBJECT ups15OutputSource
SYNTAX INTEGER {
normal(2),
battery(4)
}
DESCRIPTION
"Support of the values other(1), none(2), bypass(4),
booster(6) and reducer(7) is not required."
GROUP ups15FullBypassGroup
DESCRIPTION
"The ups15FullBypassGroup is only required for UPSs that
have a Bypass present."
OBJECT ups15ShutdownType
MIN-ACCESS read-only
DESCRIPTION
"Read-write access is not required, i.e., compliant
systems need not support more than one shutdown type."
::= { ups15Compliances 3 }{'SNMPv2-TC': ['DisplayString', 'TimeStamp', 'TimeInterval', 'TestAndIncr', 'AutonomousType', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'OBJECT-IDENTITY', 'Counter32', 'Gauge32', 'Integer32', 'Unsigned32', 'enterprises'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP']}Related source files and packages: