ups16FullCompliance — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
The compliance statement for UPSs that support advanced full-featured functions.
{1 3 6 1 4 1 53973 1 1 17 3 1 3}
The compliance statement for UPSs that support advanced full-featured functions.
Status in source: current.
Names: ups16FullCompliance
{
"smi_kind": "MODULE-COMPLIANCE",
"definition": [
"ups16FullCompliance",
"MODULE-COMPLIANCE",
"STATUS",
"current",
"DESCRIPTION",
"\"The compliance statement for UPSs that support advanced full-featured functions.\"",
"MODULE",
"MANDATORY-GROUPS",
"{",
"ups16FullIdentGroup",
",",
"ups16FullBatteryGroup",
",",
"ups16FullInputGroup",
",",
"ups16FullOutputGroup",
",",
"ups16FullAlarmGroup",
",",
"ups16FullTestGroup",
",",
"ups16FullControlGroup",
"}",
"OBJECT",
"ups16AlarmDescr",
"DESCRIPTION",
"\"Support of all `well known' alarm types is not required. The well known alarm types which must be supported are: ups16AlarmBatteryBad, ups16AlarmOnBattery, ups16AlarmLowBattery, ups16AlarmDepletedBattery, ups16AlarmTempBad, ups16AlarmInputBad, ups16AlarmOnBypass, ups16AlarmBypassBad, ups16AlarmOutputOffAsRequested, ups16AlarmUpsOffAsRequested, ups16AlarmUpsOutputOff, ups16AlarmUpsSystemOff, ups16AlarmGeneralFault, ups16AlarmDiagnosticTestFailed, ups16AlarmCommunicationsLost, ups16AlarmShutdownPending, and ups16AlarmTestInProgress.\"",
"OBJECT",
"ups16TestId",
"DESCRIPTION",
"\"Support of all `well known' test types is not required. The well known test types which must be supported are: ups16TestNoTestsInitiated, ups16TestGeneralSystemsTest, and ups16TestQuickBatteryTest.\"",
"OBJECT",
"ups16OutputSource",
"SYNTAX",
"INTEGER",
"{",
"normal",
"(",
"2",
")",
",",
"battery",
"(",
"4",
")",
"}",
"DESCRIPTION",
"\"Support of the values other(1), none(2), bypass(4), booster(6) and reducer(7) is not required.\"",
"GROUP",
"ups16FullBypassGroup",
"DESCRIPTION",
"\"The ups16FullBypassGroup is only required for UPSs that have a Bypass present.\"",
"OBJECT",
"ups16ShutdownType",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Read-write access is not required, i.e., compliant systems need not support more than one shutdown type.\"",
"::=",
"{",
"ups16Compliances",
"3",
"}"
],
"syntax_tree": [
[
"Status",
"current"
],
[
"DESCRIPTION",
"The compliance statement for UPSs that support advanced full-featured functions."
],
null,
[
"ComplianceModules",
[
[
null,
[
"ups16FullIdentGroup",
"ups16FullBatteryGroup",
"ups16FullInputGroup",
"ups16FullOutputGroup",
"ups16FullAlarmGroup",
"ups16FullTestGroup",
"ups16FullControlGroup"
]
]
]
]
]
}Vendor MIB copy from the LibreNMS archive.
Module: ABBMODULARUPS-MIB
ups16FullCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for UPSs that support
advanced full-featured functions."
MODULE -- this module
MANDATORY-GROUPS { ups16FullIdentGroup, ups16FullBatteryGroup,
ups16FullInputGroup, ups16FullOutputGroup,
ups16FullAlarmGroup, ups16FullTestGroup,
ups16FullControlGroup }
OBJECT ups16AlarmDescr
DESCRIPTION
"Support of all `well known' alarm types is not
required. The well known alarm types which must be
supported are: ups16AlarmBatteryBad, ups16AlarmOnBattery,
ups16AlarmLowBattery, ups16AlarmDepletedBattery,
ups16AlarmTempBad, ups16AlarmInputBad, ups16AlarmOnBypass,
ups16AlarmBypassBad, ups16AlarmOutputOffAsRequested,
ups16AlarmUpsOffAsRequested, ups16AlarmUpsOutputOff,
ups16AlarmUpsSystemOff, ups16AlarmGeneralFault,
ups16AlarmDiagnosticTestFailed,
ups16AlarmCommunicationsLost, ups16AlarmShutdownPending,
and ups16AlarmTestInProgress."
OBJECT ups16TestId
DESCRIPTION
"Support of all `well known' test types is not
required. The well known test types which must be
supported are: ups16TestNoTestsInitiated,
ups16TestGeneralSystemsTest, and
ups16TestQuickBatteryTest."
OBJECT ups16OutputSource
SYNTAX INTEGER {
normal(2),
battery(4)
}
DESCRIPTION
"Support of the values other(1), none(2), bypass(4),
booster(6) and reducer(7) is not required."
GROUP ups16FullBypassGroup
DESCRIPTION
"The ups16FullBypassGroup is only required for UPSs that
have a Bypass present."
OBJECT ups16ShutdownType
MIN-ACCESS read-only
DESCRIPTION
"Read-write access is not required, i.e., compliant
systems need not support more than one shutdown type."
::= { ups16Compliances 3 }{'SNMPv2-TC': ['DisplayString', 'TimeStamp', 'TimeInterval', 'TestAndIncr', 'AutonomousType', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'OBJECT-IDENTITY', 'Counter32', 'Gauge32', 'Integer32', 'Unsigned32', 'enterprises'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP']}Related source files and packages: