ups18FullCompliance — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
The compliance statement for UPSs that support advanced full-featured functions.
{1 3 6 1 4 1 53973 1 1 19 3 1 3}
The compliance statement for UPSs that support advanced full-featured functions.
Status in source: current.
Names: ups18FullCompliance
{
"smi_kind": "MODULE-COMPLIANCE",
"definition": [
"ups18FullCompliance",
"MODULE-COMPLIANCE",
"STATUS",
"current",
"DESCRIPTION",
"\"The compliance statement for UPSs that support advanced full-featured functions.\"",
"MODULE",
"MANDATORY-GROUPS",
"{",
"ups18FullIdentGroup",
",",
"ups18FullBatteryGroup",
",",
"ups18FullInputGroup",
",",
"ups18FullOutputGroup",
",",
"ups18FullAlarmGroup",
",",
"ups18FullTestGroup",
",",
"ups18FullControlGroup",
"}",
"OBJECT",
"ups18AlarmDescr",
"DESCRIPTION",
"\"Support of all `well known' alarm types is not required. The well known alarm types which must be supported are: ups18AlarmBatteryBad, ups18AlarmOnBattery, ups18AlarmLowBattery, ups18AlarmDepletedBattery, ups18AlarmTempBad, ups18AlarmInputBad, ups18AlarmOnBypass, ups18AlarmBypassBad, ups18AlarmOutputOffAsRequested, ups18AlarmUpsOffAsRequested, ups18AlarmUpsOutputOff, ups18AlarmUpsSystemOff, ups18AlarmGeneralFault, ups18AlarmDiagnosticTestFailed, ups18AlarmCommunicationsLost, ups18AlarmShutdownPending, and ups18AlarmTestInProgress.\"",
"OBJECT",
"ups18TestId",
"DESCRIPTION",
"\"Support of all `well known' test types is not required. The well known test types which must be supported are: ups18TestNoTestsInitiated, ups18TestGeneralSystemsTest, and ups18TestQuickBatteryTest.\"",
"OBJECT",
"ups18OutputSource",
"SYNTAX",
"INTEGER",
"{",
"normal",
"(",
"2",
")",
",",
"battery",
"(",
"4",
")",
"}",
"DESCRIPTION",
"\"Support of the values other(1), none(2), bypass(4), booster(6) and reducer(7) is not required.\"",
"GROUP",
"ups18FullBypassGroup",
"DESCRIPTION",
"\"The ups18FullBypassGroup is only required for UPSs that have a Bypass present.\"",
"OBJECT",
"ups18ShutdownType",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Read-write access is not required, i.e., compliant systems need not support more than one shutdown type.\"",
"::=",
"{",
"ups18Compliances",
"3",
"}"
],
"syntax_tree": [
[
"Status",
"current"
],
[
"DESCRIPTION",
"The compliance statement for UPSs that support advanced full-featured functions."
],
null,
[
"ComplianceModules",
[
[
null,
[
"ups18FullIdentGroup",
"ups18FullBatteryGroup",
"ups18FullInputGroup",
"ups18FullOutputGroup",
"ups18FullAlarmGroup",
"ups18FullTestGroup",
"ups18FullControlGroup"
]
]
]
]
]
}Vendor MIB copy from the LibreNMS archive.
Module: ABBMODULARUPS-MIB
ups18FullCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for UPSs that support
advanced full-featured functions."
MODULE -- this module
MANDATORY-GROUPS { ups18FullIdentGroup, ups18FullBatteryGroup,
ups18FullInputGroup, ups18FullOutputGroup,
ups18FullAlarmGroup, ups18FullTestGroup,
ups18FullControlGroup }
OBJECT ups18AlarmDescr
DESCRIPTION
"Support of all `well known' alarm types is not
required. The well known alarm types which must be
supported are: ups18AlarmBatteryBad, ups18AlarmOnBattery,
ups18AlarmLowBattery, ups18AlarmDepletedBattery,
ups18AlarmTempBad, ups18AlarmInputBad, ups18AlarmOnBypass,
ups18AlarmBypassBad, ups18AlarmOutputOffAsRequested,
ups18AlarmUpsOffAsRequested, ups18AlarmUpsOutputOff,
ups18AlarmUpsSystemOff, ups18AlarmGeneralFault,
ups18AlarmDiagnosticTestFailed,
ups18AlarmCommunicationsLost, ups18AlarmShutdownPending,
and ups18AlarmTestInProgress."
OBJECT ups18TestId
DESCRIPTION
"Support of all `well known' test types is not
required. The well known test types which must be
supported are: ups18TestNoTestsInitiated,
ups18TestGeneralSystemsTest, and
ups18TestQuickBatteryTest."
OBJECT ups18OutputSource
SYNTAX INTEGER {
normal(2),
battery(4)
}
DESCRIPTION
"Support of the values other(1), none(2), bypass(4),
booster(6) and reducer(7) is not required."
GROUP ups18FullBypassGroup
DESCRIPTION
"The ups18FullBypassGroup is only required for UPSs that
have a Bypass present."
OBJECT ups18ShutdownType
MIN-ACCESS read-only
DESCRIPTION
"Read-write access is not required, i.e., compliant
systems need not support more than one shutdown type."
::= { ups18Compliances 3 }{'SNMPv2-TC': ['DisplayString', 'TimeStamp', 'TimeInterval', 'TestAndIncr', 'AutonomousType', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'OBJECT-IDENTITY', 'Counter32', 'Gauge32', 'Integer32', 'Unsigned32', 'enterprises'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP']}Related source files and packages:
Downloaded: 2026-10-24T02:14:13.121331+00:00.
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.53973.1.1.19.3.1.1 | ups18SubsetCompliance | 0 | 0 | |
| 1.3.6.1.4.1.53973.1.1.19.3.1.2 | ups18BasicCompliance | 0 | 0 |