ups01FullCompliance — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
The compliance statement for UPSs that support advanced full-featured functions.
{1 3 6 1 4 1 53973 1 1 2 3 1 3}
The compliance statement for UPSs that support advanced full-featured functions.
Status in source: current.
Names: ups01FullCompliance
{
"smi_kind": "MODULE-COMPLIANCE",
"definition": [
"ups01FullCompliance",
"MODULE-COMPLIANCE",
"STATUS",
"current",
"DESCRIPTION",
"\"The compliance statement for UPSs that support advanced full-featured functions.\"",
"MODULE",
"MANDATORY-GROUPS",
"{",
"ups01FullIdentGroup",
",",
"ups01FullBatteryGroup",
",",
"ups01FullInputGroup",
",",
"ups01FullOutputGroup",
",",
"ups01FullAlarmGroup",
",",
"ups01FullTestGroup",
",",
"ups01FullControlGroup",
"}",
"OBJECT",
"ups01AlarmDescr",
"DESCRIPTION",
"\"Support of all `well known' alarm types is not required. The well known alarm types which must be supported are: ups01AlarmBatteryBad, ups01AlarmOnBattery, ups01AlarmLowBattery, ups01AlarmDepletedBattery, ups01AlarmTempBad, ups01AlarmInputBad, ups01AlarmOnBypass, ups01AlarmBypassBad, ups01AlarmOutputOffAsRequested, ups01AlarmUpsOffAsRequested, ups01AlarmUpsOutputOff, ups01AlarmUpsSystemOff, ups01AlarmGeneralFault, ups01AlarmDiagnosticTestFailed, ups01AlarmCommunicationsLost, ups01AlarmShutdownPending, and ups01AlarmTestInProgress.\"",
"OBJECT",
"ups01TestId",
"DESCRIPTION",
"\"Support of all `well known' test types is not required. The well known test types which must be supported are: ups01TestNoTestsInitiated, ups01TestGeneralSystemsTest, and ups01TestQuickBatteryTest.\"",
"OBJECT",
"ups01OutputSource",
"SYNTAX",
"INTEGER",
"{",
"normal",
"(",
"2",
")",
",",
"battery",
"(",
"4",
")",
"}",
"DESCRIPTION",
"\"Support of the values other(1), none(2), bypass(4), booster(6) and reducer(7) is not required.\"",
"GROUP",
"ups01FullBypassGroup",
"DESCRIPTION",
"\"The ups01FullBypassGroup is only required for UPSs that have a Bypass present.\"",
"OBJECT",
"ups01ShutdownType",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Read-write access is not required, i.e., compliant systems need not support more than one shutdown type.\"",
"::=",
"{",
"ups01Compliances",
"3",
"}"
],
"syntax_tree": [
[
"Status",
"current"
],
[
"DESCRIPTION",
"The compliance statement for UPSs that support advanced full-featured functions."
],
null,
[
"ComplianceModules",
[
[
null,
[
"ups01FullIdentGroup",
"ups01FullBatteryGroup",
"ups01FullInputGroup",
"ups01FullOutputGroup",
"ups01FullAlarmGroup",
"ups01FullTestGroup",
"ups01FullControlGroup"
]
]
]
]
]
}Vendor MIB copy from the LibreNMS archive.
Module: ABBMODULARUPS-MIB
ups01FullCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for UPSs that support
advanced full-featured functions."
MODULE -- this module
MANDATORY-GROUPS { ups01FullIdentGroup, ups01FullBatteryGroup,
ups01FullInputGroup, ups01FullOutputGroup,
ups01FullAlarmGroup, ups01FullTestGroup,
ups01FullControlGroup }
OBJECT ups01AlarmDescr
DESCRIPTION
"Support of all `well known' alarm types is not
required. The well known alarm types which must be
supported are: ups01AlarmBatteryBad, ups01AlarmOnBattery,
ups01AlarmLowBattery, ups01AlarmDepletedBattery,
ups01AlarmTempBad, ups01AlarmInputBad, ups01AlarmOnBypass,
ups01AlarmBypassBad, ups01AlarmOutputOffAsRequested,
ups01AlarmUpsOffAsRequested, ups01AlarmUpsOutputOff,
ups01AlarmUpsSystemOff, ups01AlarmGeneralFault,
ups01AlarmDiagnosticTestFailed,
ups01AlarmCommunicationsLost, ups01AlarmShutdownPending,
and ups01AlarmTestInProgress."
OBJECT ups01TestId
DESCRIPTION
"Support of all `well known' test types is not
required. The well known test types which must be
supported are: ups01TestNoTestsInitiated,
ups01TestGeneralSystemsTest, and
ups01TestQuickBatteryTest."
OBJECT ups01OutputSource
SYNTAX INTEGER {
normal(2),
battery(4)
}
DESCRIPTION
"Support of the values other(1), none(2), bypass(4),
booster(6) and reducer(7) is not required."
GROUP ups01FullBypassGroup
DESCRIPTION
"The ups01FullBypassGroup is only required for UPSs that
have a Bypass present."
OBJECT ups01ShutdownType
MIN-ACCESS read-only
DESCRIPTION
"Read-write access is not required, i.e., compliant
systems need not support more than one shutdown type."
::= { ups01Compliances 3 }{'SNMPv2-TC': ['DisplayString', 'TimeStamp', 'TimeInterval', 'TestAndIncr', 'AutonomousType', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'OBJECT-IDENTITY', 'Counter32', 'Gauge32', 'Integer32', 'Unsigned32', 'enterprises'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP']}Related source files and packages: