ups27BasicCompliance — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
The compliance statement for UPSs that support full-featured functions, such as control.
{1 3 6 1 4 1 53973 1 1 28 3 1 2}
The compliance statement for UPSs that support full-featured functions, such as control.
Status in source: current.
Names: ups27BasicCompliance
{
"smi_kind": "MODULE-COMPLIANCE",
"definition": [
"ups27BasicCompliance",
"MODULE-COMPLIANCE",
"STATUS",
"current",
"DESCRIPTION",
"\"The compliance statement for UPSs that support full-featured functions, such as control.\"",
"MODULE",
"MANDATORY-GROUPS",
"{",
"ups27BasicIdentGroup",
",",
"ups27BasicBatteryGroup",
",",
"ups27BasicInputGroup",
",",
"ups27BasicOutputGroup",
",",
"ups27BasicAlarmGroup",
",",
"ups27BasicTestGroup",
",",
"ups27BasicControlGroup",
"}",
"OBJECT",
"ups27AlarmDescr",
"DESCRIPTION",
"\"Support of all `well known' alarm types is not required. The well known alarm types which must be supported are: ups27AlarmOnBattery, ups27AlarmLowBattery, ups27AlarmDepletedBattery, ups27AlarmTempBad, ups27AlarmInputBad, ups27AlarmOutputOverload, ups27AlarmOnBypass, ups27AlarmBypassBad, ups27AlarmOutputOffAsRequested, ups27AlarmUpsOffAsRequested, ups27AlarmUpsOutputOff, ups27AlarmUpsSystemOff, ups27AlarmGeneralFault, ups27AlarmDiagnosticTestFailed, ups27AlarmCommunicationsLost, ups27AlarmShutdownPending, and ups27AlarmTestInProgress.\"",
"OBJECT",
"ups27TestId",
"DESCRIPTION",
"\"Support of all `well known' test types is not required. If no tests are supported, then the only well known test type which must be supported is ups27TestNoTestsInitiated.\"",
"OBJECT",
"ups27OutputSource",
"SYNTAX",
"INTEGER",
"{",
"normal",
"(",
"2",
")",
",",
"battery",
"(",
"4",
")",
"}",
"DESCRIPTION",
"\"Support of the values other(1), none(2), bypass(4), booster(6) and reducer(7) is not required.\"",
"GROUP",
"ups27BasicBypassGroup",
"DESCRIPTION",
"\"The ups27BasicBypassGroup is only required for UPSs that have a Bypass present.\"",
"OBJECT",
"ups27ShutdownType",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Read-write access is not required, i.e., compliant systems need not support more than one shutdown type.\"",
"::=",
"{",
"ups27Compliances",
"2",
"}"
],
"syntax_tree": [
[
"Status",
"current"
],
[
"DESCRIPTION",
"The compliance statement for UPSs that support full-featured functions, such as control."
],
null,
[
"ComplianceModules",
[
[
null,
[
"ups27BasicIdentGroup",
"ups27BasicBatteryGroup",
"ups27BasicInputGroup",
"ups27BasicOutputGroup",
"ups27BasicAlarmGroup",
"ups27BasicTestGroup",
"ups27BasicControlGroup"
]
]
]
]
]
}Vendor MIB copy from the LibreNMS archive.
Module: ABBMODULARUPS-MIB
ups27BasicCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for UPSs that support
full-featured functions, such as control."
MODULE -- this module
MANDATORY-GROUPS { ups27BasicIdentGroup,
ups27BasicBatteryGroup, ups27BasicInputGroup,
ups27BasicOutputGroup, ups27BasicAlarmGroup,
ups27BasicTestGroup, ups27BasicControlGroup }
OBJECT ups27AlarmDescr
DESCRIPTION
"Support of all `well known' alarm types is not
required. The well known alarm types which must be
supported are: ups27AlarmOnBattery, ups27AlarmLowBattery,
ups27AlarmDepletedBattery, ups27AlarmTempBad,
ups27AlarmInputBad, ups27AlarmOutputOverload,
ups27AlarmOnBypass, ups27AlarmBypassBad,
ups27AlarmOutputOffAsRequested,
ups27AlarmUpsOffAsRequested, ups27AlarmUpsOutputOff,
ups27AlarmUpsSystemOff, ups27AlarmGeneralFault,
ups27AlarmDiagnosticTestFailed,
ups27AlarmCommunicationsLost, ups27AlarmShutdownPending,
and ups27AlarmTestInProgress."
OBJECT ups27TestId
DESCRIPTION
"Support of all `well known' test types is not
required. If no tests are supported, then the only
well known test type which must be supported is
ups27TestNoTestsInitiated."
OBJECT ups27OutputSource
SYNTAX INTEGER {
normal(2),
battery(4)
}
DESCRIPTION
"Support of the values other(1), none(2), bypass(4),
booster(6) and reducer(7) is not required."
GROUP ups27BasicBypassGroup
DESCRIPTION
"The ups27BasicBypassGroup is only required for UPSs
that have a Bypass present."
OBJECT ups27ShutdownType
MIN-ACCESS read-only
DESCRIPTION
"Read-write access is not required, i.e., compliant
systems need not support more than one shutdown type."
::= { ups27Compliances 2 }{'SNMPv2-TC': ['DisplayString', 'TimeStamp', 'TimeInterval', 'TestAndIncr', 'AutonomousType', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'OBJECT-IDENTITY', 'Counter32', 'Gauge32', 'Integer32', 'Unsigned32', 'enterprises'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP']}Related source files and packages: