ups28FullCompliance — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
The compliance statement for UPSs that support advanced full-featured functions.
{1 3 6 1 4 1 53973 1 1 29 3 1 3}
The compliance statement for UPSs that support advanced full-featured functions.
Status in source: current.
Names: ups28FullCompliance
{
"smi_kind": "MODULE-COMPLIANCE",
"definition": [
"ups28FullCompliance",
"MODULE-COMPLIANCE",
"STATUS",
"current",
"DESCRIPTION",
"\"The compliance statement for UPSs that support advanced full-featured functions.\"",
"MODULE",
"MANDATORY-GROUPS",
"{",
"ups28FullIdentGroup",
",",
"ups28FullBatteryGroup",
",",
"ups28FullInputGroup",
",",
"ups28FullOutputGroup",
",",
"ups28FullAlarmGroup",
",",
"ups28FullTestGroup",
",",
"ups28FullControlGroup",
"}",
"OBJECT",
"ups28AlarmDescr",
"DESCRIPTION",
"\"Support of all `well known' alarm types is not required. The well known alarm types which must be supported are: ups28AlarmBatteryBad, ups28AlarmOnBattery, ups28AlarmLowBattery, ups28AlarmDepletedBattery, ups28AlarmTempBad, ups28AlarmInputBad, ups28AlarmOnBypass, ups28AlarmBypassBad, ups28AlarmOutputOffAsRequested, ups28AlarmUpsOffAsRequested, ups28AlarmUpsOutputOff, ups28AlarmUpsSystemOff, ups28AlarmGeneralFault, ups28AlarmDiagnosticTestFailed, ups28AlarmCommunicationsLost, ups28AlarmShutdownPending, and ups28AlarmTestInProgress.\"",
"OBJECT",
"ups28TestId",
"DESCRIPTION",
"\"Support of all `well known' test types is not required. The well known test types which must be supported are: ups28TestNoTestsInitiated, ups28TestGeneralSystemsTest, and ups28TestQuickBatteryTest.\"",
"OBJECT",
"ups28OutputSource",
"SYNTAX",
"INTEGER",
"{",
"normal",
"(",
"2",
")",
",",
"battery",
"(",
"4",
")",
"}",
"DESCRIPTION",
"\"Support of the values other(1), none(2), bypass(4), booster(6) and reducer(7) is not required.\"",
"GROUP",
"ups28FullBypassGroup",
"DESCRIPTION",
"\"The ups28FullBypassGroup is only required for UPSs that have a Bypass present.\"",
"OBJECT",
"ups28ShutdownType",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Read-write access is not required, i.e., compliant systems need not support more than one shutdown type.\"",
"::=",
"{",
"ups28Compliances",
"3",
"}"
],
"syntax_tree": [
[
"Status",
"current"
],
[
"DESCRIPTION",
"The compliance statement for UPSs that support advanced full-featured functions."
],
null,
[
"ComplianceModules",
[
[
null,
[
"ups28FullIdentGroup",
"ups28FullBatteryGroup",
"ups28FullInputGroup",
"ups28FullOutputGroup",
"ups28FullAlarmGroup",
"ups28FullTestGroup",
"ups28FullControlGroup"
]
]
]
]
]
}Vendor MIB copy from the LibreNMS archive.
Module: ABBMODULARUPS-MIB
ups28FullCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for UPSs that support
advanced full-featured functions."
MODULE -- this module
MANDATORY-GROUPS { ups28FullIdentGroup, ups28FullBatteryGroup,
ups28FullInputGroup, ups28FullOutputGroup,
ups28FullAlarmGroup, ups28FullTestGroup,
ups28FullControlGroup }
OBJECT ups28AlarmDescr
DESCRIPTION
"Support of all `well known' alarm types is not
required. The well known alarm types which must be
supported are: ups28AlarmBatteryBad, ups28AlarmOnBattery,
ups28AlarmLowBattery, ups28AlarmDepletedBattery,
ups28AlarmTempBad, ups28AlarmInputBad, ups28AlarmOnBypass,
ups28AlarmBypassBad, ups28AlarmOutputOffAsRequested,
ups28AlarmUpsOffAsRequested, ups28AlarmUpsOutputOff,
ups28AlarmUpsSystemOff, ups28AlarmGeneralFault,
ups28AlarmDiagnosticTestFailed,
ups28AlarmCommunicationsLost, ups28AlarmShutdownPending,
and ups28AlarmTestInProgress."
OBJECT ups28TestId
DESCRIPTION
"Support of all `well known' test types is not
required. The well known test types which must be
supported are: ups28TestNoTestsInitiated,
ups28TestGeneralSystemsTest, and
ups28TestQuickBatteryTest."
OBJECT ups28OutputSource
SYNTAX INTEGER {
normal(2),
battery(4)
}
DESCRIPTION
"Support of the values other(1), none(2), bypass(4),
booster(6) and reducer(7) is not required."
GROUP ups28FullBypassGroup
DESCRIPTION
"The ups28FullBypassGroup is only required for UPSs that
have a Bypass present."
OBJECT ups28ShutdownType
MIN-ACCESS read-only
DESCRIPTION
"Read-write access is not required, i.e., compliant
systems need not support more than one shutdown type."
::= { ups28Compliances 3 }{'SNMPv2-TC': ['DisplayString', 'TimeStamp', 'TimeInterval', 'TestAndIncr', 'AutonomousType', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'OBJECT-IDENTITY', 'Counter32', 'Gauge32', 'Integer32', 'Unsigned32', 'enterprises'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP']}Related source files and packages: