ups02BasicCompliance — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
The compliance statement for UPSs that support full-featured functions, such as control.
{1 3 6 1 4 1 53973 1 1 3 3 1 2}
The compliance statement for UPSs that support full-featured functions, such as control.
Status in source: current.
Names: ups02BasicCompliance
{
"smi_kind": "MODULE-COMPLIANCE",
"definition": [
"ups02BasicCompliance",
"MODULE-COMPLIANCE",
"STATUS",
"current",
"DESCRIPTION",
"\"The compliance statement for UPSs that support full-featured functions, such as control.\"",
"MODULE",
"MANDATORY-GROUPS",
"{",
"ups02BasicIdentGroup",
",",
"ups02BasicBatteryGroup",
",",
"ups02BasicInputGroup",
",",
"ups02BasicOutputGroup",
",",
"ups02BasicAlarmGroup",
",",
"ups02BasicTestGroup",
",",
"ups02BasicControlGroup",
"}",
"OBJECT",
"ups02AlarmDescr",
"DESCRIPTION",
"\"Support of all `well known' alarm types is not required. The well known alarm types which must be supported are: ups02AlarmOnBattery, ups02AlarmLowBattery, ups02AlarmDepletedBattery, ups02AlarmTempBad, ups02AlarmInputBad, ups02AlarmOutputOverload, ups02AlarmOnBypass, ups02AlarmBypassBad, ups02AlarmOutputOffAsRequested, ups02AlarmUpsOffAsRequested, ups02AlarmUpsOutputOff, ups02AlarmUpsSystemOff, ups02AlarmGeneralFault, ups02AlarmDiagnosticTestFailed, ups02AlarmCommunicationsLost, ups02AlarmShutdownPending, and ups02AlarmTestInProgress.\"",
"OBJECT",
"ups02TestId",
"DESCRIPTION",
"\"Support of all `well known' test types is not required. If no tests are supported, then the only well known test type which must be supported is ups02TestNoTestsInitiated.\"",
"OBJECT",
"ups02OutputSource",
"SYNTAX",
"INTEGER",
"{",
"normal",
"(",
"2",
")",
",",
"battery",
"(",
"4",
")",
"}",
"DESCRIPTION",
"\"Support of the values other(1), none(2), bypass(4), booster(6) and reducer(7) is not required.\"",
"GROUP",
"ups02BasicBypassGroup",
"DESCRIPTION",
"\"The ups02BasicBypassGroup is only required for UPSs that have a Bypass present.\"",
"OBJECT",
"ups02ShutdownType",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Read-write access is not required, i.e., compliant systems need not support more than one shutdown type.\"",
"::=",
"{",
"ups02Compliances",
"2",
"}"
],
"syntax_tree": [
[
"Status",
"current"
],
[
"DESCRIPTION",
"The compliance statement for UPSs that support full-featured functions, such as control."
],
null,
[
"ComplianceModules",
[
[
null,
[
"ups02BasicIdentGroup",
"ups02BasicBatteryGroup",
"ups02BasicInputGroup",
"ups02BasicOutputGroup",
"ups02BasicAlarmGroup",
"ups02BasicTestGroup",
"ups02BasicControlGroup"
]
]
]
]
]
}Vendor MIB copy from the LibreNMS archive.
Module: ABBMODULARUPS-MIB
ups02BasicCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for UPSs that support
full-featured functions, such as control."
MODULE -- this module
MANDATORY-GROUPS { ups02BasicIdentGroup,
ups02BasicBatteryGroup, ups02BasicInputGroup,
ups02BasicOutputGroup, ups02BasicAlarmGroup,
ups02BasicTestGroup, ups02BasicControlGroup }
OBJECT ups02AlarmDescr
DESCRIPTION
"Support of all `well known' alarm types is not
required. The well known alarm types which must be
supported are: ups02AlarmOnBattery, ups02AlarmLowBattery,
ups02AlarmDepletedBattery, ups02AlarmTempBad,
ups02AlarmInputBad, ups02AlarmOutputOverload,
ups02AlarmOnBypass, ups02AlarmBypassBad,
ups02AlarmOutputOffAsRequested,
ups02AlarmUpsOffAsRequested, ups02AlarmUpsOutputOff,
ups02AlarmUpsSystemOff, ups02AlarmGeneralFault,
ups02AlarmDiagnosticTestFailed,
ups02AlarmCommunicationsLost, ups02AlarmShutdownPending,
and ups02AlarmTestInProgress."
OBJECT ups02TestId
DESCRIPTION
"Support of all `well known' test types is not
required. If no tests are supported, then the only
well known test type which must be supported is
ups02TestNoTestsInitiated."
OBJECT ups02OutputSource
SYNTAX INTEGER {
normal(2),
battery(4)
}
DESCRIPTION
"Support of the values other(1), none(2), bypass(4),
booster(6) and reducer(7) is not required."
GROUP ups02BasicBypassGroup
DESCRIPTION
"The ups02BasicBypassGroup is only required for UPSs
that have a Bypass present."
OBJECT ups02ShutdownType
MIN-ACCESS read-only
DESCRIPTION
"Read-write access is not required, i.e., compliant
systems need not support more than one shutdown type."
::= { ups02Compliances 2 }{'SNMPv2-TC': ['DisplayString', 'TimeStamp', 'TimeInterval', 'TestAndIncr', 'AutonomousType', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'OBJECT-IDENTITY', 'Counter32', 'Gauge32', 'Integer32', 'Unsigned32', 'enterprises'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP']}Related source files and packages:
Downloaded: 2026-10-24T02:14:13.121331+00:00.
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.53973.1.1.3.3.1.1 | ups02SubsetCompliance | 0 | 0 | |
| 1.3.6.1.4.1.53973.1.1.3.3.1.3 | ups02FullCompliance | 0 | 0 |