ups04FullCompliance — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
The compliance statement for UPSs that support advanced full-featured functions.
{1 3 6 1 4 1 53973 1 1 5 3 1 3}
The compliance statement for UPSs that support advanced full-featured functions.
Status in source: current.
Names: ups04FullCompliance
{
"smi_kind": "MODULE-COMPLIANCE",
"definition": [
"ups04FullCompliance",
"MODULE-COMPLIANCE",
"STATUS",
"current",
"DESCRIPTION",
"\"The compliance statement for UPSs that support advanced full-featured functions.\"",
"MODULE",
"MANDATORY-GROUPS",
"{",
"ups04FullIdentGroup",
",",
"ups04FullBatteryGroup",
",",
"ups04FullInputGroup",
",",
"ups04FullOutputGroup",
",",
"ups04FullAlarmGroup",
",",
"ups04FullTestGroup",
",",
"ups04FullControlGroup",
"}",
"OBJECT",
"ups04AlarmDescr",
"DESCRIPTION",
"\"Support of all `well known' alarm types is not required. The well known alarm types which must be supported are: ups04AlarmBatteryBad, ups04AlarmOnBattery, ups04AlarmLowBattery, ups04AlarmDepletedBattery, ups04AlarmTempBad, ups04AlarmInputBad, ups04AlarmOnBypass, ups04AlarmBypassBad, ups04AlarmOutputOffAsRequested, ups04AlarmUpsOffAsRequested, ups04AlarmUpsOutputOff, ups04AlarmUpsSystemOff, ups04AlarmGeneralFault, ups04AlarmDiagnosticTestFailed, ups04AlarmCommunicationsLost, ups04AlarmShutdownPending, and ups04AlarmTestInProgress.\"",
"OBJECT",
"ups04TestId",
"DESCRIPTION",
"\"Support of all `well known' test types is not required. The well known test types which must be supported are: ups04TestNoTestsInitiated, ups04TestGeneralSystemsTest, and ups04TestQuickBatteryTest.\"",
"OBJECT",
"ups04OutputSource",
"SYNTAX",
"INTEGER",
"{",
"normal",
"(",
"2",
")",
",",
"battery",
"(",
"4",
")",
"}",
"DESCRIPTION",
"\"Support of the values other(1), none(2), bypass(4), booster(6) and reducer(7) is not required.\"",
"GROUP",
"ups04FullBypassGroup",
"DESCRIPTION",
"\"The ups04FullBypassGroup is only required for UPSs that have a Bypass present.\"",
"OBJECT",
"ups04ShutdownType",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Read-write access is not required, i.e., compliant systems need not support more than one shutdown type.\"",
"::=",
"{",
"ups04Compliances",
"3",
"}"
],
"syntax_tree": [
[
"Status",
"current"
],
[
"DESCRIPTION",
"The compliance statement for UPSs that support advanced full-featured functions."
],
null,
[
"ComplianceModules",
[
[
null,
[
"ups04FullIdentGroup",
"ups04FullBatteryGroup",
"ups04FullInputGroup",
"ups04FullOutputGroup",
"ups04FullAlarmGroup",
"ups04FullTestGroup",
"ups04FullControlGroup"
]
]
]
]
]
}Vendor MIB copy from the LibreNMS archive.
Module: ABBMODULARUPS-MIB
ups04FullCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for UPSs that support
advanced full-featured functions."
MODULE -- this module
MANDATORY-GROUPS { ups04FullIdentGroup, ups04FullBatteryGroup,
ups04FullInputGroup, ups04FullOutputGroup,
ups04FullAlarmGroup, ups04FullTestGroup,
ups04FullControlGroup }
OBJECT ups04AlarmDescr
DESCRIPTION
"Support of all `well known' alarm types is not
required. The well known alarm types which must be
supported are: ups04AlarmBatteryBad, ups04AlarmOnBattery,
ups04AlarmLowBattery, ups04AlarmDepletedBattery,
ups04AlarmTempBad, ups04AlarmInputBad, ups04AlarmOnBypass,
ups04AlarmBypassBad, ups04AlarmOutputOffAsRequested,
ups04AlarmUpsOffAsRequested, ups04AlarmUpsOutputOff,
ups04AlarmUpsSystemOff, ups04AlarmGeneralFault,
ups04AlarmDiagnosticTestFailed,
ups04AlarmCommunicationsLost, ups04AlarmShutdownPending,
and ups04AlarmTestInProgress."
OBJECT ups04TestId
DESCRIPTION
"Support of all `well known' test types is not
required. The well known test types which must be
supported are: ups04TestNoTestsInitiated,
ups04TestGeneralSystemsTest, and
ups04TestQuickBatteryTest."
OBJECT ups04OutputSource
SYNTAX INTEGER {
normal(2),
battery(4)
}
DESCRIPTION
"Support of the values other(1), none(2), bypass(4),
booster(6) and reducer(7) is not required."
GROUP ups04FullBypassGroup
DESCRIPTION
"The ups04FullBypassGroup is only required for UPSs that
have a Bypass present."
OBJECT ups04ShutdownType
MIN-ACCESS read-only
DESCRIPTION
"Read-write access is not required, i.e., compliant
systems need not support more than one shutdown type."
::= { ups04Compliances 3 }{'SNMPv2-TC': ['DisplayString', 'TimeStamp', 'TimeInterval', 'TestAndIncr', 'AutonomousType', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'OBJECT-IDENTITY', 'Counter32', 'Gauge32', 'Integer32', 'Unsigned32', 'enterprises'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP']}Related source files and packages: