ups08FullCompliance — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
The compliance statement for UPSs that support advanced full-featured functions.
{1 3 6 1 4 1 53973 1 1 9 3 1 3}
The compliance statement for UPSs that support advanced full-featured functions.
Status in source: current.
Names: ups08FullCompliance
{
"smi_kind": "MODULE-COMPLIANCE",
"definition": [
"ups08FullCompliance",
"MODULE-COMPLIANCE",
"STATUS",
"current",
"DESCRIPTION",
"\"The compliance statement for UPSs that support advanced full-featured functions.\"",
"MODULE",
"MANDATORY-GROUPS",
"{",
"ups08FullIdentGroup",
",",
"ups08FullBatteryGroup",
",",
"ups08FullInputGroup",
",",
"ups08FullOutputGroup",
",",
"ups08FullAlarmGroup",
",",
"ups08FullTestGroup",
",",
"ups08FullControlGroup",
"}",
"OBJECT",
"ups08AlarmDescr",
"DESCRIPTION",
"\"Support of all `well known' alarm types is not required. The well known alarm types which must be supported are: ups08AlarmBatteryBad, ups08AlarmOnBattery, ups08AlarmLowBattery, ups08AlarmDepletedBattery, ups08AlarmTempBad, ups08AlarmInputBad, ups08AlarmOnBypass, ups08AlarmBypassBad, ups08AlarmOutputOffAsRequested, ups08AlarmUpsOffAsRequested, ups08AlarmUpsOutputOff, ups08AlarmUpsSystemOff, ups08AlarmGeneralFault, ups08AlarmDiagnosticTestFailed, ups08AlarmCommunicationsLost, ups08AlarmShutdownPending, and ups08AlarmTestInProgress.\"",
"OBJECT",
"ups08TestId",
"DESCRIPTION",
"\"Support of all `well known' test types is not required. The well known test types which must be supported are: ups08TestNoTestsInitiated, ups08TestGeneralSystemsTest, and ups08TestQuickBatteryTest.\"",
"OBJECT",
"ups08OutputSource",
"SYNTAX",
"INTEGER",
"{",
"normal",
"(",
"2",
")",
",",
"battery",
"(",
"4",
")",
"}",
"DESCRIPTION",
"\"Support of the values other(1), none(2), bypass(4), booster(6) and reducer(7) is not required.\"",
"GROUP",
"ups08FullBypassGroup",
"DESCRIPTION",
"\"The ups08FullBypassGroup is only required for UPSs that have a Bypass present.\"",
"OBJECT",
"ups08ShutdownType",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Read-write access is not required, i.e., compliant systems need not support more than one shutdown type.\"",
"::=",
"{",
"ups08Compliances",
"3",
"}"
],
"syntax_tree": [
[
"Status",
"current"
],
[
"DESCRIPTION",
"The compliance statement for UPSs that support advanced full-featured functions."
],
null,
[
"ComplianceModules",
[
[
null,
[
"ups08FullIdentGroup",
"ups08FullBatteryGroup",
"ups08FullInputGroup",
"ups08FullOutputGroup",
"ups08FullAlarmGroup",
"ups08FullTestGroup",
"ups08FullControlGroup"
]
]
]
]
]
}Vendor MIB copy from the LibreNMS archive.
Module: ABBMODULARUPS-MIB
ups08FullCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for UPSs that support
advanced full-featured functions."
MODULE -- this module
MANDATORY-GROUPS { ups08FullIdentGroup, ups08FullBatteryGroup,
ups08FullInputGroup, ups08FullOutputGroup,
ups08FullAlarmGroup, ups08FullTestGroup,
ups08FullControlGroup }
OBJECT ups08AlarmDescr
DESCRIPTION
"Support of all `well known' alarm types is not
required. The well known alarm types which must be
supported are: ups08AlarmBatteryBad, ups08AlarmOnBattery,
ups08AlarmLowBattery, ups08AlarmDepletedBattery,
ups08AlarmTempBad, ups08AlarmInputBad, ups08AlarmOnBypass,
ups08AlarmBypassBad, ups08AlarmOutputOffAsRequested,
ups08AlarmUpsOffAsRequested, ups08AlarmUpsOutputOff,
ups08AlarmUpsSystemOff, ups08AlarmGeneralFault,
ups08AlarmDiagnosticTestFailed,
ups08AlarmCommunicationsLost, ups08AlarmShutdownPending,
and ups08AlarmTestInProgress."
OBJECT ups08TestId
DESCRIPTION
"Support of all `well known' test types is not
required. The well known test types which must be
supported are: ups08TestNoTestsInitiated,
ups08TestGeneralSystemsTest, and
ups08TestQuickBatteryTest."
OBJECT ups08OutputSource
SYNTAX INTEGER {
normal(2),
battery(4)
}
DESCRIPTION
"Support of the values other(1), none(2), bypass(4),
booster(6) and reducer(7) is not required."
GROUP ups08FullBypassGroup
DESCRIPTION
"The ups08FullBypassGroup is only required for UPSs that
have a Bypass present."
OBJECT ups08ShutdownType
MIN-ACCESS read-only
DESCRIPTION
"Read-write access is not required, i.e., compliant
systems need not support more than one shutdown type."
::= { ups08Compliances 3 }{'SNMPv2-TC': ['DisplayString', 'TimeStamp', 'TimeInterval', 'TestAndIncr', 'AutonomousType', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'OBJECT-IDENTITY', 'Counter32', 'Gauge32', 'Integer32', 'Unsigned32', 'enterprises'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP']}Related source files and packages: