Status in source: current.
Technical details
{
"smi_kind": "MODULE-COMPLIANCE",
"definition": [
"efmCuCompliance",
"MODULE-COMPLIANCE",
"STATUS",
"current",
"DESCRIPTION",
"\"The compliance statement for 2BASE-TL/10PASS-TS interfaces. Compliance with the following external compliance statements is prerequisite: MIB Module Compliance Statement ---------- -------------------- IF-MIB ifCompliance3 IF-INVERTED-STACK-MIB ifInvCompliance EtherLike-MIB dot3Compliance2 MAU-MIB mauModIfCompl3\"",
"MODULE",
"MANDATORY-GROUPS",
"{",
"efmCuBasicGroup",
",",
"efmCuPmeGroup",
",",
"efmCuAlarmConfGroup",
",",
"efmCuNotificationGroup",
"}",
"GROUP",
"efmCuPme2BProfileGroup",
"DESCRIPTION",
"\"Support for this group is only required for implementations supporting 2BASE-TL Phy.\"",
"GROUP",
"efmCuPme10PProfileGroup",
"DESCRIPTION",
"\"Support for this group is only required for implementations supporting 10PASS-TS Phy.\"",
"GROUP",
"efmCuPAFGroup",
"DESCRIPTION",
"\"Support for this group is only required for implementations supporting PME Aggregation Function (PAF).\"",
"GROUP",
"ifStackCapabilityGroup",
"DESCRIPTION",
"\"Support for this group is optional for implementations supporting layered interfaces architecture with flexible cross-connect between the layers.\"",
"GROUP",
"efmCuPAFErrorsGroup",
"DESCRIPTION",
"\"Support for this group is optional for implementations supporting PME Aggregation Function (PAF).\"",
"GROUP",
"efmCuPme10PStatusGroup",
"DESCRIPTION",
"\"Support for this group is optional for implementations supporting 10PASS-TS Phy.\"",
"OBJECT",
"efmCuPmeSubTypesSupported",
"SYNTAX",
"BITS",
"{",
"ieee2BaseTLO",
"(",
"0",
")",
",",
"ieee2BaseTLR",
"(",
"1",
")",
",",
"ieee10PassTSO",
"(",
"2",
")",
",",
"ieee10PassTSR",
"(",
"3",
")",
"}",
"DESCRIPTION",
"\"Support for all subtypes is not required. However at least one value SHALL be supported\"",
"OBJECT",
"efmCuPmeAdminSubType",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required (needed only for PMEs supporting more than a single subtype, e.g. ieee2BaseTLO and ieee2BaseTSR or ieee2BaseTLR and ieee10PassTSR)\"",
"OBJECT",
"efmCuTargetWorstCaseSnrMgn",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is optional. For PHYs without write access the target SNR margin SHALL be fixed at 5dB for 2BASE-TL and 6dB for 10PASS-TS.\"",
"OBJECT",
"efmCuTargetCurrentConditionSnrMgn",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is optional. For PHYs without write access the target SNR margin SHALL be fixed at 5dB for 2BASE-TL and 6dB for 10PASS-TS.\"",
"::=",
"{",
"efmCuCompliances",
"1",
"}"
],
"syntax_tree": [
[
"Status",
"current"
],
[
"DESCRIPTION",
"The compliance statement for 2BASE-TL/10PASS-TS interfaces. Compliance with the following external compliance statements is prerequisite: MIB Module Compliance Statement ---------- -------------------- IF-MIB ifCompliance3 IF-INVERTED-STACK-MIB ifInvCompliance EtherLike-MIB dot3Compliance2 MAU-MIB mauModIfCompl3"
],
null,
[
"ComplianceModules",
[
[
null,
[
"efmCuBasicGroup",
"efmCuPmeGroup",
"efmCuAlarmConfGroup",
"efmCuNotificationGroup",
"efmCuPme2BProfileGroup",
"efmCuPme10PProfileGroup",
"efmCuPAFGroup",
"ifStackCapabilityGroup",
"efmCuPAFErrorsGroup",
"efmCuPme10PStatusGroup"
]
]
]
]
]
}