Status in source: current.
Names: sechtor100ThermoATemperature
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"sechtor100ThermoATemperature",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"(",
"-",
"55",
".",
".",
"125",
")",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"The temperature in degrees Celsius read by the IC thermometer sensor A on the PCB board. It is effectively the internal ambient temperature inside the enclosure where thermometer A is located. The valid temperature range for the thermometer is -55..125 degrees Celsius.\"",
"::=",
"{",
"sechtor100ConfigEntry",
"8",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32",
[
"integerSubType",
[
[
-55,
125
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The temperature in degrees Celsius read by the IC thermometer sensor A on the PCB board. It is effectively the internal ambient temperature inside the enclosure where thermometer A is located. The valid temperature range for the thermometer is -55..125 degrees Celsius."
],
null,
null,
null,
null
]
}
- Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
· Publisher's source file: Source package: observium-community-latest.tar.gz
Vendor MIB copy from the Observium Community archive.
Module: ZHONE-SECHTOR100-MIB
See published definition above
Module imports
{'Zhone': ['sechtor100', 'zhoneModules', 'zhoneShelfIndex', 'zhoneSlotIndex'], 'Zhone-TC': ['ZhoneRowStatus'], 'SNMPv2-TC': ['MacAddress', 'TruthValue'], 'SNMPv2-SMI': ['Integer32', 'OBJECT-TYPE', 'MODULE-IDENTITY', 'OBJECT-IDENTITY', 'NOTIFICATION-TYPE']}
· Download ZHONE-SECHTOR100-MIB
Related source files and packages: