Trap sent by a CPE when the upload of a configuration file initiated by CPE Config Manager fails.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.5504.3.1.21.1.3.0.7
Trap sent by a CPE when the upload of a configuration file initiated by CPE Config Manager fails.
Identification
{1 3 6 1 4 1 5504 3 1 21 1 3 0 7}
The displayed source records contain one distinct definition. Compare its source records.
cpeCfgMgrClientConfigBackupFailed NOTIFICATION-TYPE
OBJECTS { cpeCfgMgrClientSerialNumber, cpeCfgMgrClientRegistrationID, cpeCfgMgrClientState, cpeCfgMgrClientErrorDescription, cpeCfgMgrClientRequiredUpdates,
cpeCfgMgrClientReceivedSpecificCfgFilename, cpeCfgMgrClientDwnldSrvrBasePath, cpeCfgMgrClientDwnldSpecificPath, cpeCfgMgrClientDwnldSrvrIP, cpeCfgMgrClientDwnldSrvrUsername,
cpeCfgMgrClientDwnldSrvrSecureMode }
STATUS current
DESCRIPTION
"Trap sent by a CPE when the upload of a configuration file
initiated by CPE Config Manager fails."
::= { cpeCfgMgrClientNotifications 7 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Trap sent by a CPE when the upload of a configuration file initiated by CPE Config Manager fails.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: cpeCfgMgrClientConfigBackupFailed
{
"smi_kind": "NOTIFICATION-TYPE",
"definition": [
"cpeCfgMgrClientConfigBackupFailed",
"NOTIFICATION-TYPE",
"OBJECTS",
"{",
"cpeCfgMgrClientSerialNumber",
",",
"cpeCfgMgrClientRegistrationID",
",",
"cpeCfgMgrClientState",
",",
"cpeCfgMgrClientErrorDescription",
",",
"cpeCfgMgrClientRequiredUpdates",
",",
"cpeCfgMgrClientReceivedSpecificCfgFilename",
",",
"cpeCfgMgrClientDwnldSrvrBasePath",
",",
"cpeCfgMgrClientDwnldSpecificPath",
",",
"cpeCfgMgrClientDwnldSrvrIP",
",",
"cpeCfgMgrClientDwnldSrvrUsername",
",",
"cpeCfgMgrClientDwnldSrvrSecureMode",
"}",
"STATUS",
"current",
"DESCRIPTION",
"\"Trap sent by a CPE when the upload of a configuration file initiated by CPE Config Manager fails.\"",
"::=",
"{",
"cpeCfgMgrClientNotifications",
"7",
"}"
],
"syntax_tree": [
[
"Objects",
[
"cpeCfgMgrClientSerialNumber",
"cpeCfgMgrClientRegistrationID",
"cpeCfgMgrClientState",
"cpeCfgMgrClientErrorDescription",
"cpeCfgMgrClientRequiredUpdates",
"cpeCfgMgrClientReceivedSpecificCfgFilename",
"cpeCfgMgrClientDwnldSrvrBasePath",
"cpeCfgMgrClientDwnldSpecificPath",
"cpeCfgMgrClientDwnldSrvrIP",
"cpeCfgMgrClientDwnldSrvrUsername",
"cpeCfgMgrClientDwnldSrvrSecureMode"
]
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Trap sent by a CPE when the upload of a configuration file initiated by CPE Config Manager fails."
],
null
]
}Vendor MIB copy from the Observium Community archive.
Module: CPE-MANAGER
See published definition above
{'IF-MIB': ['ifIndex'], 'Zhone-TC': ['ZhoneRowStatus'], 'SNMPv2-TC': ['TruthValue', 'MacAddress'], 'SNMPv2-SMI': ['IpAddress', 'Integer32', 'Unsigned32', 'OBJECT-TYPE', 'MODULE-IDENTITY', 'OBJECT-IDENTITY', 'NOTIFICATION-TYPE'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE', 'NOTIFICATION-GROUP'], 'ZHONE-SYSTEM-MIB': ['cpeMgr']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.5504.3.1.21.1.3.0.1 | cpeCfgMgrClientSoftwareDownloadFailed | 0 | 0 | |
| 1.3.6.1.4.1.5504.3.1.21.1.3.0.2 | cpeCfgMgrClientSoftwareInstallFailed | 0 | 0 | |
| 1.3.6.1.4.1.5504.3.1.21.1.3.0.3 | cpeCfgMgrClientWebUIDownloadFailed | 0 | 0 | |
| 1.3.6.1.4.1.5504.3.1.21.1.3.0.4 | cpeCfgMgrClientWebUIInstallFailed | 0 | 0 | |
| 1.3.6.1.4.1.5504.3.1.21.1.3.0.5 | cpeCfgMgrClientConfigDownloadFailed | 0 | 0 | |
| 1.3.6.1.4.1.5504.3.1.21.1.3.0.6 | cpeCfgMgrClientConfigUpdateFailed | 0 | 0 | |
| 1.3.6.1.4.1.5504.3.1.21.1.3.0.8 | cpeCfgMgrClientLevelReady | 0 | 0 | |
| 1.3.6.1.4.1.5504.3.1.21.1.3.0.9 | cpeCfgMgrClientConfigBackupDone | 0 | 0 |