Status in source: current.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"zhoneUserAccessLevel",
"OBJECT-TYPE",
"SYNTAX",
"BITS",
"{",
"userAccessAdmin",
"(",
"0",
")",
",",
"userAccessVoice",
"(",
"1",
")",
",",
"userAccessData",
"(",
"2",
")",
",",
"userAccessManuf",
"(",
"3",
")",
",",
"userAccessDatabase",
"(",
"4",
")",
",",
"userAccessSystems",
"(",
"5",
")",
",",
"userAccessTool",
"(",
"6",
")",
",",
"userAccessDebug",
"(",
"7",
")",
"}",
"MAX-ACCESS",
"read-create",
"STATUS",
"current",
"DESCRIPTION",
"\"Array of access levels that a user may have. This is an OR field where a user may have access to different subsystems. Only exception is Admin access level which allows access to all functions in the system. userAccessAdmin - allows access to all entities of the system. userAccessVoice - allows access to voice specific configuration and information. userAccessData - allows access to the data (i.e. IP) configuration and information. userAccessManuf - allows access to the manufacturing components of the system. userAccessDatabase - allows access to the database allowing write access. For any access except admin, this value must be set to allow any changes to be saved by this user. userAccessSystems - allows access to the system information. userAccessTool - allows access to system tools which help administer the system. userAccessDebug - allows access to Zhone Debug commands. This access should rarely be specified. There is No default value and a value must be specified for the user entry to be created. \"",
"::=",
"{",
"zhoneUserEntry",
"5",
"}"
],
"syntax_tree": [
[
"BITS",
[
[
"userAccessAdmin",
0
],
[
"userAccessVoice",
1
],
[
"userAccessData",
2
],
[
"userAccessManuf",
3
],
[
"userAccessDatabase",
4
],
[
"userAccessSystems",
5
],
[
"userAccessTool",
6
],
[
"userAccessDebug",
7
]
]
],
null,
[
"MaxAccessPart",
"read-create"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Array of access levels that a user may have. This is an OR field where a user may have access to different subsystems. Only exception is Admin access level which allows access to all functions in the system. userAccessAdmin - allows access to all entities of the system. userAccessVoice - allows access to voice specific configuration and information. userAccessData - allows access to the data (i.e. IP) configuration and information. userAccessManuf - allows access to the manufacturing components of the system. userAccessDatabase - allows access to the database allowing write access. For any access except admin, this value must be set to allow any changes to be saved by this user. userAccessSystems - allows access to the system information. userAccessTool - allows access to system tools which help administer the system. userAccessDebug - allows access to Zhone Debug commands. This access should rarely be specified. There is No default value and a value must be specified for the user entry to be created."
],
null,
null,
null,
null
]
}