Status in source: current.
Names: zhoneSystemOutletTemperatureHighThreshold
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"zhoneSystemOutletTemperatureHighThreshold",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"(",
"35",
".",
".",
"75",
")",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"Specifies the outlet sensor high temperature threshold. Minor, Major & Critical alarms will be raised when outlet sensor temperature reaches X, X+5 & X+10 respectively. X is the value of this field. Allowed range for MXK & MX1U products is 35 to 65 Allowed range for MX1U160Lt is 35 to 75\"",
"DEFVAL",
"{",
"65",
"}",
"::=",
"{",
"zhoneSystemConfiguration",
"26",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32",
[
"integerSubType",
[
[
35,
75
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Specifies the outlet sensor high temperature threshold. Minor, Major & Critical alarms will be raised when outlet sensor temperature reaches X, X+5 & X+10 respectively. X is the value of this field. Allowed range for MXK & MX1U products is 35 to 65 Allowed range for MX1U160Lt is 35 to 75"
],
null,
null,
null,
[
"DEFVAL",
65
]
]
}