OID reference

zhoneTacTestId

1.3.6.1.4.1.5504.3.3.7.1.4

Description

This object is only valid for Tac Cards which support the new Legerity Suite of tests. This object identifies which test is to be run, or can be set to abort the current test. Test results are sent to the zhoneTacTestResultsTable. There are 3 Legerity software packages: Basic Test (VCP-BT), Advanced Test (VCP-AT), and…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.5504.3.3.7.1 (zhoneTacTestEntry)
Node code
4
Node name
zhoneTacTestId
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.5504.3.3.7.1.4
URN notation
urn:oid:1.3.6.1.4.1.5504.3.3.7.1.4
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 5504 3 3 7 1 4}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) zhone(5504) zhoneGeneric(3) zhoneCard(3) zhoneTacTestTable(7) zhoneTacTestEntry(1) zhoneTacTestId(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) zhone(5504) zhoneGeneric(3) zhoneCard(3) zhoneTacTestTable(7) zhoneTacTestEntry(1) zhoneTacTestId(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) zhone(5504) zhoneGeneric(3) zhoneCard(3) zhoneTacTestTable(7) zhoneTacTestEntry(1) zhoneTacTestId(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) zhone(5504) zhoneGeneric(3) zhoneCard(3) zhoneTacTestTable(7) zhoneTacTestEntry(1) zhoneTacTestId(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) zhone(5504) zhoneGeneric(3) zhoneCard(3) zhoneTacTestTable(7) zhoneTacTestEntry(1) zhoneTacTestId(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) zhone(5504) zhoneGeneric(3) zhoneCard(3) zhoneTacTestTable(7) zhoneTacTestEntry(1) zhoneTacTestId(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) zhone(5504) zhoneGeneric(3) zhoneCard(3) zhoneTacTestTable(7) zhoneTacTestEntry(1) zhoneTacTestId(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) zhone(5504) zhoneGeneric(3) zhoneCard(3) zhoneTacTestTable(7) zhoneTacTestEntry(1) zhoneTacTestId(4)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) zhone(5504) zhoneGeneric(3) zhoneCard(3) zhoneTacTestTable(7) zhoneTacTestEntry(1) zhoneTacTestId(4)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) zhone(5504) zhoneGeneric(3) zhoneCard(3) zhoneTacTestTable(7) zhoneTacTestEntry(1) zhoneTacTestId(4)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) zhone(5504) zhoneGeneric(3) zhoneCard(3) zhoneTacTestTable(7) zhoneTacTestEntry(1) zhoneTacTestId(4)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) zhone(5504) zhoneGeneric(3) zhoneCard(3) zhoneTacTestTable(7) zhoneTacTestEntry(1) zhoneTacTestId(4)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) zhone(5504) zhoneGeneric(3) zhoneCard(3) zhoneTacTestTable(7) zhoneTacTestEntry(1) zhoneTacTestId(4)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) zhone(5504) zhoneGeneric(3) zhoneCard(3) zhoneTacTestTable(7) zhoneTacTestEntry(1) zhoneTacTestId(4)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) zhone(5504) zhoneGeneric(3) zhoneCard(3) zhoneTacTestTable(7) zhoneTacTestEntry(1) zhoneTacTestId(4)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) zhone(5504) zhoneGeneric(3) zhoneCard(3) zhoneTacTestTable(7) zhoneTacTestEntry(1) zhoneTacTestId(4)}
OID-IRI notation
  • /1/3/6/1/4/1/5504/3/3/7/1/4
  • /ISO/Identified-Organization/6/1/4/1/5504/3/3/7/1/4
  • /ISO/3/6/1/4/1/5504/3/3/7/1/4
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/5504/zhoneGeneric/zhoneCard/zhoneTacTestTable/zhoneTacTestEntry/zhoneTacTestId
  • /iso/identified-organization/dod/internet/private/enterprise/zhone/zhoneGeneric/zhoneCard/zhoneTacTestTable/zhoneTacTestEntry/zhoneTacTestId
  • /iso/identified-organization/dod/internet/private/enterprise/Zhone/zhoneGeneric/zhoneCard/zhoneTacTestTable/zhoneTacTestEntry/zhoneTacTestId
  • /iso/identified-organization/dod/internet/private/enterprises/5504/zhoneGeneric/zhoneCard/zhoneTacTestTable/zhoneTacTestEntry/zhoneTacTestId
  • /iso/identified-organization/dod/internet/private/enterprises/zhone/zhoneGeneric/zhoneCard/zhoneTacTestTable/zhoneTacTestEntry/zhoneTacTestId
  • /iso/identified-organization/dod/internet/private/enterprises/Zhone/zhoneGeneric/zhoneCard/zhoneTacTestTable/zhoneTacTestEntry/zhoneTacTestId
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/5504/zhoneGeneric/zhoneCard/zhoneTacTestTable/zhoneTacTestEntry/zhoneTacTestId
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/zhone/zhoneGeneric/zhoneCard/zhoneTacTestTable/zhoneTacTestEntry/zhoneTacTestId
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/Zhone/zhoneGeneric/zhoneCard/zhoneTacTestTable/zhoneTacTestEntry/zhoneTacTestId
  • /iso/identified-organization/dod/internet/private/vendor-objects/5504/zhoneGeneric/zhoneCard/zhoneTacTestTable/zhoneTacTestEntry/zhoneTacTestId
  • /iso/identified-organization/dod/internet/private/vendor-objects/zhone/zhoneGeneric/zhoneCard/zhoneTacTestTable/zhoneTacTestEntry/zhoneTacTestId
  • /iso/identified-organization/dod/internet/private/vendor-objects/Zhone/zhoneGeneric/zhoneCard/zhoneTacTestTable/zhoneTacTestEntry/zhoneTacTestId
  • /iso/org/dod/internet/private/enterprise/5504/zhoneGeneric/zhoneCard/zhoneTacTestTable/zhoneTacTestEntry/zhoneTacTestId
  • /iso/org/dod/internet/private/enterprise/zhone/zhoneGeneric/zhoneCard/zhoneTacTestTable/zhoneTacTestEntry/zhoneTacTestId
  • /iso/org/dod/internet/private/enterprise/Zhone/zhoneGeneric/zhoneCard/zhoneTacTestTable/zhoneTacTestEntry/zhoneTacTestId
  • /iso/org/dod/internet/private/enterprises/5504/zhoneGeneric/zhoneCard/zhoneTacTestTable/zhoneTacTestEntry/zhoneTacTestId
  • Additional combinations skipped.

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
current
Default value
none

Enumerated values

ValueName
1none
2runAllTests
3abortTest
4calibration
5foreignDCVoltage
6foreignACVoltage
7dcLoopResistance
8threeElementInsulationResistance
9fiveElementInsulationResistance
10threeElementCapacitance
11receiverOffHook
12distanceToOpen
13foreignACCurrents
14ringerEquivalencyNumber
15dtmfAndPulseDigitMeasurement
16noiseMeasurement
17signalToNoiseRatio
18arbitrarySignalToneMeasurement
19toneGeneration
20transHybridLoss
21drawAndBreakDialTone
22inwardCurrent
23dcFeedSelf
24onAndOffHookSelfTest
25ringingSelfTest
26ringingMonitor
27meteringSelfTest
28transmissionSelfTest
29dialingSelfTest
30howlerTest
31fuseTest
32readLoopAndBatteryConditions

Using this OID with SNMP

At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.

In ZHONE-CARD-DIAGNOSTICS-MIB, the row index zhoneTacIndex is declared as Integer32. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.5504.3.3.7.1.4.<zhoneTacIndex>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.

Published row index: zhoneTacIndex.

snmpwalk [connection options] DEVICE .1.3.6.1.4.1.5504.3.3.7.1.4

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

The displayed source records contain one distinct definition. Compare its source records.

zhoneTacTestId OBJECT-TYPE
			SYNTAX INTEGER
				{
				none(1),
				runAllTests(2),
				abortTest(3),
				calibration(4),
				foreignDCVoltage(5),
				foreignACVoltage(6),
				dcLoopResistance(7),
				threeElementInsulationResistance(8),
				fiveElementInsulationResistance(9),
				threeElementCapacitance(10),
				receiverOffHook(11),
				distanceToOpen(12),
				foreignACCurrents(13),
				ringerEquivalencyNumber(14),
				dtmfAndPulseDigitMeasurement(15),
				noiseMeasurement(16),
				signalToNoiseRatio(17),
				arbitrarySignalToneMeasurement(18),
				toneGeneration(19),
				transHybridLoss(20),
				drawAndBreakDialTone(21),
				inwardCurrent(22),
				dcFeedSelf(23),
				onAndOffHookSelfTest(24),
				ringingSelfTest(25),
				ringingMonitor(26),
				meteringSelfTest(27),
				transmissionSelfTest(28),
				dialingSelfTest(29),
				howlerTest(30),
				fuseTest(31),
				readLoopAndBatteryConditions(32)
				}
			MAX-ACCESS read-write
			STATUS current
			DESCRIPTION
				"This object is only valid for Tac Cards which
				support the new Legerity Suite of tests.
				
				This object identifies which test is to
				be run, or can be set to abort the current test.
				
				Test results are sent to the zhoneTacTestResultsTable.
				
				There are 3 Legerity software packages: Basic Test (VCP-BT),
				Advanced Test (VCP-AT), and Advanced Test Plus (VCP-ATP).
				We currently support Basic Test package.
				The following lists which tests are supported in each 
				software package.
				
				Calibration	VCP-ATP
				Foreign DC Voltage Test	VCP-BT, VCP-AT, VCP-ATP
				Foreign AC VoltageTest	VCP-BT, VCP-AT, VCP-ATP
				DC Loop Resistance Test	VCP-BT, VCP-AT, VCP-ATP
				Three-Element Insulation Resistance Test	VCP-BT, VCP-AT, VCP-ATP
				Five-Element Insulation Resistance Test	VCP-ATP
				Three-Element Capacitance Test	VCP-BT, VCP-AT
				Receiver Off-Hook Test	VCP-BT, VCP-AT, VCP-ATP
				Distance to Open Test 	VCP-BT, VCP-AT
				Foreign AC Currents Test	VCP-BT, VCP-AT
				Ringer Equivalency Number Test	VCP-BT, VCP-AT, VCP-ATP
				DTMF and Pulse Digit Measurement Test	VCP-BT, VCP-AT
				Noise Measurement Test	VCP-BT, VCP-AT, VCP-ATP
				Signal to Noise Ratio Test	VCP-ATP
				Arbitrary Single Tone Measurement Test	VCP-ATP
				Tone Generation Test	VCP-BT, VCP-AT
				Trans-Hybrid Loss Test	VCP-BT, VCP-AT, VCP-ATP
				Draw and Break Dial Tone Test	VCP-BT, VCP-AT
				Inward Current Test 	VCP-ATP
				DC Feed Self-Test	VCP-BT, VCP-AT, VCP-ATP
				On/Off Hook Self-Test	VCP-BT, VCP-AT, VCP-ATP
				Ringing Self-Test 	VCP-BT, VCP-AT, VCP-ATP
				Ringing Monitor Test	VCP-BT, VCP-AT, VCP-ATP
				Metering Self-Test	VCP-BT, VCP-AT
				Transmission Self-Test	VCP-BT, VCP-AT, VCP-ATP
				Dialing Sef Test	VCP-BT, VCP-AT
				Howler Test	VCP-BT, VCP-AT
				Fuse Test	VCP-ATP
				Read Loop and Battery Conditions	VCP-BT, VCP-AT, VCP-ATP
				"
			DEFVAL { none }
			::= { zhoneTacTestEntry 4 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

This object is only valid for Tac Cards which support the new Legerity Suite of tests. This object identifies which test is to be run, or can be set to abort the current test. Test results are sent to the zhoneTacTestResultsTable. There are 3 Legerity software packages: Basic Test (VCP-BT), Advanced Test (VCP-AT), and Advanced Test Plus (VCP-ATP). We currently support Basic Test package. The following lists which tests are supported in each software package. Calibration VCP-ATP Foreign DC Voltage Test VCP-BT, VCP-AT, VCP-ATP Foreign AC VoltageTest VCP-BT, VCP-AT, VCP-ATP DC Loop Resistance Test VCP-BT, VCP-AT, VCP-ATP Three-Element Insulation Resistance Test VCP-BT, VCP-AT, VCP-ATP Five-Element Insulation Resistance Test VCP-ATP Three-Element Capacitance Test VCP-BT, VCP-AT Receiver Off-Hook Test VCP-BT, VCP-AT, VCP-ATP Distance to Open Test VCP-BT, VCP-AT Foreign AC Currents Test VCP-BT, VCP-AT Ringer Equivalency Number Test VCP-BT, VCP-AT, VCP-ATP DTMF and Pulse Digit Measurement Test VCP-BT, VCP-AT Noise Measurement Test VCP-BT, VCP-AT, VCP-ATP Signal to Noise Ratio Test VCP-ATP Arbitrary Single Tone Measurement Test VCP-ATP Tone Generation Test VCP-BT, VCP-AT Trans-Hybrid Loss Test VCP-BT, VCP-AT, VCP-ATP Draw and Break Dial Tone Test VCP-BT, VCP-AT Inward Current Test VCP-ATP DC Feed Self-Test VCP-BT, VCP-AT, VCP-ATP On/Off Hook Self-Test VCP-BT, VCP-AT, VCP-ATP Ringing Self-Test VCP-BT, VCP-AT, VCP-ATP Ringing Monitor Test VCP-BT, VCP-AT, VCP-ATP Metering Self-Test VCP-BT, VCP-AT Transmission Self-Test VCP-BT, VCP-AT, VCP-ATP Dialing Sef Test VCP-BT, VCP-AT Howler Test VCP-BT, VCP-AT Fuse Test VCP-ATP Read Loop and Battery Conditions VCP-BT, VCP-AT, VCP-ATP

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 1

zhoneTacTestId · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: zhoneTacTestId

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "zhoneTacTestId",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "none",
    "(",
    "1",
    ")",
    ",",
    "runAllTests",
    "(",
    "2",
    ")",
    ",",
    "abortTest",
    "(",
    "3",
    ")",
    ",",
    "calibration",
    "(",
    "4",
    ")",
    ",",
    "foreignDCVoltage",
    "(",
    "5",
    ")",
    ",",
    "foreignACVoltage",
    "(",
    "6",
    ")",
    ",",
    "dcLoopResistance",
    "(",
    "7",
    ")",
    ",",
    "threeElementInsulationResistance",
    "(",
    "8",
    ")",
    ",",
    "fiveElementInsulationResistance",
    "(",
    "9",
    ")",
    ",",
    "threeElementCapacitance",
    "(",
    "10",
    ")",
    ",",
    "receiverOffHook",
    "(",
    "11",
    ")",
    ",",
    "distanceToOpen",
    "(",
    "12",
    ")",
    ",",
    "foreignACCurrents",
    "(",
    "13",
    ")",
    ",",
    "ringerEquivalencyNumber",
    "(",
    "14",
    ")",
    ",",
    "dtmfAndPulseDigitMeasurement",
    "(",
    "15",
    ")",
    ",",
    "noiseMeasurement",
    "(",
    "16",
    ")",
    ",",
    "signalToNoiseRatio",
    "(",
    "17",
    ")",
    ",",
    "arbitrarySignalToneMeasurement",
    "(",
    "18",
    ")",
    ",",
    "toneGeneration",
    "(",
    "19",
    ")",
    ",",
    "transHybridLoss",
    "(",
    "20",
    ")",
    ",",
    "drawAndBreakDialTone",
    "(",
    "21",
    ")",
    ",",
    "inwardCurrent",
    "(",
    "22",
    ")",
    ",",
    "dcFeedSelf",
    "(",
    "23",
    ")",
    ",",
    "onAndOffHookSelfTest",
    "(",
    "24",
    ")",
    ",",
    "ringingSelfTest",
    "(",
    "25",
    ")",
    ",",
    "ringingMonitor",
    "(",
    "26",
    ")",
    ",",
    "meteringSelfTest",
    "(",
    "27",
    ")",
    ",",
    "transmissionSelfTest",
    "(",
    "28",
    ")",
    ",",
    "dialingSelfTest",
    "(",
    "29",
    ")",
    ",",
    "howlerTest",
    "(",
    "30",
    ")",
    ",",
    "fuseTest",
    "(",
    "31",
    ")",
    ",",
    "readLoopAndBatteryConditions",
    "(",
    "32",
    ")",
    "}",
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"This object is only valid for Tac Cards which support the new Legerity Suite of tests. This object identifies which test is to be run, or can be set to abort the current test. Test results are sent to the zhoneTacTestResultsTable. There are 3 Legerity software packages: Basic Test (VCP-BT), Advanced Test (VCP-AT), and Advanced Test Plus (VCP-ATP). We currently support Basic Test package. The following lists which tests are supported in each software package. Calibration VCP-ATP Foreign DC Voltage Test VCP-BT, VCP-AT, VCP-ATP Foreign AC VoltageTest VCP-BT, VCP-AT, VCP-ATP DC Loop Resistance Test VCP-BT, VCP-AT, VCP-ATP Three-Element Insulation Resistance Test VCP-BT, VCP-AT, VCP-ATP Five-Element Insulation Resistance Test VCP-ATP Three-Element Capacitance Test VCP-BT, VCP-AT Receiver Off-Hook Test VCP-BT, VCP-AT, VCP-ATP Distance to Open Test VCP-BT, VCP-AT Foreign AC Currents Test VCP-BT, VCP-AT Ringer Equivalency Number Test VCP-BT, VCP-AT, VCP-ATP DTMF and Pulse Digit Measurement Test VCP-BT, VCP-AT Noise Measurement Test VCP-BT, VCP-AT, VCP-ATP Signal to Noise Ratio Test VCP-ATP Arbitrary Single Tone Measurement Test VCP-ATP Tone Generation Test VCP-BT, VCP-AT Trans-Hybrid Loss Test VCP-BT, VCP-AT, VCP-ATP Draw and Break Dial Tone Test VCP-BT, VCP-AT Inward Current Test VCP-ATP DC Feed Self-Test VCP-BT, VCP-AT, VCP-ATP On/Off Hook Self-Test VCP-BT, VCP-AT, VCP-ATP Ringing Self-Test VCP-BT, VCP-AT, VCP-ATP Ringing Monitor Test VCP-BT, VCP-AT, VCP-ATP Metering Self-Test VCP-BT, VCP-AT Transmission Self-Test VCP-BT, VCP-AT, VCP-ATP Dialing Sef Test VCP-BT, VCP-AT Howler Test VCP-BT, VCP-AT Fuse Test VCP-ATP Read Loop and Battery Conditions VCP-BT, VCP-AT, VCP-ATP \"",
    "DEFVAL",
    "{",
    "none",
    "}",
    "::=",
    "{",
    "zhoneTacTestEntry",
    "4",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "none",
            1
          ],
          [
            "runAllTests",
            2
          ],
          [
            "abortTest",
            3
          ],
          [
            "calibration",
            4
          ],
          [
            "foreignDCVoltage",
            5
          ],
          [
            "foreignACVoltage",
            6
          ],
          [
            "dcLoopResistance",
            7
          ],
          [
            "threeElementInsulationResistance",
            8
          ],
          [
            "fiveElementInsulationResistance",
            9
          ],
          [
            "threeElementCapacitance",
            10
          ],
          [
            "receiverOffHook",
            11
          ],
          [
            "distanceToOpen",
            12
          ],
          [
            "foreignACCurrents",
            13
          ],
          [
            "ringerEquivalencyNumber",
            14
          ],
          [
            "dtmfAndPulseDigitMeasurement",
            15
          ],
          [
            "noiseMeasurement",
            16
          ],
          [
            "signalToNoiseRatio",
            17
          ],
          [
            "arbitrarySignalToneMeasurement",
            18
          ],
          [
            "toneGeneration",
            19
          ],
          [
            "transHybridLoss",
            20
          ],
          [
            "drawAndBreakDialTone",
            21
          ],
          [
            "inwardCurrent",
            22
          ],
          [
            "dcFeedSelf",
            23
          ],
          [
            "onAndOffHookSelfTest",
            24
          ],
          [
            "ringingSelfTest",
            25
          ],
          [
            "ringingMonitor",
            26
          ],
          [
            "meteringSelfTest",
            27
          ],
          [
            "transmissionSelfTest",
            28
          ],
          [
            "dialingSelfTest",
            29
          ],
          [
            "howlerTest",
            30
          ],
          [
            "fuseTest",
            31
          ],
          [
            "readLoopAndBatteryConditions",
            32
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "This object is only valid for Tac Cards which support the new Legerity Suite of tests. This object identifies which test is to be run, or can be set to abort the current test. Test results are sent to the zhoneTacTestResultsTable. There are 3 Legerity software packages: Basic Test (VCP-BT), Advanced Test (VCP-AT), and Advanced Test Plus (VCP-ATP). We currently support Basic Test package. The following lists which tests are supported in each software package. Calibration VCP-ATP Foreign DC Voltage Test VCP-BT, VCP-AT, VCP-ATP Foreign AC VoltageTest VCP-BT, VCP-AT, VCP-ATP DC Loop Resistance Test VCP-BT, VCP-AT, VCP-ATP Three-Element Insulation Resistance Test VCP-BT, VCP-AT, VCP-ATP Five-Element Insulation Resistance Test VCP-ATP Three-Element Capacitance Test VCP-BT, VCP-AT Receiver Off-Hook Test VCP-BT, VCP-AT, VCP-ATP Distance to Open Test VCP-BT, VCP-AT Foreign AC Currents Test VCP-BT, VCP-AT Ringer Equivalency Number Test VCP-BT, VCP-AT, VCP-ATP DTMF and Pulse Digit Measurement Test VCP-BT, VCP-AT Noise Measurement Test VCP-BT, VCP-AT, VCP-ATP Signal to Noise Ratio Test VCP-ATP Arbitrary Single Tone Measurement Test VCP-ATP Tone Generation Test VCP-BT, VCP-AT Trans-Hybrid Loss Test VCP-BT, VCP-AT, VCP-ATP Draw and Break Dial Tone Test VCP-BT, VCP-AT Inward Current Test VCP-ATP DC Feed Self-Test VCP-BT, VCP-AT, VCP-ATP On/Off Hook Self-Test VCP-BT, VCP-AT, VCP-ATP Ringing Self-Test VCP-BT, VCP-AT, VCP-ATP Ringing Monitor Test VCP-BT, VCP-AT, VCP-ATP Metering Self-Test VCP-BT, VCP-AT Transmission Self-Test VCP-BT, VCP-AT, VCP-ATP Dialing Sef Test VCP-BT, VCP-AT Howler Test VCP-BT, VCP-AT Fuse Test VCP-ATP Read Loop and Battery Conditions VCP-BT, VCP-AT, VCP-ATP"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      "none"
    ]
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.5504)

Goldberg Allen

Siblings (8)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.5504.3.3.7.1.1 zhoneTacIndex00
1.3.6.1.4.1.5504.3.3.7.1.2 zhoneTacInterfaceIndex00
1.3.6.1.4.1.5504.3.3.7.1.3 zhoneTacTestMode00
1.3.6.1.4.1.5504.3.3.7.1.5 zhoneTacTestParam100
1.3.6.1.4.1.5504.3.3.7.1.6 zhoneTacTestParam200
1.3.6.1.4.1.5504.3.3.7.1.7 zhoneTacTestParam300
1.3.6.1.4.1.5504.3.3.7.1.8 zhoneTacTestParam400
1.3.6.1.4.1.5504.3.3.7.1.9 zhoneTacTestParam500