Status in source: current.
Names: wtnRxBERHysteresisWindow
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"wtnRxBERHysteresisWindow",
"OBJECT-TYPE",
"SYNTAX",
"SkyZhoneScientificNotation",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"After a wtnBerAlarm trap is sent, it is revoked using the same trap with the condition flag set to false when the modem BER estimate is lower than the set point wtnModemRxBERThresh less this value. Valid values are 0, and the range from 1.0e-1 to 1.0e-12. A value of 0 indicates no hysteresis. BER is assumed accumulated over the last second.\"",
"::=",
"{",
"wtnConfigEntry",
"10",
"}"
],
"syntax_tree": [
[
"row",
"SkyZhoneScientificNotation"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"After a wtnBerAlarm trap is sent, it is revoked using the same trap with the condition flag set to false when the modem BER estimate is lower than the set point wtnModemRxBERThresh less this value. Valid values are 0, and the range from 1.0e-1 to 1.0e-12. A value of 0 indicates no hysteresis. BER is assumed accumulated over the last second."
],
null,
null,
null,
null
]
}
- Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
· Publisher's source file: Source package: observium-community-latest.tar.gz
Vendor MIB copy from the Observium Community archive.
Module: ZHONE-PHY-WTN-RADIO-MIB
See published definition above
Module imports
{'Zhone': ['zhoneRadio', 'zhoneModules'], 'IF-MIB': ['InterfaceIndex'], 'Zhone-TC': ['ZhoneAdminString'], 'SNMPv2-TC': ['TruthValue', 'TimeStamp'], 'SNMPv2-SMI': ['Integer32', 'Gauge32', 'OBJECT-TYPE', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString'], 'ZHONE-RADIO-TC-MIB': ['SkyZhoneScientificNotation', 'SkyZhoneRadioChannelNumber']}
· Download ZHONE-PHY-WTN-RADIO-MIB