Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"wtnMinorAlarmStatus",
"OBJECT-TYPE",
"SYNTAX",
"BITS",
"{",
"rssiDeviation",
"(",
"0",
")",
",",
"iduOOL",
"(",
"1",
")",
",",
"oduTempAlert",
"(",
"2",
")",
",",
"rxBerAlarm",
"(",
"3",
")",
",",
"rxEbnoAlarm",
"(",
"4",
")",
",",
"unused5",
"(",
"5",
")",
",",
"unused6",
"(",
"6",
")",
",",
"unused7",
"(",
"7",
")",
",",
"iduEquipFail",
"(",
"8",
")",
",",
"oduEquipFail",
"(",
"9",
")",
",",
"iduOduLinkFail",
"(",
"10",
")",
",",
"mcChannelFail",
"(",
"11",
")",
",",
"unused12",
"(",
"12",
")",
",",
"unused13",
"(",
"13",
")",
",",
"unused14",
"(",
"14",
")",
",",
"serviceAffected",
"(",
"15",
")",
"}",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"Current radio alarm status details. BIT Hex Decimal BIT NAME Number Value Value ------ ------ ------- ---------------------- 0 0x01 1 RSSI_DEVIATION 1 0x02 2 IDU_OOL 2 0x04 4 ODU_TEMP_ALERT 3 0x08 8 RX_BER_ALARM 4 0x10 16 RX_EBNO_ALARM 5 0x20 32 (reserved) 6 0x40 64 (reserved) 7 0x80 128 (reserved) 8 0x100 256 IDU_EQUIP_FAIL 9 0x200 512 ODU_EQUIP_FAIL 10 0x400 1024 IDU_ODU_LINK_FAIL 11 0x800 2048 MC_CHANNEL_FAIL 12 0x1000 4096 (reserved) 13 0x2000 8192 (reserved) 14 0x4000 16384 (reserved) 15 0x8000 32768 SERVICE_AFFECTED IDU_EQUIP_FAIL - can be caused by: power supply failure, watchdog timeout, or other internal failure on indoor unit. IDU_ODU_LINK_FAIL - can be caused by: IDU/ODU cable failure, bad connection, or equipment failure IDU_OOL - can be caused by: intermittent loss of lock of internal clocks MC_CHANNEL_FAIL - can be caused by: Signal path (air) degradation, or internal equipment failure on near end or far end node. ODU_EQUIP_FAIL - can be caused by: Loss of frequency lock, loss of clock reference, power fault, excessive transmitter power, signal path degradation, frequency drift, or internal failure of equipment in outdoor unit. ODU_TEMP_ALERT - can be caused by: Operating temperature too high or too low. Allowable range of operating temperatures ( in ODU ) are -40C to +65C. RSSI_DEVIATION - can be caused by: signal path (air) degradation, excessive heat buildup at ODU, or frequency drift. RX_BER_ALARM - can be caused by: RF noise burst, fade burst, interference, or internal equipment failure. RX_EBNO_ALARM - can be caused by: Fade, noise burst, or internal equipment stress. The SERVICE_AFFECTING bit should always = 0 on this variable because, by definition, minor alarms may not affect service. \"",
"::=",
"{",
"wtnStatusEntry",
"3",
"}"
],
"syntax_tree": [
[
"BITS",
[
[
"rssiDeviation",
0
],
[
"iduOOL",
1
],
[
"oduTempAlert",
2
],
[
"rxBerAlarm",
3
],
[
"rxEbnoAlarm",
4
],
[
"unused5",
5
],
[
"unused6",
6
],
[
"unused7",
7
],
[
"iduEquipFail",
8
],
[
"oduEquipFail",
9
],
[
"iduOduLinkFail",
10
],
[
"mcChannelFail",
11
],
[
"unused12",
12
],
[
"unused13",
13
],
[
"unused14",
14
],
[
"serviceAffected",
15
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Current radio alarm status details. BIT Hex Decimal BIT NAME Number Value Value ------ ------ ------- ---------------------- 0 0x01 1 RSSI_DEVIATION 1 0x02 2 IDU_OOL 2 0x04 4 ODU_TEMP_ALERT 3 0x08 8 RX_BER_ALARM 4 0x10 16 RX_EBNO_ALARM 5 0x20 32 (reserved) 6 0x40 64 (reserved) 7 0x80 128 (reserved) 8 0x100 256 IDU_EQUIP_FAIL 9 0x200 512 ODU_EQUIP_FAIL 10 0x400 1024 IDU_ODU_LINK_FAIL 11 0x800 2048 MC_CHANNEL_FAIL 12 0x1000 4096 (reserved) 13 0x2000 8192 (reserved) 14 0x4000 16384 (reserved) 15 0x8000 32768 SERVICE_AFFECTED IDU_EQUIP_FAIL - can be caused by: power supply failure, watchdog timeout, or other internal failure on indoor unit. IDU_ODU_LINK_FAIL - can be caused by: IDU/ODU cable failure, bad connection, or equipment failure IDU_OOL - can be caused by: intermittent loss of lock of internal clocks MC_CHANNEL_FAIL - can be caused by: Signal path (air) degradation, or internal equipment failure on near end or far end node. ODU_EQUIP_FAIL - can be caused by: Loss of frequency lock, loss of clock reference, power fault, excessive transmitter power, signal path degradation, frequency drift, or internal failure of equipment in outdoor unit. ODU_TEMP_ALERT - can be caused by: Operating temperature too high or too low. Allowable range of operating temperatures ( in ODU ) are -40C to +65C. RSSI_DEVIATION - can be caused by: signal path (air) degradation, excessive heat buildup at ODU, or frequency drift. RX_BER_ALARM - can be caused by: RF noise burst, fade burst, interference, or internal equipment failure. RX_EBNO_ALARM - can be caused by: Fade, noise burst, or internal equipment stress. The SERVICE_AFFECTING bit should always = 0 on this variable because, by definition, minor alarms may not affect service."
],
null,
null,
null,
null
]
}