Generated Events will be sent to all configured Syslog Collectors, if RemoteLoggingMode is enabled
Sources for this description
Belden, GarrettCom and Hirschmann IT official standalone MIBs
OID reference
1.3.6.1.4.1.553.1.2.1.1.1.1.5
Generated Events will be sent to all configured Syslog Collectors, if RemoteLoggingMode is enabled
Identification
{1 3 6 1 4 1 553 1 2 1 1 1 1 5}
Notes below names come from selected MIB definitions.
| Value | Name and source notes |
|---|---|
| 0 | no Disabled |
| 1 | yes Enabled |
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition. The index encoding is not inferred here.
Published row index: gcEventLogEventCtg, gcEventLogEventId.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.553.1.2.1.1.1.1.5
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
gcEventLogRemoteLoggingMode OBJECT-TYPE
SYNTAX INTEGER {
no (0), -- Disabled
yes (1) -- Enabled
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Generated Events will be sent to all configured Syslog Collectors,
if RemoteLoggingMode is enabled"
::= { gcEventLogEntry 5 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Generated Events will be sent to all configured Syslog Collectors, if RemoteLoggingMode is enabled
Belden, GarrettCom and Hirschmann IT official standalone MIBs
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: gcEventLogRemoteLoggingMode
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"gcEventLogRemoteLoggingMode",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"no",
"(",
"0",
")",
",",
"yes",
"(",
"1",
")",
"}",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"Generated Events will be sent to all configured Syslog Collectors, if RemoteLoggingMode is enabled\"",
"::=",
"{",
"gcEventLogEntry",
"5",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"no",
0
],
[
"yes",
1
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Generated Events will be sent to all configured Syslog Collectors, if RemoteLoggingMode is enabled"
],
null,
null,
null,
null
]
}Module: GARRETTCOM-EVT-SYSLG-MIB
See published definition above
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'TruthValue', 'DisplayString', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'OBJECT-IDENTITY', 'Unsigned32', 'TimeTicks', 'Integer32', 'IpAddress'], 'RFC1155-SMI': ['enterprises'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'GC-MIB-NAMES': ['gcEventMIB']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.553.1.2.1.1.1.1.1 | gcEventLogEventCtg | 0 | 0 | |
| 1.3.6.1.4.1.553.1.2.1.1.1.1.2 | gcEventLogEventId | 0 | 0 | |
| 1.3.6.1.4.1.553.1.2.1.1.1.1.3 | gcEventLogSeverity | 0 | 0 | |
| 1.3.6.1.4.1.553.1.2.1.1.1.1.4 | gcEventLogDescription | 0 | 0 | |
| 1.3.6.1.4.1.553.1.2.1.1.1.1.6 | gcEventLogLocalLoggingTarget | 0 | 0 | |
| 1.3.6.1.4.1.553.1.2.1.1.1.1.7 | gcEventLogTargetConsole | 0 | 0 | |
| 1.3.6.1.4.1.553.1.2.1.1.1.1.8 | gcEventLogTargetBuffer | 0 | 0 | |
| 1.3.6.1.4.1.553.1.2.1.1.1.1.9 | gcEventLogTargetFile | 0 | 0 | |
| 1.3.6.1.4.1.553.1.2.1.1.1.1.10 | gcEventLogTrap | 0 | 0 | |
| 1.3.6.1.4.1.553.1.2.1.1.1.1.11 | gcEventLogClear | 0 | 0 | |
| 1.3.6.1.4.1.553.1.2.1.1.1.1.12 | gcEventLogRowStatus | 0 | 0 |