The ifIndex value of the serial interface or frame relay PVC. 0 (zero) indicates that no serial interface or frame relay PVC has been configured.
Sources for this description
Belden, GarrettCom and Hirschmann IT official standalone MIBs
OID reference
1.3.6.1.4.1.553.15.1.10.1.3.1.1.3
The ifIndex value of the serial interface or frame relay PVC. 0 (zero) indicates that no serial interface or frame relay PVC has been configured.
Identification
{1 3 6 1 4 1 553 15 1 10 1 3 1 1 3}
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
gcTermServChannelIfIndex OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The ifIndex value of the serial interface or frame relay
PVC. 0 (zero) indicates that no serial interface or
frame relay PVC has been configured."
DEFVAL { 0 }
::= { gcTermServEntry 3 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
The ifIndex value of the serial interface or frame relay PVC. 0 (zero) indicates that no serial interface or frame relay PVC has been configured.
Belden, GarrettCom and Hirschmann IT official standalone MIBs
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: gcTermServChannelIfIndex
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"gcTermServChannelIfIndex",
"OBJECT-TYPE",
"SYNTAX",
"InterfaceIndexOrZero",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"The ifIndex value of the serial interface or frame relay PVC. 0 (zero) indicates that no serial interface or frame relay PVC has been configured.\"",
"DEFVAL",
"{",
"0",
"}",
"::=",
"{",
"gcTermServEntry",
"3",
"}"
],
"syntax_tree": [
[
"row",
"InterfaceIndexOrZero"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The ifIndex value of the serial interface or frame relay PVC. 0 (zero) indicates that no serial interface or frame relay PVC has been configured."
],
null,
null,
null,
[
"DEFVAL",
0
]
]
}Module: GARRETTCOM-TERM-SERV-MIB
See published definition above
{'IF-MIB': ['ifEntry', 'ifIndex', 'InterfaceIndexOrZero', 'InterfaceIndex'], 'SNMPv2-TC': ['RowStatus', 'StorageType', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Integer32', 'Unsigned32', 'IpAddress', 'Counter32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'GARRETTCOM-SMI': ['gcAtlantisBaseTerminalServerMib']}Related source files and packages:
Registration