Status in source: unspecified.
Technical details
{
"smi_kind": "MODULE-IDENTITY",
"definition": [
"nnOme40GPmProv",
"MODULE-IDENTITY",
"LAST-UPDATED",
[
"literal",
"223230303930323032303030305a22"
],
"ORGANIZATION",
"\"Nortel\"",
"CONTACT-INFO",
"\" 7035 Ridge Road Hanover, Maryland 21076 United States Toll-free: +1-800-921-1144 Phone: +1-410-694-5700 Fax: +1-410-694-5750 www.ciena.com \"",
"DESCRIPTION",
"\"On Optical Multiservice Edge (OME), this module is used to initialize 40G PM registers and OM Counts. It is also used to set Threshold Level and HccsReference Values, and change Profiles for 40G facilities.\"",
"REVISION",
[
"literal",
"223230303730323032303030305a22"
],
"DESCRIPTION",
"\"Initial Version - created for OME6500 REL 4.0\"",
"REVISION",
[
"literal",
"223230303830323037303030305a22"
],
"DESCRIPTION",
"\"Updating row formatting OME6500 REL 5.1\"",
"REVISION",
[
"literal",
"223230303830323231303030305a22"
],
"DESCRIPTION",
"\"- Updated the monType enum list for OME6500 REL 5.1 - Changed SYNTAX for initShelfEthOmCounts and init40GOmCounts from Binning to Boolean. - Changed MAX-ACCESS from read-write to not-accessible for monType, endpoint,direction and accumTimePeriod.\"",
"REVISION",
[
"literal",
"223230303830333033303030305a22"
],
"DESCRIPTION",
"\"- MonType Enum List Updated: This ENUM list has all supported MonType for OC192, OC768, OTM2. OMT3, ETH10G and WAN - unknown(0) to nill (0)\"",
"REVISION",
[
"literal",
"223230303830353031303030305a22"
],
"DESCRIPTION",
"\" - Changed the DESCRIPTION of nnOme40GPmProv, initShelf40GPmRegisters and initShelfEthOmCounts objects\"",
"REVISION",
[
"literal",
"223230303830383230303030305a22"
],
"DESCRIPTION",
"\" - Added new MonTypes for OME 6500 R5.2 \"",
"REVISION",
[
"literal",
"223230303930323032303030305a22"
],
"DESCRIPTION",
"\" Changed the SYNTAX of threshLevel attribute from Integer32 to DisplayString support the scientific notation type input. E.g.: 5E-10\"",
"::=",
"{",
"nnOme40G",
"4",
"}"
],
"syntax_tree": [
[
"LAST-UPDATED",
"200902020000Z"
],
[
"ORGANIZATION",
"Nortel"
],
[
"CONTACT-INFO",
"7035 Ridge Road Hanover, Maryland 21076 United States Toll-free: +1-800-921-1144 Phone: +1-410-694-5700 Fax: +1-410-694-5750 www.ciena.com"
],
[
"DESCRIPTION",
"On Optical Multiservice Edge (OME), this module is used to initialize 40G PM registers and OM Counts. It is also used to set Threshold Level and HccsReference Values, and change Profiles for 40G facilities."
],
[
"Revisions",
[
[
"200702020000Z",
[
"DESCRIPTION",
"Initial Version - created for OME6500 REL 4.0"
]
],
[
"200802070000Z",
[
"DESCRIPTION",
"Updating row formatting OME6500 REL 5.1"
]
],
[
"200802210000Z",
[
"DESCRIPTION",
"- Updated the monType enum list for OME6500 REL 5.1 - Changed SYNTAX for initShelfEthOmCounts and init40GOmCounts from Binning to Boolean. - Changed MAX-ACCESS from read-write to not-accessible for monType, endpoint,direction and accumTimePeriod."
]
],
[
"200803030000Z",
[
"DESCRIPTION",
"- MonType Enum List Updated: This ENUM list has all supported MonType for OC192, OC768, OTM2. OMT3, ETH10G and WAN - unknown(0) to nill (0)"
]
],
[
"200805010000Z",
[
"DESCRIPTION",
"- Changed the DESCRIPTION of nnOme40GPmProv, initShelf40GPmRegisters and initShelfEthOmCounts objects"
]
],
[
"200808200000Z",
[
"DESCRIPTION",
"- Added new MonTypes for OME 6500 R5.2"
]
],
[
"200902020000Z",
[
"DESCRIPTION",
"Changed the SYNTAX of threshLevel attribute from Integer32 to DisplayString support the scientific notation type input. E.g.: 5E-10"
]
]
]
]
]
}