µçÔ´ÀàÐÍ¡£ (1½»Á÷·ÇÖÇÄÜ 2Ö±Á÷·ÇÖÇÄÜ 3½»Á÷ÖÇÄÜ 4Ö±Á÷ÖÇÄÜ)
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.5651.3.600.7.1.1.2
µçÔ´ÀàÐÍ¡£ (1½»Á÷·ÇÖÇÄÜ 2Ö±Á÷·ÇÖÇÄÜ 3½»Á÷ÖÇÄÜ 4Ö±Á÷ÖÇÄÜ)
Identification
{1 3 6 1 4 1 5651 3 600 7 1 1 2}
| Value | Name |
|---|---|
| 1 | alternating-non-intelligent |
| 2 | direct-non-intelligent |
| 3 | alternating-intelligent |
| 4 | direct-intelligent |
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.
In MAIPU-SYSTEM-MIB, the row index powerIndex is declared as INTEGER. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.5651.3.600.7.1.1.2.<powerIndex>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.5651.3.600.7.1.1.2
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
powerType OBJECT-TYPE
SYNTAX INTEGER{
alternating-non-intelligent(1),
direct-non-intelligent(2),
alternating-intelligent(3),
direct-intelligent(4)
}
ACCESS read-only
STATUS current
DESCRIPTION
"µçÔ´ÀàÐÍ¡£ (1½»Á÷·ÇÖÇÄÜ 2Ö±Á÷·ÇÖÇÄÜ 3½»Á÷ÖÇÄÜ 4Ö±Á÷ÖÇÄÜ)"
::= {powerInfoEntry 2}
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
µçÔ´ÀàÐÍ¡£ (1½»Á÷·ÇÖÇÄÜ 2Ö±Á÷·ÇÖÇÄÜ 3½»Á÷ÖÇÄÜ 4Ö±Á÷ÖÇÄÜ)
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: powerType
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"powerType",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"alternating-non-intelligent",
"(",
"1",
")",
",",
"direct-non-intelligent",
"(",
"2",
")",
",",
"alternating-intelligent",
"(",
"3",
")",
",",
"direct-intelligent",
"(",
"4",
")",
"}",
"ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"µçÔ´ÀàÐÍ¡£ (1½»Á÷·ÇÖÇÄÜ 2Ö±Á÷·ÇÖÇÄÜ 3½»Á÷ÖÇÄÜ 4Ö±Á÷ÖÇÄÜ)\"",
"::=",
"{",
"powerInfoEntry",
"2",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"alternating-non-intelligent",
1
],
[
"direct-non-intelligent",
2
],
[
"alternating-intelligent",
3
],
[
"direct-intelligent",
4
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"µçÔ´ÀàÐÍ¡£ (1½»Á÷·ÇÖÇÄÜ 2Ö±Á÷·ÇÖÇÄÜ 3½»Á÷ÖÇÄÜ 4Ö±Á÷ÖÇÄÜ)"
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: MAIPU-SYSTEM-MIB
See published definition above
{'MAIPU-SMI': ['mpMgmt'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'TruthValue', 'MacAddress', 'RowStatus', 'DisplayString', 'DateAndTime'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises', 'Counter32', 'Gauge32', 'Integer32', 'Unsigned32', 'TimeTicks', 'IpAddress', 'Counter64'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.5651.3.600.7.1.1.1 | powerIndex | 0 | 0 | |
| 1.3.6.1.4.1.5651.3.600.7.1.1.3 | powerDescription | 0 | 0 | |
| 1.3.6.1.4.1.5651.3.600.7.1.1.4 | powerSerialNumber | 0 | 0 | |
| 1.3.6.1.4.1.5651.3.600.7.1.1.5 | powerCMMSoftwareVersion | 0 | 0 | |
| 1.3.6.1.4.1.5651.3.600.7.1.1.6 | powerCMMHardwareVersion | 0 | 0 | |
| 1.3.6.1.4.1.5651.3.600.7.1.1.7 | powerCMMMonitorVersion | 0 | 0 | |
| 1.3.6.1.4.1.5651.3.600.7.1.1.8 | powerOnlineStatus | 0 | 0 | |
| 1.3.6.1.4.1.5651.3.600.7.1.1.9 | powerWorkingStatus | 0 | 0 | |
| 1.3.6.1.4.1.5651.3.600.7.1.1.10 | powerAlarmStatus | 0 | 0 | |
| 1.3.6.1.4.1.5651.3.600.7.1.1.11 | powerVoltageInput | 0 | 0 | |
| 1.3.6.1.4.1.5651.3.600.7.1.1.12 | powerVoltageOutput | 0 | 0 | |
| 1.3.6.1.4.1.5651.3.600.7.1.1.13 | powerCurrentInput | 0 | 0 | |
| 1.3.6.1.4.1.5651.3.600.7.1.1.14 | powerCurrentOutput | 0 | 0 |