nag — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
MIB module for SNR-S5XXX series switches
{1 3 6 1 4 1 57206}
MIB module for SNR-S5XXX series switches
NAGTECH LLC
Status in source: unspecified.
Names: nag
{
"smi_kind": "MODULE-IDENTITY",
"definition": [
"nag",
"MODULE-IDENTITY",
"LAST-UPDATED",
[
"literal",
"223230323530363138313230305a22"
],
"ORGANIZATION",
"\"NAG\"",
"CONTACT-INFO",
"\"support@nag.ru\"",
"DESCRIPTION",
"\"MIB module for SNR-S5XXX series switches\"",
"REVISION",
[
"literal",
"223230323530363138313230305a22"
],
"DESCRIPTION",
"\"eNOS 1.16.0 1. Add isolatePortCfg(7.100.100) object\"",
"REVISION",
[
"literal",
"223230323530333132313230305a22"
],
"DESCRIPTION",
"\"eNOS 1.15.0 1. Add acl(7.100.10.1) object 2. Add dcscm(7.100.20) object 3. Add loopbackDetecIntervalTime(7.100.3.4.2) object 4. Add loopbackDetecCtrlTable(7.100.3.4.3) object 5. Add loopbackDetecBlockCtrlRecovery(7.100.3.4.20) object 6. Add loopbackDetectEnableTable(7.100.3.4.21) object 7. Add errdisableTimeoutEnable(7.100.3.30) object 8. Add errdisableTimeoutInterval(7.100.3.31) object 9. Add mode 'private-vlan host' in portMode object 10. Add mode 'private-vlan promiscuous' in portMode object 11. Add loopBackDetect-trap(7.101.112) object\"",
"REVISION",
[
"literal",
"223230323530323034313230305a22"
],
"DESCRIPTION",
"\"eNOS 1.14.0 1. Add switchCPUOneMinuteIdle(7.100.1.11.25) object 2. Add switchFlashOccupiedSizeInBytes(7.100.1.11.15) object 3. Add portClearCountTable(7.100.3.15) object 4. Add slotNum(7.100.3.2.1.4) object 5. Add mode 'full2500' in speedDuplex object\"",
"REVISION",
[
"literal",
"223230323431323036313230305a22"
],
"DESCRIPTION",
"\"eNOS 1.13.0 1. Add macNotifications(7.101.107) object 2. Add stormControlTable(7.100.3.3) object 3. Add stormControlActionTable(7.100.3.20) object 4. Add bandwidthControlStatus(7.100.3.2.1.7) object 5. Add maxBandwidth(7.100.3.2.1.8) object 6. Add receiveBandwidth(7.100.3.2.1.9) object 7. Add transmitBandwidth(7.100.3.2.1.10) object 8. Add macNotificationMib(7.100.33) object\"",
"REVISION",
[
"literal",
"223230323431313133313230305a22"
],
"DESCRIPTION",
"\"eNOS 1.12.0 1. Add sysWriteConfig(7.100.1.6) object 2. Add switchFlashSizeInBytes(7.100.1.11.14) object 3. Add priDhcp(7.100.13) object\"",
"REVISION",
[
"literal",
"223230323430393137313230305a22"
],
"DESCRIPTION",
"\"eNOS 1.11.0 1. Add portSecurity(7.100.32) object 2. Add priPoeConfig(7.100.26.10) object\"",
"REVISION",
[
"literal",
"223230323430363230313230305a22"
],
"DESCRIPTION",
"\"eNOS 1.9.0 1. Add poeCurrentPower(7.100.26.6) object 2. Add sysPowerStateTable(7.100.1.7) object\"",
"::=",
"{",
"enterprises",
"57206",
"}"
],
"syntax_tree": [
[
"LAST-UPDATED",
"202506181200Z"
],
[
"ORGANIZATION",
"NAG"
],
[
"CONTACT-INFO",
"support@nag.ru"
],
[
"DESCRIPTION",
"MIB module for SNR-S5XXX series switches"
],
[
"Revisions",
[
[
"202506181200Z",
[
"DESCRIPTION",
"eNOS 1.16.0 1. Add isolatePortCfg(7.100.100) object"
]
],
[
"202503121200Z",
[
"DESCRIPTION",
"eNOS 1.15.0 1. Add acl(7.100.10.1) object 2. Add dcscm(7.100.20) object 3. Add loopbackDetecIntervalTime(7.100.3.4.2) object 4. Add loopbackDetecCtrlTable(7.100.3.4.3) object 5. Add loopbackDetecBlockCtrlRecovery(7.100.3.4.20) object 6. Add loopbackDetectEnableTable(7.100.3.4.21) object 7. Add errdisableTimeoutEnable(7.100.3.30) object 8. Add errdisableTimeoutInterval(7.100.3.31) object 9. Add mode 'private-vlan host' in portMode object 10. Add mode 'private-vlan promiscuous' in portMode object 11. Add loopBackDetect-trap(7.101.112) object"
]
],
[
"202502041200Z",
[
"DESCRIPTION",
"eNOS 1.14.0 1. Add switchCPUOneMinuteIdle(7.100.1.11.25) object 2. Add switchFlashOccupiedSizeInBytes(7.100.1.11.15) object 3. Add portClearCountTable(7.100.3.15) object 4. Add slotNum(7.100.3.2.1.4) object 5. Add mode 'full2500' in speedDuplex object"
]
],
[
"202412061200Z",
[
"DESCRIPTION",
"eNOS 1.13.0 1. Add macNotifications(7.101.107) object 2. Add stormControlTable(7.100.3.3) object 3. Add stormControlActionTable(7.100.3.20) object 4. Add bandwidthControlStatus(7.100.3.2.1.7) object 5. Add maxBandwidth(7.100.3.2.1.8) object 6. Add receiveBandwidth(7.100.3.2.1.9) object 7. Add transmitBandwidth(7.100.3.2.1.10) object 8. Add macNotificationMib(7.100.33) object"
]
],
[
"202411131200Z",
[
"DESCRIPTION",
"eNOS 1.12.0 1. Add sysWriteConfig(7.100.1.6) object 2. Add switchFlashSizeInBytes(7.100.1.11.14) object 3. Add priDhcp(7.100.13) object"
]
],
[
"202409171200Z",
[
"DESCRIPTION",
"eNOS 1.11.0 1. Add portSecurity(7.100.32) object 2. Add priPoeConfig(7.100.26.10) object"
]
],
[
"202406201200Z",
[
"DESCRIPTION",
"eNOS 1.9.0 1. Add poeCurrentPower(7.100.26.6) object 2. Add sysPowerStateTable(7.100.1.7) object"
]
]
]
]
]
}Vendor MIB copy from the Observium Community archive.
Module: NAG-MIB
nag MODULE-IDENTITY
LAST-UPDATED "202506181200Z" -- Jun 18, 2025
ORGANIZATION "NAG"
CONTACT-INFO "support@nag.ru"
DESCRIPTION "MIB module for SNR-S5XXX series switches"
REVISION "202506181200Z" -- Jun 18, 2025
DESCRIPTION "eNOS 1.16.0
1. Add isolatePortCfg(7.100.100) object"
REVISION "202503121200Z" -- Mar 12, 2025
DESCRIPTION "eNOS 1.15.0
1. Add acl(7.100.10.1) object
2. Add dcscm(7.100.20) object
3. Add loopbackDetecIntervalTime(7.100.3.4.2) object
4. Add loopbackDetecCtrlTable(7.100.3.4.3) object
5. Add loopbackDetecBlockCtrlRecovery(7.100.3.4.20) object
6. Add loopbackDetectEnableTable(7.100.3.4.21) object
7. Add errdisableTimeoutEnable(7.100.3.30) object
8. Add errdisableTimeoutInterval(7.100.3.31) object
9. Add mode 'private-vlan host' in portMode object
10. Add mode 'private-vlan promiscuous' in portMode object
11. Add loopBackDetect-trap(7.101.112) object"
REVISION "202502041200Z" -- Feb 4, 2025
DESCRIPTION "eNOS 1.14.0
1. Add switchCPUOneMinuteIdle(7.100.1.11.25) object
2. Add switchFlashOccupiedSizeInBytes(7.100.1.11.15) object
3. Add portClearCountTable(7.100.3.15) object
4. Add slotNum(7.100.3.2.1.4) object
5. Add mode 'full2500' in speedDuplex object"
REVISION "202412061200Z" -- Dec 6, 2024
DESCRIPTION "eNOS 1.13.0
1. Add macNotifications(7.101.107) object
2. Add stormControlTable(7.100.3.3) object
3. Add stormControlActionTable(7.100.3.20) object
4. Add bandwidthControlStatus(7.100.3.2.1.7) object
5. Add maxBandwidth(7.100.3.2.1.8) object
6. Add receiveBandwidth(7.100.3.2.1.9) object
7. Add transmitBandwidth(7.100.3.2.1.10) object
8. Add macNotificationMib(7.100.33) object"
REVISION "202411131200Z" -- Nov 13, 2024
DESCRIPTION "eNOS 1.12.0
1. Add sysWriteConfig(7.100.1.6) object
2. Add switchFlashSizeInBytes(7.100.1.11.14) object
3. Add priDhcp(7.100.13) object"
REVISION "202409171200Z" -- Sept 17, 2024
DESCRIPTION "eNOS 1.11.0
1. Add portSecurity(7.100.32) object
2. Add priPoeConfig(7.100.26.10) object"
REVISION "202406201200Z" -- June 20, 2024
DESCRIPTION "eNOS 1.9.0
1. Add poeCurrentPower(7.100.26.6) object
2. Add sysPowerStateTable(7.100.1.7) object"
::= { enterprises 57206 }{'RFC-1215': ['TRAP-TYPE'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'RowStatus', 'TimeStamp', 'TruthValue'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'MODULE-IDENTITY', 'OBJECT-TYPE', 'mib-2', 'Integer32', 'Counter32', 'Counter64', 'Gauge32', 'Unsigned32', 'NOTIFICATION-TYPE', 'IpAddress', 'TimeTicks', 'experimental'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['ifIndex'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP']}Related source files and packages:
Downloaded: 2026-10-24T02:14:26.010162+00:00.
Status in source: unspecified.
{
"contact": "Petr Milenin",
"organization": "NAGTECH LLC",
"email_as_published": "p.milenin&nagtech.ru"
}Downloaded: 2026-10-24T04:19:29.314233+00:00.
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.57206.7 | snr | 3 | 325 |
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.44500 | 44500 | 0 | 0 | CHRONOTRACK SYSTEMS CORP. |
| 1.3.6.1.4.1.44501 | 44501 | 0 | 0 | NuLEDs, Inc. |
| 1.3.6.1.4.1.44502 | 44502 | 0 | 0 | SmartCast GmbH |
| 1.3.6.1.4.1.44503 | 44503 | 0 | 0 | MDLIVE Inc. |
| 1.3.6.1.4.1.44504 | 44504 | 0 | 0 | Evilcats Organization |
| 1.3.6.1.4.1.44505 | 44505 | 0 | 0 | Ideum Group, Inc |
| 1.3.6.1.4.1.44506 | 44506 | 0 | 0 | Consulta Network Security AB |
| 1.3.6.1.4.1.44507 | 44507 | 0 | 0 | Northwest Alabama Cancer Center, PC |
| 1.3.6.1.4.1.44508 | 44508 | 0 | 0 | Vigilant Applications Limited |
| 1.3.6.1.4.1.44509 | 44509 | 0 | 0 | CompTek |
| 1.3.6.1.4.1.44510 | 44510 | 0 | 0 | FJ Consultant |
| 1.3.6.1.4.1.44511 | 44511 | 0 | 0 | Rudolf Wild GmbH & Co. KG |
| 1.3.6.1.4.1.44512 | 44512 | 0 | 0 | iptronix srl |
| 1.3.6.1.4.1.44513 | 44513 | 0 | 0 | Essener Versorgungs- und Verkehrsgesellschaft mbH (EVV) |
| 1.3.6.1.4.1.44514 | 44514 | 0 | 0 | bremersee.org |
| 1.3.6.1.4.1.44515 | 44515 | 0 | 0 | Griesson - de Beukelaer GmbH & Co. KG |
| 1.3.6.1.4.1.44516 | 44516 | 0 | 0 | ETES GmbH |
| 1.3.6.1.4.1.44517 | 44517 | 0 | 0 | Virgil Grigoras |
| 1.3.6.1.4.1.44518 | 44518 | 0 | 0 | EUROSELL SPA |
| 1.3.6.1.4.1.44519 | 44519 | 0 | 0 | US Railroad Retirement Board |
| 1.3.6.1.4.1.44520 | 44520 | 0 | 0 | Consolidated Information Systems |
| 1.3.6.1.4.1.44521 | 44521 | 0 | 0 | WUNDERVOLL NETWORKS |
| 1.3.6.1.4.1.44522 | 44522 | 0 | 0 | Information Technology Solutions Laboratory |
| 1.3.6.1.4.1.44523 | 44523 | 0 | 0 | NetBeez |
| 1.3.6.1.4.1.44524 | 44524 | 0 | 0 | Research & Development Center "Vulkan" LLC |
| 1.3.6.1.4.1.44525 | 44525 | 0 | 0 | Breast Surgery of Tulsa |
| 1.3.6.1.4.1.44526 | 44526 | 0 | 0 | Carta Solutions Processing Services Corp |
| 1.3.6.1.4.1.44527 | 44527 | 0 | 0 | Marco Dominguez |
| 1.3.6.1.4.1.44528 | 44528 | 0 | 0 | Uriel Technologies |
| 1.3.6.1.4.1.44529 | 44529 | 0 | 0 | One Call Care Management |
| 1.3.6.1.4.1.44530 | 44530 | 0 | 0 | Alphapower Ltd. |
| 1.3.6.1.4.1.44531 | 44531 | 0 | 0 | Renfell Engineering Pty Ltd |
| 1.3.6.1.4.1.44532 | 44532 | 0 | 0 | Sage Electronic Engineering, LLC |
| 1.3.6.1.4.1.44533 | 44533 | 0 | 0 | Digital Barriers |
| 1.3.6.1.4.1.44534 | 44534 | 0 | 0 | Weybourne Partners LLP |
| 1.3.6.1.4.1.44535 | 44535 | 0 | 0 | TSAT AS |
| 1.3.6.1.4.1.44536 | 44536 | 0 | 0 | True Partners Consulting LLC |
| 1.3.6.1.4.1.44537 | 44537 | 0 | 0 | Elauwit Networks, LLC |
| 1.3.6.1.4.1.44538 | 44538 | 0 | 0 | Providius Corp |
| 1.3.6.1.4.1.44539 | 44539 | 0 | 0 | Safe Patient Systems Ltd |
| 1.3.6.1.4.1.44540 | 44540 | 0 | 0 | Bond Enterprises |
| 1.3.6.1.4.1.44541 | 44541 | 0 | 0 | FeiTian United (Beijing) System Technology Co.,Ltd. |
| 1.3.6.1.4.1.44542 | 44542 | 0 | 0 | VdS Schadenverhütung GmbH |
| 1.3.6.1.4.1.44543 | 44543 | 0 | 0 | Viesti Networks Oy |
| 1.3.6.1.4.1.44544 | 44544 | 0 | 0 | SANEF-ITS |
| 1.3.6.1.4.1.44545 | 44545 | 0 | 0 | K-LAGAN España S.L. |
| 1.3.6.1.4.1.44546 | 44546 | 0 | 0 | Harp Visual Communications Ltd |
| 1.3.6.1.4.1.44547 | 44547 | 0 | 0 | YMOR Group B.V. |
| 1.3.6.1.4.1.44548 | 44548 | 0 | 0 | Centrale Ashton Inc. |
| 1.3.6.1.4.1.44549 | 44549 | 0 | 0 | ELECTRIS |