nag — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
MIB module for SNR-S5XXX series switches
{1 3 6 1 4 1 57206}
MIB module for SNR-S5XXX series switches
NAGTECH LLC
Status in source: unspecified.
Names: nag
{
"smi_kind": "MODULE-IDENTITY",
"definition": [
"nag",
"MODULE-IDENTITY",
"LAST-UPDATED",
[
"literal",
"223230323530363138313230305a22"
],
"ORGANIZATION",
"\"NAG\"",
"CONTACT-INFO",
"\"support@nag.ru\"",
"DESCRIPTION",
"\"MIB module for SNR-S5XXX series switches\"",
"REVISION",
[
"literal",
"223230323530363138313230305a22"
],
"DESCRIPTION",
"\"eNOS 1.16.0 1. Add isolatePortCfg(7.100.100) object\"",
"REVISION",
[
"literal",
"223230323530333132313230305a22"
],
"DESCRIPTION",
"\"eNOS 1.15.0 1. Add acl(7.100.10.1) object 2. Add dcscm(7.100.20) object 3. Add loopbackDetecIntervalTime(7.100.3.4.2) object 4. Add loopbackDetecCtrlTable(7.100.3.4.3) object 5. Add loopbackDetecBlockCtrlRecovery(7.100.3.4.20) object 6. Add loopbackDetectEnableTable(7.100.3.4.21) object 7. Add errdisableTimeoutEnable(7.100.3.30) object 8. Add errdisableTimeoutInterval(7.100.3.31) object 9. Add mode 'private-vlan host' in portMode object 10. Add mode 'private-vlan promiscuous' in portMode object 11. Add loopBackDetect-trap(7.101.112) object\"",
"REVISION",
[
"literal",
"223230323530323034313230305a22"
],
"DESCRIPTION",
"\"eNOS 1.14.0 1. Add switchCPUOneMinuteIdle(7.100.1.11.25) object 2. Add switchFlashOccupiedSizeInBytes(7.100.1.11.15) object 3. Add portClearCountTable(7.100.3.15) object 4. Add slotNum(7.100.3.2.1.4) object 5. Add mode 'full2500' in speedDuplex object\"",
"REVISION",
[
"literal",
"223230323431323036313230305a22"
],
"DESCRIPTION",
"\"eNOS 1.13.0 1. Add macNotifications(7.101.107) object 2. Add stormControlTable(7.100.3.3) object 3. Add stormControlActionTable(7.100.3.20) object 4. Add bandwidthControlStatus(7.100.3.2.1.7) object 5. Add maxBandwidth(7.100.3.2.1.8) object 6. Add receiveBandwidth(7.100.3.2.1.9) object 7. Add transmitBandwidth(7.100.3.2.1.10) object 8. Add macNotificationMib(7.100.33) object\"",
"REVISION",
[
"literal",
"223230323431313133313230305a22"
],
"DESCRIPTION",
"\"eNOS 1.12.0 1. Add sysWriteConfig(7.100.1.6) object 2. Add switchFlashSizeInBytes(7.100.1.11.14) object 3. Add priDhcp(7.100.13) object\"",
"REVISION",
[
"literal",
"223230323430393137313230305a22"
],
"DESCRIPTION",
"\"eNOS 1.11.0 1. Add portSecurity(7.100.32) object 2. Add priPoeConfig(7.100.26.10) object\"",
"REVISION",
[
"literal",
"223230323430363230313230305a22"
],
"DESCRIPTION",
"\"eNOS 1.9.0 1. Add poeCurrentPower(7.100.26.6) object 2. Add sysPowerStateTable(7.100.1.7) object\"",
"::=",
"{",
"enterprises",
"57206",
"}"
],
"syntax_tree": [
[
"LAST-UPDATED",
"202506181200Z"
],
[
"ORGANIZATION",
"NAG"
],
[
"CONTACT-INFO",
"support@nag.ru"
],
[
"DESCRIPTION",
"MIB module for SNR-S5XXX series switches"
],
[
"Revisions",
[
[
"202506181200Z",
[
"DESCRIPTION",
"eNOS 1.16.0 1. Add isolatePortCfg(7.100.100) object"
]
],
[
"202503121200Z",
[
"DESCRIPTION",
"eNOS 1.15.0 1. Add acl(7.100.10.1) object 2. Add dcscm(7.100.20) object 3. Add loopbackDetecIntervalTime(7.100.3.4.2) object 4. Add loopbackDetecCtrlTable(7.100.3.4.3) object 5. Add loopbackDetecBlockCtrlRecovery(7.100.3.4.20) object 6. Add loopbackDetectEnableTable(7.100.3.4.21) object 7. Add errdisableTimeoutEnable(7.100.3.30) object 8. Add errdisableTimeoutInterval(7.100.3.31) object 9. Add mode 'private-vlan host' in portMode object 10. Add mode 'private-vlan promiscuous' in portMode object 11. Add loopBackDetect-trap(7.101.112) object"
]
],
[
"202502041200Z",
[
"DESCRIPTION",
"eNOS 1.14.0 1. Add switchCPUOneMinuteIdle(7.100.1.11.25) object 2. Add switchFlashOccupiedSizeInBytes(7.100.1.11.15) object 3. Add portClearCountTable(7.100.3.15) object 4. Add slotNum(7.100.3.2.1.4) object 5. Add mode 'full2500' in speedDuplex object"
]
],
[
"202412061200Z",
[
"DESCRIPTION",
"eNOS 1.13.0 1. Add macNotifications(7.101.107) object 2. Add stormControlTable(7.100.3.3) object 3. Add stormControlActionTable(7.100.3.20) object 4. Add bandwidthControlStatus(7.100.3.2.1.7) object 5. Add maxBandwidth(7.100.3.2.1.8) object 6. Add receiveBandwidth(7.100.3.2.1.9) object 7. Add transmitBandwidth(7.100.3.2.1.10) object 8. Add macNotificationMib(7.100.33) object"
]
],
[
"202411131200Z",
[
"DESCRIPTION",
"eNOS 1.12.0 1. Add sysWriteConfig(7.100.1.6) object 2. Add switchFlashSizeInBytes(7.100.1.11.14) object 3. Add priDhcp(7.100.13) object"
]
],
[
"202409171200Z",
[
"DESCRIPTION",
"eNOS 1.11.0 1. Add portSecurity(7.100.32) object 2. Add priPoeConfig(7.100.26.10) object"
]
],
[
"202406201200Z",
[
"DESCRIPTION",
"eNOS 1.9.0 1. Add poeCurrentPower(7.100.26.6) object 2. Add sysPowerStateTable(7.100.1.7) object"
]
]
]
]
]
}Vendor MIB copy from the Observium Community archive.
Module: NAG-MIB
nag MODULE-IDENTITY
LAST-UPDATED "202506181200Z" -- Jun 18, 2025
ORGANIZATION "NAG"
CONTACT-INFO "support@nag.ru"
DESCRIPTION "MIB module for SNR-S5XXX series switches"
REVISION "202506181200Z" -- Jun 18, 2025
DESCRIPTION "eNOS 1.16.0
1. Add isolatePortCfg(7.100.100) object"
REVISION "202503121200Z" -- Mar 12, 2025
DESCRIPTION "eNOS 1.15.0
1. Add acl(7.100.10.1) object
2. Add dcscm(7.100.20) object
3. Add loopbackDetecIntervalTime(7.100.3.4.2) object
4. Add loopbackDetecCtrlTable(7.100.3.4.3) object
5. Add loopbackDetecBlockCtrlRecovery(7.100.3.4.20) object
6. Add loopbackDetectEnableTable(7.100.3.4.21) object
7. Add errdisableTimeoutEnable(7.100.3.30) object
8. Add errdisableTimeoutInterval(7.100.3.31) object
9. Add mode 'private-vlan host' in portMode object
10. Add mode 'private-vlan promiscuous' in portMode object
11. Add loopBackDetect-trap(7.101.112) object"
REVISION "202502041200Z" -- Feb 4, 2025
DESCRIPTION "eNOS 1.14.0
1. Add switchCPUOneMinuteIdle(7.100.1.11.25) object
2. Add switchFlashOccupiedSizeInBytes(7.100.1.11.15) object
3. Add portClearCountTable(7.100.3.15) object
4. Add slotNum(7.100.3.2.1.4) object
5. Add mode 'full2500' in speedDuplex object"
REVISION "202412061200Z" -- Dec 6, 2024
DESCRIPTION "eNOS 1.13.0
1. Add macNotifications(7.101.107) object
2. Add stormControlTable(7.100.3.3) object
3. Add stormControlActionTable(7.100.3.20) object
4. Add bandwidthControlStatus(7.100.3.2.1.7) object
5. Add maxBandwidth(7.100.3.2.1.8) object
6. Add receiveBandwidth(7.100.3.2.1.9) object
7. Add transmitBandwidth(7.100.3.2.1.10) object
8. Add macNotificationMib(7.100.33) object"
REVISION "202411131200Z" -- Nov 13, 2024
DESCRIPTION "eNOS 1.12.0
1. Add sysWriteConfig(7.100.1.6) object
2. Add switchFlashSizeInBytes(7.100.1.11.14) object
3. Add priDhcp(7.100.13) object"
REVISION "202409171200Z" -- Sept 17, 2024
DESCRIPTION "eNOS 1.11.0
1. Add portSecurity(7.100.32) object
2. Add priPoeConfig(7.100.26.10) object"
REVISION "202406201200Z" -- June 20, 2024
DESCRIPTION "eNOS 1.9.0
1. Add poeCurrentPower(7.100.26.6) object
2. Add sysPowerStateTable(7.100.1.7) object"
::= { enterprises 57206 }{'RFC-1215': ['TRAP-TYPE'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'RowStatus', 'TimeStamp', 'TruthValue'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'MODULE-IDENTITY', 'OBJECT-TYPE', 'mib-2', 'Integer32', 'Counter32', 'Counter64', 'Gauge32', 'Unsigned32', 'NOTIFICATION-TYPE', 'IpAddress', 'TimeTicks', 'experimental'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['ifIndex'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP']}Related source files and packages:
Downloaded: 2026-10-24T02:14:26.010162+00:00.
Status in source: unspecified.
{
"contact": "Petr Milenin",
"organization": "NAGTECH LLC",
"email_as_published": "p.milenin&nagtech.ru"
}Downloaded: 2026-10-24T04:19:29.314233+00:00.
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.57206.7 | snr | 3 | 325 |
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.45850 | 45850 | 0 | 0 | Eternity's Touch, Inc. |
| 1.3.6.1.4.1.45851 | 45851 | 0 | 0 | Unfallkasse Baden-Wuerttemberg |
| 1.3.6.1.4.1.45852 | 45852 | 0 | 0 | Miami Hematology and Oncology Associates |
| 1.3.6.1.4.1.45853 | 45853 | 0 | 0 | Jaguar Land Rover Limited |
| 1.3.6.1.4.1.45854 | 45854 | 0 | 0 | Cell Technology Ltd. |
| 1.3.6.1.4.1.45855 | 45855 | 0 | 0 | Intracom Asia Co., Ltd. |
| 1.3.6.1.4.1.45856 | 45856 | 0 | 0 | Mie Prefectural Government |
| 1.3.6.1.4.1.45857 | 45857 | 3 | 11 | Kailow Graphic A/S |
| 1.3.6.1.4.1.45858 | 45858 | 0 | 0 | Cifernet Inc. |
| 1.3.6.1.4.1.45859 | 45859 | 0 | 0 | Pylo.Net |
| 1.3.6.1.4.1.45860 | 45860 | 0 | 0 | Exel Technology Group |
| 1.3.6.1.4.1.45861 | 45861 | 0 | 0 | Research Associates of Syracuse, Inc. |
| 1.3.6.1.4.1.45862 | 45862 | 0 | 0 | Apost Ltd. |
| 1.3.6.1.4.1.45863 | 45863 | 0 | 0 | La Folie Boutique |
| 1.3.6.1.4.1.45864 | 45864 | 0 | 0 | Direction Generale de l'Education et des Enseignements |
| 1.3.6.1.4.1.45865 | 45865 | 0 | 0 | Shouei electric,co |
| 1.3.6.1.4.1.45866 | 45866 | 0 | 0 | GlobalPME |
| 1.3.6.1.4.1.45867 | 45867 | 0 | 0 | LUKOIL Bulgaria Ltd. |
| 1.3.6.1.4.1.45868 | 45868 | 0 | 0 | Skywire Technologies |
| 1.3.6.1.4.1.45869 | 45869 | 0 | 0 | POET GmbH |
| 1.3.6.1.4.1.45870 | 45870 | 0 | 0 | Fraunhofer Institute for Secure Information Technology SIT |
| 1.3.6.1.4.1.45871 | 45871 | 0 | 0 | FATECH Electronic |
| 1.3.6.1.4.1.45872 | 45872 | 0 | 0 | Institut National de l'Audiovisuel |
| 1.3.6.1.4.1.45873 | 45873 | 0 | 0 | Instituto Federal Catarinense |
| 1.3.6.1.4.1.45874 | 45874 | 0 | 0 | Coencorp |
| 1.3.6.1.4.1.45875 | 45875 | 0 | 0 | Edward H. Kaplan,M.D. and Assoc. |
| 1.3.6.1.4.1.45876 | 45876 | 0 | 0 | Jetson Systems, LLC |
| 1.3.6.1.4.1.45877 | 45877 | 0 | 0 | Intelligent Homes |
| 1.3.6.1.4.1.45878 | 45878 | 0 | 0 | vesperal.eu |
| 1.3.6.1.4.1.45879 | 45879 | 0 | 0 | Université de Lille |
| 1.3.6.1.4.1.45880 | 45880 | 0 | 0 | West-Ward Pharmaceuticals Corp |
| 1.3.6.1.4.1.45881 | 45881 | 0 | 0 | 2Lconsult |
| 1.3.6.1.4.1.45882 | 45882 | 0 | 0 | Global Voice Group, S.A. |
| 1.3.6.1.4.1.45883 | 45883 | 0 | 0 | EagleBurgmann Germany GmbH & Co. KG |
| 1.3.6.1.4.1.45884 | 45884 | 0 | 0 | AuthClub Inc |
| 1.3.6.1.4.1.45885 | 45885 | 0 | 0 | Cesbo Ltd. |
| 1.3.6.1.4.1.45886 | 45886 | 0 | 0 | Connect-Omsk, Ltd. |
| 1.3.6.1.4.1.45887 | 45887 | 0 | 0 | Arke Telekom Ltd. Sti. |
| 1.3.6.1.4.1.45888 | 45888 | 0 | 0 | Jawset Visual Computing |
| 1.3.6.1.4.1.45889 | 45889 | 0 | 0 | TechMIC electronics |
| 1.3.6.1.4.1.45890 | 45890 | 0 | 0 | Sys-City Co., Ltd. |
| 1.3.6.1.4.1.45891 | 45891 | 0 | 0 | Pandora A/S |
| 1.3.6.1.4.1.45892 | 45892 | 0 | 0 | Combination AB |
| 1.3.6.1.4.1.45893 | 45893 | 0 | 0 | PSTech |
| 1.3.6.1.4.1.45894 | 45894 | 0 | 0 | SysAdmin-CR Sociedad Anonima |