nag — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
MIB module for SNR-S5XXX series switches
{1 3 6 1 4 1 57206}
MIB module for SNR-S5XXX series switches
NAGTECH LLC
Status in source: unspecified.
Names: nag
{
"smi_kind": "MODULE-IDENTITY",
"definition": [
"nag",
"MODULE-IDENTITY",
"LAST-UPDATED",
[
"literal",
"223230323530363138313230305a22"
],
"ORGANIZATION",
"\"NAG\"",
"CONTACT-INFO",
"\"support@nag.ru\"",
"DESCRIPTION",
"\"MIB module for SNR-S5XXX series switches\"",
"REVISION",
[
"literal",
"223230323530363138313230305a22"
],
"DESCRIPTION",
"\"eNOS 1.16.0 1. Add isolatePortCfg(7.100.100) object\"",
"REVISION",
[
"literal",
"223230323530333132313230305a22"
],
"DESCRIPTION",
"\"eNOS 1.15.0 1. Add acl(7.100.10.1) object 2. Add dcscm(7.100.20) object 3. Add loopbackDetecIntervalTime(7.100.3.4.2) object 4. Add loopbackDetecCtrlTable(7.100.3.4.3) object 5. Add loopbackDetecBlockCtrlRecovery(7.100.3.4.20) object 6. Add loopbackDetectEnableTable(7.100.3.4.21) object 7. Add errdisableTimeoutEnable(7.100.3.30) object 8. Add errdisableTimeoutInterval(7.100.3.31) object 9. Add mode 'private-vlan host' in portMode object 10. Add mode 'private-vlan promiscuous' in portMode object 11. Add loopBackDetect-trap(7.101.112) object\"",
"REVISION",
[
"literal",
"223230323530323034313230305a22"
],
"DESCRIPTION",
"\"eNOS 1.14.0 1. Add switchCPUOneMinuteIdle(7.100.1.11.25) object 2. Add switchFlashOccupiedSizeInBytes(7.100.1.11.15) object 3. Add portClearCountTable(7.100.3.15) object 4. Add slotNum(7.100.3.2.1.4) object 5. Add mode 'full2500' in speedDuplex object\"",
"REVISION",
[
"literal",
"223230323431323036313230305a22"
],
"DESCRIPTION",
"\"eNOS 1.13.0 1. Add macNotifications(7.101.107) object 2. Add stormControlTable(7.100.3.3) object 3. Add stormControlActionTable(7.100.3.20) object 4. Add bandwidthControlStatus(7.100.3.2.1.7) object 5. Add maxBandwidth(7.100.3.2.1.8) object 6. Add receiveBandwidth(7.100.3.2.1.9) object 7. Add transmitBandwidth(7.100.3.2.1.10) object 8. Add macNotificationMib(7.100.33) object\"",
"REVISION",
[
"literal",
"223230323431313133313230305a22"
],
"DESCRIPTION",
"\"eNOS 1.12.0 1. Add sysWriteConfig(7.100.1.6) object 2. Add switchFlashSizeInBytes(7.100.1.11.14) object 3. Add priDhcp(7.100.13) object\"",
"REVISION",
[
"literal",
"223230323430393137313230305a22"
],
"DESCRIPTION",
"\"eNOS 1.11.0 1. Add portSecurity(7.100.32) object 2. Add priPoeConfig(7.100.26.10) object\"",
"REVISION",
[
"literal",
"223230323430363230313230305a22"
],
"DESCRIPTION",
"\"eNOS 1.9.0 1. Add poeCurrentPower(7.100.26.6) object 2. Add sysPowerStateTable(7.100.1.7) object\"",
"::=",
"{",
"enterprises",
"57206",
"}"
],
"syntax_tree": [
[
"LAST-UPDATED",
"202506181200Z"
],
[
"ORGANIZATION",
"NAG"
],
[
"CONTACT-INFO",
"support@nag.ru"
],
[
"DESCRIPTION",
"MIB module for SNR-S5XXX series switches"
],
[
"Revisions",
[
[
"202506181200Z",
[
"DESCRIPTION",
"eNOS 1.16.0 1. Add isolatePortCfg(7.100.100) object"
]
],
[
"202503121200Z",
[
"DESCRIPTION",
"eNOS 1.15.0 1. Add acl(7.100.10.1) object 2. Add dcscm(7.100.20) object 3. Add loopbackDetecIntervalTime(7.100.3.4.2) object 4. Add loopbackDetecCtrlTable(7.100.3.4.3) object 5. Add loopbackDetecBlockCtrlRecovery(7.100.3.4.20) object 6. Add loopbackDetectEnableTable(7.100.3.4.21) object 7. Add errdisableTimeoutEnable(7.100.3.30) object 8. Add errdisableTimeoutInterval(7.100.3.31) object 9. Add mode 'private-vlan host' in portMode object 10. Add mode 'private-vlan promiscuous' in portMode object 11. Add loopBackDetect-trap(7.101.112) object"
]
],
[
"202502041200Z",
[
"DESCRIPTION",
"eNOS 1.14.0 1. Add switchCPUOneMinuteIdle(7.100.1.11.25) object 2. Add switchFlashOccupiedSizeInBytes(7.100.1.11.15) object 3. Add portClearCountTable(7.100.3.15) object 4. Add slotNum(7.100.3.2.1.4) object 5. Add mode 'full2500' in speedDuplex object"
]
],
[
"202412061200Z",
[
"DESCRIPTION",
"eNOS 1.13.0 1. Add macNotifications(7.101.107) object 2. Add stormControlTable(7.100.3.3) object 3. Add stormControlActionTable(7.100.3.20) object 4. Add bandwidthControlStatus(7.100.3.2.1.7) object 5. Add maxBandwidth(7.100.3.2.1.8) object 6. Add receiveBandwidth(7.100.3.2.1.9) object 7. Add transmitBandwidth(7.100.3.2.1.10) object 8. Add macNotificationMib(7.100.33) object"
]
],
[
"202411131200Z",
[
"DESCRIPTION",
"eNOS 1.12.0 1. Add sysWriteConfig(7.100.1.6) object 2. Add switchFlashSizeInBytes(7.100.1.11.14) object 3. Add priDhcp(7.100.13) object"
]
],
[
"202409171200Z",
[
"DESCRIPTION",
"eNOS 1.11.0 1. Add portSecurity(7.100.32) object 2. Add priPoeConfig(7.100.26.10) object"
]
],
[
"202406201200Z",
[
"DESCRIPTION",
"eNOS 1.9.0 1. Add poeCurrentPower(7.100.26.6) object 2. Add sysPowerStateTable(7.100.1.7) object"
]
]
]
]
]
}Vendor MIB copy from the Observium Community archive.
Module: NAG-MIB
nag MODULE-IDENTITY
LAST-UPDATED "202506181200Z" -- Jun 18, 2025
ORGANIZATION "NAG"
CONTACT-INFO "support@nag.ru"
DESCRIPTION "MIB module for SNR-S5XXX series switches"
REVISION "202506181200Z" -- Jun 18, 2025
DESCRIPTION "eNOS 1.16.0
1. Add isolatePortCfg(7.100.100) object"
REVISION "202503121200Z" -- Mar 12, 2025
DESCRIPTION "eNOS 1.15.0
1. Add acl(7.100.10.1) object
2. Add dcscm(7.100.20) object
3. Add loopbackDetecIntervalTime(7.100.3.4.2) object
4. Add loopbackDetecCtrlTable(7.100.3.4.3) object
5. Add loopbackDetecBlockCtrlRecovery(7.100.3.4.20) object
6. Add loopbackDetectEnableTable(7.100.3.4.21) object
7. Add errdisableTimeoutEnable(7.100.3.30) object
8. Add errdisableTimeoutInterval(7.100.3.31) object
9. Add mode 'private-vlan host' in portMode object
10. Add mode 'private-vlan promiscuous' in portMode object
11. Add loopBackDetect-trap(7.101.112) object"
REVISION "202502041200Z" -- Feb 4, 2025
DESCRIPTION "eNOS 1.14.0
1. Add switchCPUOneMinuteIdle(7.100.1.11.25) object
2. Add switchFlashOccupiedSizeInBytes(7.100.1.11.15) object
3. Add portClearCountTable(7.100.3.15) object
4. Add slotNum(7.100.3.2.1.4) object
5. Add mode 'full2500' in speedDuplex object"
REVISION "202412061200Z" -- Dec 6, 2024
DESCRIPTION "eNOS 1.13.0
1. Add macNotifications(7.101.107) object
2. Add stormControlTable(7.100.3.3) object
3. Add stormControlActionTable(7.100.3.20) object
4. Add bandwidthControlStatus(7.100.3.2.1.7) object
5. Add maxBandwidth(7.100.3.2.1.8) object
6. Add receiveBandwidth(7.100.3.2.1.9) object
7. Add transmitBandwidth(7.100.3.2.1.10) object
8. Add macNotificationMib(7.100.33) object"
REVISION "202411131200Z" -- Nov 13, 2024
DESCRIPTION "eNOS 1.12.0
1. Add sysWriteConfig(7.100.1.6) object
2. Add switchFlashSizeInBytes(7.100.1.11.14) object
3. Add priDhcp(7.100.13) object"
REVISION "202409171200Z" -- Sept 17, 2024
DESCRIPTION "eNOS 1.11.0
1. Add portSecurity(7.100.32) object
2. Add priPoeConfig(7.100.26.10) object"
REVISION "202406201200Z" -- June 20, 2024
DESCRIPTION "eNOS 1.9.0
1. Add poeCurrentPower(7.100.26.6) object
2. Add sysPowerStateTable(7.100.1.7) object"
::= { enterprises 57206 }{'RFC-1215': ['TRAP-TYPE'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'RowStatus', 'TimeStamp', 'TruthValue'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'MODULE-IDENTITY', 'OBJECT-TYPE', 'mib-2', 'Integer32', 'Counter32', 'Counter64', 'Gauge32', 'Unsigned32', 'NOTIFICATION-TYPE', 'IpAddress', 'TimeTicks', 'experimental'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['ifIndex'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP']}Related source files and packages:
Downloaded: 2026-10-24T02:14:26.010162+00:00.
Status in source: unspecified.
{
"contact": "Petr Milenin",
"organization": "NAGTECH LLC",
"email_as_published": "p.milenin&nagtech.ru"
}Downloaded: 2026-10-24T04:19:29.314233+00:00.
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.57206.7 | snr | 3 | 325 |
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.46800 | 46800 | 0 | 0 | Digitoll Information Technology and Servicing Ltd. |
| 1.3.6.1.4.1.46801 | 46801 | 0 | 0 | The Hut Group |
| 1.3.6.1.4.1.46802 | 46802 | 0 | 0 | The Business Clinic Ltd |
| 1.3.6.1.4.1.46803 | 46803 | 0 | 0 | BROCELIA |
| 1.3.6.1.4.1.46804 | 46804 | 0 | 0 | Himnark CJSC |
| 1.3.6.1.4.1.46805 | 46805 | 0 | 0 | Oncology Consultants |
| 1.3.6.1.4.1.46806 | 46806 | 0 | 0 | Mid Florida Hematology Oncology |
| 1.3.6.1.4.1.46807 | 46807 | 0 | 0 | Motiv Telecom Group |
| 1.3.6.1.4.1.46808 | 46808 | 0 | 0 | Fall River School District |
| 1.3.6.1.4.1.46809 | 46809 | 0 | 0 | KB PROMSVYAZ |
| 1.3.6.1.4.1.46810 | 46810 | 0 | 0 | Stockton University |
| 1.3.6.1.4.1.46811 | 46811 | 0 | 0 | L'Imprimerie |
| 1.3.6.1.4.1.46812 | 46812 | 0 | 0 | Konsortium "ICT" Pantai Timur |
| 1.3.6.1.4.1.46813 | 46813 | 0 | 0 | Sunbird Software, Inc. |
| 1.3.6.1.4.1.46814 | 46814 | 0 | 0 | "SC3" Technologies Oü |
| 1.3.6.1.4.1.46815 | 46815 | 0 | 0 | Third Point LLC |
| 1.3.6.1.4.1.46816 | 46816 | 0 | 0 | HELM AG |
| 1.3.6.1.4.1.46817 | 46817 | 0 | 0 | Atam Holdings |
| 1.3.6.1.4.1.46818 | 46818 | 0 | 0 | Systemhaus Scheuschner GmbH |
| 1.3.6.1.4.1.46819 | 46819 | 0 | 0 | Attenda Ltd. |
| 1.3.6.1.4.1.46820 | 46820 | 0 | 0 | Telekom Malaysia Berhad |
| 1.3.6.1.4.1.46821 | 46821 | 0 | 0 | Commandus |
| 1.3.6.1.4.1.46822 | 46822 | 0 | 0 | Zhuhai Kingsoft Office Software Co Ltd |
| 1.3.6.1.4.1.46823 | 46823 | 0 | 0 | Siselectron Technology Ltd |
| 1.3.6.1.4.1.46824 | 46824 | 0 | 0 | Certly, Inc. |
| 1.3.6.1.4.1.46825 | 46825 | 0 | 0 | Loop Technologies Limited |
| 1.3.6.1.4.1.46826 | 46826 | 0 | 0 | OptimalMethods Ltd. |
| 1.3.6.1.4.1.46827 | 46827 | 0 | 0 | Affix Technology Co., Ltd. |
| 1.3.6.1.4.1.46828 | 46828 | 0 | 0 | Sea and Air Technology, S.L. |
| 1.3.6.1.4.1.46829 | 46829 | 0 | 0 | GLOCK Ges.m.b.H. |
| 1.3.6.1.4.1.46830 | 46830 | 0 | 0 | LearnConsult - DI Meitz & Ing. Pock OG |
| 1.3.6.1.4.1.46831 | 46831 | 0 | 0 | GRAUPNER medical solutions GmbH |
| 1.3.6.1.4.1.46832 | 46832 | 0 | 0 | Heylige FRau Latte |
| 1.3.6.1.4.1.46833 | 46833 | 0 | 0 | Synapses Technologies, LLC |
| 1.3.6.1.4.1.46834 | 46834 | 0 | 0 | Martin GmbH für Umwelt- und Energietechnik |
| 1.3.6.1.4.1.46835 | 46835 | 0 | 0 | rf152 |
| 1.3.6.1.4.1.46836 | 46836 | 0 | 0 | Bilfinger GreyLogix GmbH |
| 1.3.6.1.4.1.46837 | 46837 | 0 | 0 | AZD Praha s.r.o. |
| 1.3.6.1.4.1.46838 | 46838 | 0 | 0 | Swaffer Consulting Ltd. |
| 1.3.6.1.4.1.46839 | 46839 | 0 | 0 | Red Electrica de España Sau |
| 1.3.6.1.4.1.46840 | 46840 | 0 | 0 | Christophorus Club e.V. |
| 1.3.6.1.4.1.46841 | 46841 | 0 | 0 | Hwacheon Machinery Europe GmbH |
| 1.3.6.1.4.1.46842 | 46842 | 0 | 0 | Hamburger Software GmbH & Co. KG |
| 1.3.6.1.4.1.46843 | 46843 | 0 | 0 | Newfield Automation Ltd. |
| 1.3.6.1.4.1.46844 | 46844 | 0 | 0 | Dreamtime.net (Thailand) Co., Ltd. |
| 1.3.6.1.4.1.46845 | 46845 | 0 | 0 | Interlink INC |
| 1.3.6.1.4.1.46846 | 46846 | 0 | 0 | FLOPNET |
| 1.3.6.1.4.1.46847 | 46847 | 0 | 0 | VALLEY MEDICAL & SURGICAL CLINIC |
| 1.3.6.1.4.1.46848 | 46848 | 0 | 0 | Lavelle Networks India Private Limited |
| 1.3.6.1.4.1.46849 | 46849 | 0 | 0 | Irving Independent School District |