nag — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
MIB module for SNR-S5XXX series switches
{1 3 6 1 4 1 57206}
MIB module for SNR-S5XXX series switches
NAGTECH LLC
Status in source: unspecified.
Names: nag
{
"smi_kind": "MODULE-IDENTITY",
"definition": [
"nag",
"MODULE-IDENTITY",
"LAST-UPDATED",
[
"literal",
"223230323530363138313230305a22"
],
"ORGANIZATION",
"\"NAG\"",
"CONTACT-INFO",
"\"support@nag.ru\"",
"DESCRIPTION",
"\"MIB module for SNR-S5XXX series switches\"",
"REVISION",
[
"literal",
"223230323530363138313230305a22"
],
"DESCRIPTION",
"\"eNOS 1.16.0 1. Add isolatePortCfg(7.100.100) object\"",
"REVISION",
[
"literal",
"223230323530333132313230305a22"
],
"DESCRIPTION",
"\"eNOS 1.15.0 1. Add acl(7.100.10.1) object 2. Add dcscm(7.100.20) object 3. Add loopbackDetecIntervalTime(7.100.3.4.2) object 4. Add loopbackDetecCtrlTable(7.100.3.4.3) object 5. Add loopbackDetecBlockCtrlRecovery(7.100.3.4.20) object 6. Add loopbackDetectEnableTable(7.100.3.4.21) object 7. Add errdisableTimeoutEnable(7.100.3.30) object 8. Add errdisableTimeoutInterval(7.100.3.31) object 9. Add mode 'private-vlan host' in portMode object 10. Add mode 'private-vlan promiscuous' in portMode object 11. Add loopBackDetect-trap(7.101.112) object\"",
"REVISION",
[
"literal",
"223230323530323034313230305a22"
],
"DESCRIPTION",
"\"eNOS 1.14.0 1. Add switchCPUOneMinuteIdle(7.100.1.11.25) object 2. Add switchFlashOccupiedSizeInBytes(7.100.1.11.15) object 3. Add portClearCountTable(7.100.3.15) object 4. Add slotNum(7.100.3.2.1.4) object 5. Add mode 'full2500' in speedDuplex object\"",
"REVISION",
[
"literal",
"223230323431323036313230305a22"
],
"DESCRIPTION",
"\"eNOS 1.13.0 1. Add macNotifications(7.101.107) object 2. Add stormControlTable(7.100.3.3) object 3. Add stormControlActionTable(7.100.3.20) object 4. Add bandwidthControlStatus(7.100.3.2.1.7) object 5. Add maxBandwidth(7.100.3.2.1.8) object 6. Add receiveBandwidth(7.100.3.2.1.9) object 7. Add transmitBandwidth(7.100.3.2.1.10) object 8. Add macNotificationMib(7.100.33) object\"",
"REVISION",
[
"literal",
"223230323431313133313230305a22"
],
"DESCRIPTION",
"\"eNOS 1.12.0 1. Add sysWriteConfig(7.100.1.6) object 2. Add switchFlashSizeInBytes(7.100.1.11.14) object 3. Add priDhcp(7.100.13) object\"",
"REVISION",
[
"literal",
"223230323430393137313230305a22"
],
"DESCRIPTION",
"\"eNOS 1.11.0 1. Add portSecurity(7.100.32) object 2. Add priPoeConfig(7.100.26.10) object\"",
"REVISION",
[
"literal",
"223230323430363230313230305a22"
],
"DESCRIPTION",
"\"eNOS 1.9.0 1. Add poeCurrentPower(7.100.26.6) object 2. Add sysPowerStateTable(7.100.1.7) object\"",
"::=",
"{",
"enterprises",
"57206",
"}"
],
"syntax_tree": [
[
"LAST-UPDATED",
"202506181200Z"
],
[
"ORGANIZATION",
"NAG"
],
[
"CONTACT-INFO",
"support@nag.ru"
],
[
"DESCRIPTION",
"MIB module for SNR-S5XXX series switches"
],
[
"Revisions",
[
[
"202506181200Z",
[
"DESCRIPTION",
"eNOS 1.16.0 1. Add isolatePortCfg(7.100.100) object"
]
],
[
"202503121200Z",
[
"DESCRIPTION",
"eNOS 1.15.0 1. Add acl(7.100.10.1) object 2. Add dcscm(7.100.20) object 3. Add loopbackDetecIntervalTime(7.100.3.4.2) object 4. Add loopbackDetecCtrlTable(7.100.3.4.3) object 5. Add loopbackDetecBlockCtrlRecovery(7.100.3.4.20) object 6. Add loopbackDetectEnableTable(7.100.3.4.21) object 7. Add errdisableTimeoutEnable(7.100.3.30) object 8. Add errdisableTimeoutInterval(7.100.3.31) object 9. Add mode 'private-vlan host' in portMode object 10. Add mode 'private-vlan promiscuous' in portMode object 11. Add loopBackDetect-trap(7.101.112) object"
]
],
[
"202502041200Z",
[
"DESCRIPTION",
"eNOS 1.14.0 1. Add switchCPUOneMinuteIdle(7.100.1.11.25) object 2. Add switchFlashOccupiedSizeInBytes(7.100.1.11.15) object 3. Add portClearCountTable(7.100.3.15) object 4. Add slotNum(7.100.3.2.1.4) object 5. Add mode 'full2500' in speedDuplex object"
]
],
[
"202412061200Z",
[
"DESCRIPTION",
"eNOS 1.13.0 1. Add macNotifications(7.101.107) object 2. Add stormControlTable(7.100.3.3) object 3. Add stormControlActionTable(7.100.3.20) object 4. Add bandwidthControlStatus(7.100.3.2.1.7) object 5. Add maxBandwidth(7.100.3.2.1.8) object 6. Add receiveBandwidth(7.100.3.2.1.9) object 7. Add transmitBandwidth(7.100.3.2.1.10) object 8. Add macNotificationMib(7.100.33) object"
]
],
[
"202411131200Z",
[
"DESCRIPTION",
"eNOS 1.12.0 1. Add sysWriteConfig(7.100.1.6) object 2. Add switchFlashSizeInBytes(7.100.1.11.14) object 3. Add priDhcp(7.100.13) object"
]
],
[
"202409171200Z",
[
"DESCRIPTION",
"eNOS 1.11.0 1. Add portSecurity(7.100.32) object 2. Add priPoeConfig(7.100.26.10) object"
]
],
[
"202406201200Z",
[
"DESCRIPTION",
"eNOS 1.9.0 1. Add poeCurrentPower(7.100.26.6) object 2. Add sysPowerStateTable(7.100.1.7) object"
]
]
]
]
]
}Vendor MIB copy from the Observium Community archive.
Module: NAG-MIB
nag MODULE-IDENTITY
LAST-UPDATED "202506181200Z" -- Jun 18, 2025
ORGANIZATION "NAG"
CONTACT-INFO "support@nag.ru"
DESCRIPTION "MIB module for SNR-S5XXX series switches"
REVISION "202506181200Z" -- Jun 18, 2025
DESCRIPTION "eNOS 1.16.0
1. Add isolatePortCfg(7.100.100) object"
REVISION "202503121200Z" -- Mar 12, 2025
DESCRIPTION "eNOS 1.15.0
1. Add acl(7.100.10.1) object
2. Add dcscm(7.100.20) object
3. Add loopbackDetecIntervalTime(7.100.3.4.2) object
4. Add loopbackDetecCtrlTable(7.100.3.4.3) object
5. Add loopbackDetecBlockCtrlRecovery(7.100.3.4.20) object
6. Add loopbackDetectEnableTable(7.100.3.4.21) object
7. Add errdisableTimeoutEnable(7.100.3.30) object
8. Add errdisableTimeoutInterval(7.100.3.31) object
9. Add mode 'private-vlan host' in portMode object
10. Add mode 'private-vlan promiscuous' in portMode object
11. Add loopBackDetect-trap(7.101.112) object"
REVISION "202502041200Z" -- Feb 4, 2025
DESCRIPTION "eNOS 1.14.0
1. Add switchCPUOneMinuteIdle(7.100.1.11.25) object
2. Add switchFlashOccupiedSizeInBytes(7.100.1.11.15) object
3. Add portClearCountTable(7.100.3.15) object
4. Add slotNum(7.100.3.2.1.4) object
5. Add mode 'full2500' in speedDuplex object"
REVISION "202412061200Z" -- Dec 6, 2024
DESCRIPTION "eNOS 1.13.0
1. Add macNotifications(7.101.107) object
2. Add stormControlTable(7.100.3.3) object
3. Add stormControlActionTable(7.100.3.20) object
4. Add bandwidthControlStatus(7.100.3.2.1.7) object
5. Add maxBandwidth(7.100.3.2.1.8) object
6. Add receiveBandwidth(7.100.3.2.1.9) object
7. Add transmitBandwidth(7.100.3.2.1.10) object
8. Add macNotificationMib(7.100.33) object"
REVISION "202411131200Z" -- Nov 13, 2024
DESCRIPTION "eNOS 1.12.0
1. Add sysWriteConfig(7.100.1.6) object
2. Add switchFlashSizeInBytes(7.100.1.11.14) object
3. Add priDhcp(7.100.13) object"
REVISION "202409171200Z" -- Sept 17, 2024
DESCRIPTION "eNOS 1.11.0
1. Add portSecurity(7.100.32) object
2. Add priPoeConfig(7.100.26.10) object"
REVISION "202406201200Z" -- June 20, 2024
DESCRIPTION "eNOS 1.9.0
1. Add poeCurrentPower(7.100.26.6) object
2. Add sysPowerStateTable(7.100.1.7) object"
::= { enterprises 57206 }{'RFC-1215': ['TRAP-TYPE'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'RowStatus', 'TimeStamp', 'TruthValue'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'MODULE-IDENTITY', 'OBJECT-TYPE', 'mib-2', 'Integer32', 'Counter32', 'Counter64', 'Gauge32', 'Unsigned32', 'NOTIFICATION-TYPE', 'IpAddress', 'TimeTicks', 'experimental'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['ifIndex'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP']}Related source files and packages:
Downloaded: 2026-10-24T02:14:26.010162+00:00.
Status in source: unspecified.
{
"contact": "Petr Milenin",
"organization": "NAGTECH LLC",
"email_as_published": "p.milenin&nagtech.ru"
}Downloaded: 2026-10-24T04:19:29.314233+00:00.
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.57206.7 | snr | 3 | 325 |
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.48050 | 48050 | 0 | 0 | International Personal Finance |
| 1.3.6.1.4.1.48051 | 48051 | 0 | 0 | Sato America |
| 1.3.6.1.4.1.48052 | 48052 | 0 | 0 | Milpowerinc |
| 1.3.6.1.4.1.48053 | 48053 | 0 | 0 | Mazatal Hotel and Casino |
| 1.3.6.1.4.1.48054 | 48054 | 0 | 0 | SunGard Data Systems |
| 1.3.6.1.4.1.48055 | 48055 | 0 | 0 | sendhybrid GmbH |
| 1.3.6.1.4.1.48056 | 48056 | 0 | 0 | Jeremy Gibbons |
| 1.3.6.1.4.1.48057 | 48057 | 0 | 0 | Kronos Technologies |
| 1.3.6.1.4.1.48058 | 48058 | 0 | 0 | SouthEast Texas Regional Advisory Council |
| 1.3.6.1.4.1.48059 | 48059 | 0 | 0 | Karlsruhe Institute of Technology (KIT) |
| 1.3.6.1.4.1.48060 | 48060 | 0 | 0 | SecureMe2 |
| 1.3.6.1.4.1.48061 | 48061 | 0 | 0 | Byte Expert B.V. |
| 1.3.6.1.4.1.48062 | 48062 | 0 | 0 | Territorial Generation Company 14 |
| 1.3.6.1.4.1.48063 | 48063 | 0 | 0 | Anna Jaques Cancer Center |
| 1.3.6.1.4.1.48064 | 48064 | 0 | 0 | Grupo MSA S.A. |
| 1.3.6.1.4.1.48065 | 48065 | 0 | 0 | Talentnet Corporation |
| 1.3.6.1.4.1.48066 | 48066 | 0 | 0 | Linkforce Engineering |
| 1.3.6.1.4.1.48067 | 48067 | 0 | 0 | UnifyID, Inc. |
| 1.3.6.1.4.1.48068 | 48068 | 0 | 0 | CSE Transtel |
| 1.3.6.1.4.1.48069 | 48069 | 0 | 0 | Demmich IT Service |
| 1.3.6.1.4.1.48070 | 48070 | 0 | 0 | Patrick Lesky |
| 1.3.6.1.4.1.48071 | 48071 | 0 | 0 | Retarus GmbH |
| 1.3.6.1.4.1.48072 | 48072 | 0 | 0 | Optanix |
| 1.3.6.1.4.1.48073 | 48073 | 0 | 0 | Pentest Limited |
| 1.3.6.1.4.1.48074 | 48074 | 0 | 0 | Cube-Tec International GmbH |
| 1.3.6.1.4.1.48075 | 48075 | 0 | 0 | Tennessee Plateau Oncology |
| 1.3.6.1.4.1.48076 | 48076 | 0 | 0 | NexGen Inc |
| 1.3.6.1.4.1.48077 | 48077 | 0 | 0 | State University of Feira de Santana |
| 1.3.6.1.4.1.48078 | 48078 | 0 | 0 | Ventura County Hematology Oncology Specialists |
| 1.3.6.1.4.1.48079 | 48079 | 0 | 0 | NEC Enterprise Communication Technologies |
| 1.3.6.1.4.1.48080 | 48080 | 0 | 0 | Mimetrix Design Group |
| 1.3.6.1.4.1.48081 | 48081 | 0 | 0 | Max Planck Institute for Plant Breeding Research |
| 1.3.6.1.4.1.48082 | 48082 | 0 | 0 | Stromnetz Hamburg GmbH |
| 1.3.6.1.4.1.48083 | 48083 | 0 | 0 | AIRESERVICES |
| 1.3.6.1.4.1.48084 | 48084 | 0 | 0 | Stewart Investors |
| 1.3.6.1.4.1.48085 | 48085 | 0 | 0 | RCCA COMMUNITY HEMATOLOGY ONOCOLGY |
| 1.3.6.1.4.1.48086 | 48086 | 0 | 0 | Helicon Opleidingen |
| 1.3.6.1.4.1.48087 | 48087 | 0 | 0 | Troup County School System |
| 1.3.6.1.4.1.48088 | 48088 | 0 | 0 | Instituto Superior de Economia e Gestão |
| 1.3.6.1.4.1.48089 | 48089 | 0 | 0 | Rådgivende Ingeniør Per Dypvik AS |
| 1.3.6.1.4.1.48090 | 48090 | 0 | 0 | Nord/LB Luxembourg S.A. Covered Bond Bank |
| 1.3.6.1.4.1.48091 | 48091 | 0 | 0 | Sicss Society |
| 1.3.6.1.4.1.48092 | 48092 | 0 | 0 | qi2 |
| 1.3.6.1.4.1.48093 | 48093 | 0 | 0 | Aptomar AS |
| 1.3.6.1.4.1.48094 | 48094 | 0 | 0 | White Star Petroleum |
| 1.3.6.1.4.1.48095 | 48095 | 0 | 0 | Stadler Pankow GmbH |
| 1.3.6.1.4.1.48096 | 48096 | 0 | 0 | jedernet GmbH |
| 1.3.6.1.4.1.48097 | 48097 | 0 | 0 | RAYAPHONE |
| 1.3.6.1.4.1.48098 | 48098 | 0 | 0 | EBPI BV |
| 1.3.6.1.4.1.48099 | 48099 | 0 | 0 | Redgate Software |