Description 1
The parameter value divided by 100 equals the actual value (Unit: Dbm)
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.5875.800.3.9.3.7.1.2
The parameter value divided by 100 equals the actual value (Unit: Dbm)
Identification
{1 3 6 1 4 1 5875 800 3 9 3 7 1 2}
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition. The index encoding is not inferred here.
Published row index: ponIndex, onuNoRxOpticalPower.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.5875.800.3.9.3.7.1.2
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Available source records contain 2 distinct definitions; some records may not include a definition.
oltPonRxOpticalPower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The parameter value divided by 100 equals the actual value (Unit: Dbm)"
::= { oltPonRxOpticalPowerEntry 2 }oltPonRxOpticalPower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Description"
::= { oltPonRxOpticalPowerEntry 2 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Description 1
The parameter value divided by 100 equals the actual value (Unit: Dbm)
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Description 2
Description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: oltPonRxOpticalPower
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"oltPonRxOpticalPower",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"The parameter value divided by 100 equals the actual value (Unit: Dbm)\"",
"::=",
"{",
"oltPonRxOpticalPowerEntry",
"2",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The parameter value divided by 100 equals the actual value (Unit: Dbm)"
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: GEPON-OLT-COMMON-MIB
See published definition above
{'IF-MIB': ['ifIndex'], 'SNMPv2-TC': ['MacAddress', 'RowStatus', 'TruthValue', 'TimeStamp', 'DateAndTime', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['enterprises', 'TimeTicks', 'IpAddress', 'Integer32', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'OBJECT-TYPE', 'MODULE-IDENTITY'], 'RFC1213-MIB': ['snmp'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE']}Related source files and packages:
Status in source: current.
Names: oltPonRxOpticalPower
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"oltPonRxOpticalPower",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"Description\"",
"::=",
"{",
"oltPonRxOpticalPowerEntry",
"2",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Description"
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: GEPON-OLT-COMMON-MIB
See published definition above
{'IF-MIB': ['ifIndex'], 'SNMPv2-TC': ['MacAddress', 'RowStatus', 'TruthValue', 'TEXTUAL-CONVENTION', 'DateAndTime'], 'SNMPv2-SMI': ['enterprises', 'IpAddress', 'Integer32', 'Unsigned32', 'OBJECT-TYPE']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.5875.800.3.9.3.7.1.1 | onuNoRxOpticalPower | 0 | 0 |