This represents the new priority of VRID
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Netdisco MIB archive copies
OID reference
1.3.6.1.4.1.5951.4.1.10.2.44
This represents the new priority of VRID
Identification
{1 3 6 1 4 1 5951 4 1 10 2 44}
A counter is cumulative. To estimate a rate, subtract two readings and divide by the elapsed time; use the units stated in the MIB.
Counter values can wrap or reset. A decrease alone does not distinguish a wrap from a reset, and multiple wraps between readings cannot be recovered reliably. Check the device's discontinuity indicators when available.
Published counter width: 32 bits. SMIv2: Counter32 · Counter64
At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.
A query example is omitted because the source variants do not establish compatible read access.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
newVridPriority OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This represents the new priority of VRID"
::= { snmpTrapVarBindOidsGroup 44 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
This represents the new priority of VRID
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Netdisco MIB archive copies
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: newVridPriority
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"newVridPriority",
"OBJECT-TYPE",
"SYNTAX",
"Counter32",
"MAX-ACCESS",
"accessible-for-notify",
"STATUS",
"current",
"DESCRIPTION",
"\"This represents the new priority of VRID\"",
"::=",
"{",
"snmpTrapVarBindOidsGroup",
"44",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Counter32"
],
null,
[
"MaxAccessPart",
"accessible-for-notify"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This represents the new priority of VRID"
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: NS-ROOT-MIB
See published definition above
{'IPV6-TC': ['Ipv6Address'], 'SNMPv2-SMI': ['Counter32', 'Gauge32', 'Integer32', 'IpAddress', 'NOTIFICATION-TYPE', 'OBJECT-TYPE', 'TimeTicks', 'enterprises', 'MODULE-IDENTITY', 'OBJECT-IDENTITY'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress']}Related source files and packages:
Vendor MIB copy from the Observium Community archive.
Module: NS-ROOT-MIB
{'IPV6-TC': ['Ipv6Address'], 'SNMPv2-SMI': ['Counter32', 'Gauge32', 'Integer32', 'IpAddress', 'NOTIFICATION-TYPE', 'OBJECT-TYPE', 'TimeTicks', 'enterprises', 'MODULE-IDENTITY', 'OBJECT-IDENTITY'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress']}Related source files and packages:
Vendor MIB copy from the Netdisco archive.
Module: NS-ROOT-MIB
{'IPV6-TC': ['Ipv6Address'], 'SNMPv2-SMI': ['Counter32', 'Gauge32', 'Integer32', 'IpAddress', 'NOTIFICATION-TYPE', 'OBJECT-TYPE', 'TimeTicks', 'enterprises', 'MODULE-IDENTITY', 'OBJECT-IDENTITY'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.5951.4.1.10.2.1 | alarmHighThreshold | 1 | 1 | alarmHighthreshold |
| 1.3.6.1.4.1.5951.4.1.10.2.2 | alarmNormalThreshold | 1 | 1 | This is the normal threshold configured for this alarm which triggers the return-to-normal alarm. |
| 1.3.6.1.4.1.5951.4.1.10.2.3 | entityName | 1 | 1 | This represents the name of the entity whose state has changed. |
| 1.3.6.1.4.1.5951.4.1.10.2.4 | nsUserName | 1 | 1 | This represents the name of the system user. |
| 1.3.6.1.4.1.5951.4.1.10.2.5 | configurationCmd | 1 | 1 | This represents the configuartion command that was issued. |
| 1.3.6.1.4.1.5951.4.1.10.2.6 | authorizationStatus | 1 | 1 | This represents the authorization status for an attempted configuration change. |
| 1.3.6.1.4.1.5951.4.1.10.2.7 | commandExecutionStatus | 1 | 1 | This represents the command execution status for the attempted configuration change. |
| 1.3.6.1.4.1.5951.4.1.10.2.8 | unackSynCount | 1 | 1 | The number of un-acknowledged SYNs NetScaler has received in the past synFlood time-interval. |
| 1.3.6.1.4.1.5951.4.1.10.2.9 | alarmLowThreshold | 1 | 1 | This is the low threshold value configured for this alarm. When this threshold is crossed an SNMP alarm is generated. |
| 1.3.6.1.4.1.5951.4.1.10.2.10 | alarmProbeFailedErrorString | 0 | 0 | |
| 1.3.6.1.4.1.5951.4.1.10.2.11 | alarmVipRhiIpAddr | 0 | 0 | |
| 1.3.6.1.4.1.5951.4.1.10.2.12 | alarmVipRhiState | 0 | 0 | |
| 1.3.6.1.4.1.5951.4.1.10.2.13 | alarmRateLmtThresholdExceeded | 0 | 0 | |
| 1.3.6.1.4.1.5951.4.1.10.2.14 | ipAddressGathered | 0 | 0 | |
| 1.3.6.1.4.1.5951.4.1.10.2.15 | stringComputed | 0 | 0 | |
| 1.3.6.1.4.1.5951.4.1.10.2.16 | alarmEntityCurState | 0 | 0 | |
| 1.3.6.1.4.1.5951.4.1.10.2.17 | sysHealthPowerSupplyStatus | 0 | 0 | |
| 1.3.6.1.4.1.5951.4.1.10.2.18 | alarmCurrentValue | 0 | 0 | |
| 1.3.6.1.4.1.5951.4.1.10.2.19 | alarmVipRhiInetAddressType | 0 | 0 | |
| 1.3.6.1.4.1.5951.4.1.10.2.20 | alarmVipRhiInetAddress | 0 | 0 | |
| 1.3.6.1.4.1.5951.4.1.10.2.21 | alarmVsvrOldName | 0 | 0 | |
| 1.3.6.1.4.1.5951.4.1.10.2.22 | alarmVsvrNewName | 0 | 0 | |
| 1.3.6.1.4.1.5951.4.1.10.2.23 | nsClientIPAddr | 0 | 0 | |
| 1.3.6.1.4.1.5951.4.1.10.2.24 | ipConflictAddr | 0 | 0 | |
| 1.3.6.1.4.1.5951.4.1.10.2.25 | appfwLogMsg | 0 | 0 | |
| 1.3.6.1.4.1.5951.4.1.10.2.26 | dnskeyName | 0 | 0 | |
| 1.3.6.1.4.1.5951.4.1.10.2.27 | dnskeyTimeToExpire | 0 | 0 | |
| 1.3.6.1.4.1.5951.4.1.10.2.28 | dnskeyUnitsOfExpiry | 0 | 0 | |
| 1.3.6.1.4.1.5951.4.1.10.2.29 | entityNewName | 0 | 0 | |
| 1.3.6.1.4.1.5951.4.1.10.2.30 | entityOldName | 0 | 0 | |
| 1.3.6.1.4.1.5951.4.1.10.2.31 | platformRateLimitPacketDropCount | 0 | 0 | |
| 1.3.6.1.4.1.5951.4.1.10.2.32 | haLicenseMatchState | 0 | 0 | |
| 1.3.6.1.4.1.5951.4.1.10.2.33 | sslCardStatusMsg | 0 | 0 | |
| 1.3.6.1.4.1.5951.4.1.10.2.34 | callHomeUploadEventStatusMsg | 0 | 0 | |
| 1.3.6.1.4.1.5951.4.1.10.2.35 | oldCCOIP | 0 | 0 | |
| 1.3.6.1.4.1.5951.4.1.10.2.36 | newCCOIP | 0 | 0 | |
| 1.3.6.1.4.1.5951.4.1.10.2.37 | oldOVS | 0 | 0 | |
| 1.3.6.1.4.1.5951.4.1.10.2.38 | newOVS | 0 | 0 | |
| 1.3.6.1.4.1.5951.4.1.10.2.39 | qosdVersion | 0 | 0 | |
| 1.3.6.1.4.1.5951.4.1.10.2.40 | brVersion | 0 | 0 | |
| 1.3.6.1.4.1.5951.4.1.10.2.41 | sslChipName | 0 | 0 | |
| 1.3.6.1.4.1.5951.4.1.10.2.42 | vrid | 0 | 0 | |
| 1.3.6.1.4.1.5951.4.1.10.2.43 | vridBoundVIP | 0 | 0 | |
| 1.3.6.1.4.1.5951.4.1.10.2.45 | oldVridPriority | 0 | 0 | |
| 1.3.6.1.4.1.5951.4.1.10.2.46 | effectiveVridPriority | 0 | 0 | |
| 1.3.6.1.4.1.5951.4.1.10.2.47 | dstip | 0 | 0 | |
| 1.3.6.1.4.1.5951.4.1.10.2.48 | platformLicensedThroughput | 0 | 0 | |
| 1.3.6.1.4.1.5951.4.1.10.2.49 | platformLicensedPPS | 0 | 0 | |
| 1.3.6.1.4.1.5951.4.1.10.2.50 | commandFailureReason | 0 | 0 | |
| 1.3.6.1.4.1.5951.4.1.10.2.51 | nsIPAddressType | 0 | 0 |