setMsiEntry

1.3.6.1.4.1.601.3.1.1.3.18.4.1

Description

Input alarm attributes and settings. setMsiChassis Identifies which chassis is being addressed. setMsiSlot Identifies which slot position is being addressed. setMsiPort Identifies which port position is being addressed. setMsiMtieStd Set the input port setting of the MTIE limits to predefined values. setMsiMtie10EL1 S…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.601.3.1.1.3.18.4 (setAlmThSineInpTable)
Node code
1
Node name
setMsiEntry
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.601.3.1.1.3.18.4.1
URN notation
urn:oid:1.3.6.1.4.1.601.3.1.1.3.18.4.1
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 601 3 1 1 3 18 4 1}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) datum(601) austron(3) products(1) ssu2000(1) msetup(3) setupSineInp(18) setAlmThSineInpTable(4) setMsiEntry(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) datum(601) austron(3) products(1) ssu2000(1) msetup(3) setupSineInp(18) setAlmThSineInpTable(4) setMsiEntry(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) datum(601) austron(3) products(1) ssu2000(1) msetup(3) setupSineInp(18) setAlmThSineInpTable(4) setMsiEntry(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) datum(601) austron(3) products(1) ssu2000(1) msetup(3) setupSineInp(18) setAlmThSineInpTable(4) setMsiEntry(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) datum(601) austron(3) products(1) ssu2000(1) msetup(3) setupSineInp(18) setAlmThSineInpTable(4) setMsiEntry(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) datum(601) austron(3) products(1) ssu2000(1) msetup(3) setupSineInp(18) setAlmThSineInpTable(4) setMsiEntry(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) datum(601) austron(3) products(1) ssu2000(1) msetup(3) setupSineInp(18) setAlmThSineInpTable(4) setMsiEntry(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) datum(601) austron(3) products(1) ssu2000(1) msetup(3) setupSineInp(18) setAlmThSineInpTable(4) setMsiEntry(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) datum(601) austron(3) products(1) ssu2000(1) msetup(3) setupSineInp(18) setAlmThSineInpTable(4) setMsiEntry(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) datum(601) austron(3) products(1) ssu2000(1) msetup(3) setupSineInp(18) setAlmThSineInpTable(4) setMsiEntry(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) datum(601) austron(3) products(1) ssu2000(1) msetup(3) setupSineInp(18) setAlmThSineInpTable(4) setMsiEntry(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) datum(601) austron(3) products(1) ssu2000(1) msetup(3) setupSineInp(18) setAlmThSineInpTable(4) setMsiEntry(1)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) datum(601) austron(3) products(1) ssu2000(1) msetup(3) setupSineInp(18) setAlmThSineInpTable(4) setMsiEntry(1)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) datum(601) austron(3) products(1) ssu2000(1) msetup(3) setupSineInp(18) setAlmThSineInpTable(4) setMsiEntry(1)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) datum(601) austron(3) products(1) ssu2000(1) msetup(3) setupSineInp(18) setAlmThSineInpTable(4) setMsiEntry(1)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) datum(601) austron(3) products(1) ssu2000(1) msetup(3) setupSineInp(18) setAlmThSineInpTable(4) setMsiEntry(1)}
OID-IRI notation
  • /1/3/6/1/4/1/601/3/1/1/3/18/4/1
  • /ISO/Identified-Organization/6/1/4/1/601/3/1/1/3/18/4/1
  • /ISO/3/6/1/4/1/601/3/1/1/3/18/4/1
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/601/austron/products/ssu2000/msetup/setupSineInp/setAlmThSineInpTable/setMsiEntry
  • /iso/identified-organization/dod/internet/private/enterprise/datum/austron/products/ssu2000/msetup/setupSineInp/setAlmThSineInpTable/setMsiEntry
  • /iso/identified-organization/dod/internet/private/enterprises/601/austron/products/ssu2000/msetup/setupSineInp/setAlmThSineInpTable/setMsiEntry
  • /iso/identified-organization/dod/internet/private/enterprises/datum/austron/products/ssu2000/msetup/setupSineInp/setAlmThSineInpTable/setMsiEntry
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/601/austron/products/ssu2000/msetup/setupSineInp/setAlmThSineInpTable/setMsiEntry
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/datum/austron/products/ssu2000/msetup/setupSineInp/setAlmThSineInpTable/setMsiEntry
  • /iso/identified-organization/dod/internet/private/vendor-objects/601/austron/products/ssu2000/msetup/setupSineInp/setAlmThSineInpTable/setMsiEntry
  • /iso/identified-organization/dod/internet/private/vendor-objects/datum/austron/products/ssu2000/msetup/setupSineInp/setAlmThSineInpTable/setMsiEntry
  • /iso/org/dod/internet/private/enterprise/601/austron/products/ssu2000/msetup/setupSineInp/setAlmThSineInpTable/setMsiEntry
  • /iso/org/dod/internet/private/enterprise/datum/austron/products/ssu2000/msetup/setupSineInp/setAlmThSineInpTable/setMsiEntry
  • /iso/org/dod/internet/private/enterprises/601/austron/products/ssu2000/msetup/setupSineInp/setAlmThSineInpTable/setMsiEntry
  • /iso/org/dod/internet/private/enterprises/datum/austron/products/ssu2000/msetup/setupSineInp/setAlmThSineInpTable/setMsiEntry
  • /iso/org/dod/internet/private/ldap-enterprise/601/austron/products/ssu2000/msetup/setupSineInp/setAlmThSineInpTable/setMsiEntry
  • /iso/org/dod/internet/private/ldap-enterprise/datum/austron/products/ssu2000/msetup/setupSineInp/setAlmThSineInpTable/setMsiEntry
  • /iso/org/dod/internet/private/vendor-objects/601/austron/products/ssu2000/msetup/setupSineInp/setAlmThSineInpTable/setMsiEntry
  • /iso/org/dod/internet/private/vendor-objects/datum/austron/products/ssu2000/msetup/setupSineInp/setAlmThSineInpTable/setMsiEntry
  • Additional combinations skipped.

SNMP properties

Value type
SetMsiEntry
Maximum access defined by MIB
not-accessible
Status in MIB
current

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

The displayed source records contain one distinct definition. Compare its source records.

setMsiEntry OBJECT-TYPE
    SYNTAX  SetMsiEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
    "Input alarm attributes and settings.
    setMsiChassis
        Identifies which chassis is being addressed. 
    setMsiSlot
        Identifies which slot position is being addressed. 
    setMsiPort
        Identifies which port position is being addressed. 
    setMsiMtieStd
        Set the input port setting of the MTIE limits to predefined values.
    setMsiMtie10EL1
        Set the input port MTIE 10 seconds error threshold for the first limit setting.
    setMsiMtie10EL2
        Set the input port MTIE 10 seconds error threshold for the second limit setting.
    setMsiMtie10CL1
        Set the input port MTIE 10 seconds clear threshold for the first limit setting.
    setMsiMtie10CL2
        Set the input port MTIE 10 seconds clear threshold for the second limit setting.
    setMsiMtie100EL1
        Set the input port MTIE 100 seconds error threshold for the first limit setting.
    setMsiMtie100EL2
        Set the input port MTIE 100 seconds error threshold for the second limit setting.
    setMsiMtie100CL1
        Set the input port MTIE 100 seconds clear threshold for the first limit setting.
    setMsiMtie100CL2
        Set the input port MTIE 100 seconds clear threshold for the second limit setting.
    setMsiMtie1000EL1
        Set the input port MTIE 1000 seconds error threshold for the first limit setting.
    setMsiMtie1000EL2
        Set the input port MTIE 1000 seconds error threshold for the second limit setting.
    setMsiMtie1000CL1
        Set the input port MTIE 1000 seconds clear threshold for the first limit setting.
    setMsiMtie1000CL2
        Set the input port MTIE 1000 seconds clear threshold for the second limit setting.
    setMsiMtie10000EL1
        Set the input port MTIE 10000 seconds error threshold for the first limit setting.
    setMsiMtie10000EL2
        Set the input port MTIE 10000 seconds error threshold for the second limit setting.
    setMsiMtie10000CL1
        Set the input port MTIE 10000 seconds clear threshold for the first limit setting.
    setMsiMtie10000CL2
        Set the input port MTIE 10000 seconds clear threshold for the second limit setting.
    setMsiMtie100000EL1
        Set the input port MTIE 100000 seconds error threshold for the first limit setting.
    setMsiMtie100000EL2
        Set the input port MTIE 100000 seconds error threshold for the second limit setting.
    setMsiMtie100000CL1
        Set the input port MTIE 100000 seconds clear threshold for the first limit setting.
    setMsiMtie100000CL2
        Set the input port MTIE 100000 seconds clear threshold for the second limit setting.
    setMsiFreqAErrLmt
        Set the input port frequency error threshold for clock A.
    setMsiFreqAClrLmt
        Set the input port frequency clear threshold for clock A.
    setMsiFreqATau
        Set the Time constant (tau), in seconds, used for the calculation of the Average Frequency versus clock A.
    setMsiFreqBErrLmt
        Set the input port frequency error threshold for clock B.
    setMsiFreqBClrLmt
        Set the input port frequency clear threshold for clock B.
    setMsiFreqBTau
        Set the Time constant (tau), in seconds, used for the calculation of the Average Frequency versus clock B.
    "
    INDEX   { setMsiChassis, setMsiSlot, setMsiPort }
    ::= { setAlmThSineInpTable 1 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Input alarm attributes and settings. setMsiChassis Identifies which chassis is being addressed. setMsiSlot Identifies which slot position is being addressed. setMsiPort Identifies which port position is being addressed. setMsiMtieStd Set the input port setting of the MTIE limits to predefined values. setMsiMtie10EL1 Set the input port MTIE 10 seconds error threshold for the first limit setting. setMsiMtie10EL2 Set the input port MTIE 10 seconds error threshold for the second limit setting. setMsiMtie10CL1 Set the input port MTIE 10 seconds clear threshold for the first limit setting. setMsiMtie10CL2 Set the input port MTIE 10 seconds clear threshold for the second limit setting. setMsiMtie100EL1 Set the input port MTIE 100 seconds error threshold for the first limit setting. setMsiMtie100EL2 Set the input port MTIE 100 seconds error threshold for the second limit setting. setMsiMtie100CL1 Set the input port MTIE 100 seconds clear threshold for the first limit setting. setMsiMtie100CL2 Set the input port MTIE 100 seconds clear threshold for the second limit setting. setMsiMtie1000EL1 Set the input port MTIE 1000 seconds error threshold for the first limit setting. setMsiMtie1000EL2 Set the input port MTIE 1000 seconds error threshold for the second limit setting. setMsiMtie1000CL1 Set the input port MTIE 1000 seconds clear threshold for the first limit setting. setMsiMtie1000CL2 Set the input port MTIE 1000 seconds clear threshold for the second limit setting. setMsiMtie10000EL1 Set the input port MTIE 10000 seconds error threshold for the first limit setting. setMsiMtie10000EL2 Set the input port MTIE 10000 seconds error threshold for the second limit setting. setMsiMtie10000CL1 Set the input port MTIE 10000 seconds clear threshold for the first limit setting. setMsiMtie10000CL2 Set the input port MTIE 10000 seconds clear threshold for the second limit setting. setMsiMtie100000EL1 Set the input port MTIE 100000 seconds error threshold for the first limit setting. setMsiMtie100000EL2 Set the input port MTIE 100000 seconds error threshold for the second limit setting. setMsiMtie100000CL1 Set the input port MTIE 100000 seconds clear threshold for the first limit setting. setMsiMtie100000CL2 Set the input port MTIE 100000 seconds clear threshold for the second limit setting. setMsiFreqAErrLmt Set the input port frequency error threshold for clock A. setMsiFreqAClrLmt Set the input port frequency clear threshold for clock A. setMsiFreqATau Set the Time constant (tau), in seconds, used for the calculation of the Average Frequency versus clock A. setMsiFreqBErrLmt Set the input port frequency error threshold for clock B. setMsiFreqBClrLmt Set the input port frequency clear threshold for clock B. setMsiFreqBTau Set the Time constant (tau), in seconds, used for the calculation of the Average Frequency versus clock B.

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 1

setMsiEntry · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: setMsiEntry

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "setMsiEntry",
    "OBJECT-TYPE",
    "SYNTAX",
    "SetMsiEntry",
    "MAX-ACCESS",
    "not-accessible",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Input alarm attributes and settings. setMsiChassis Identifies which chassis is being addressed. setMsiSlot Identifies which slot position is being addressed. setMsiPort Identifies which port position is being addressed. setMsiMtieStd Set the input port setting of the MTIE limits to predefined values. setMsiMtie10EL1 Set the input port MTIE 10 seconds error threshold for the first limit setting. setMsiMtie10EL2 Set the input port MTIE 10 seconds error threshold for the second limit setting. setMsiMtie10CL1 Set the input port MTIE 10 seconds clear threshold for the first limit setting. setMsiMtie10CL2 Set the input port MTIE 10 seconds clear threshold for the second limit setting. setMsiMtie100EL1 Set the input port MTIE 100 seconds error threshold for the first limit setting. setMsiMtie100EL2 Set the input port MTIE 100 seconds error threshold for the second limit setting. setMsiMtie100CL1 Set the input port MTIE 100 seconds clear threshold for the first limit setting. setMsiMtie100CL2 Set the input port MTIE 100 seconds clear threshold for the second limit setting. setMsiMtie1000EL1 Set the input port MTIE 1000 seconds error threshold for the first limit setting. setMsiMtie1000EL2 Set the input port MTIE 1000 seconds error threshold for the second limit setting. setMsiMtie1000CL1 Set the input port MTIE 1000 seconds clear threshold for the first limit setting. setMsiMtie1000CL2 Set the input port MTIE 1000 seconds clear threshold for the second limit setting. setMsiMtie10000EL1 Set the input port MTIE 10000 seconds error threshold for the first limit setting. setMsiMtie10000EL2 Set the input port MTIE 10000 seconds error threshold for the second limit setting. setMsiMtie10000CL1 Set the input port MTIE 10000 seconds clear threshold for the first limit setting. setMsiMtie10000CL2 Set the input port MTIE 10000 seconds clear threshold for the second limit setting. setMsiMtie100000EL1 Set the input port MTIE 100000 seconds error threshold for the first limit setting. setMsiMtie100000EL2 Set the input port MTIE 100000 seconds error threshold for the second limit setting. setMsiMtie100000CL1 Set the input port MTIE 100000 seconds clear threshold for the first limit setting. setMsiMtie100000CL2 Set the input port MTIE 100000 seconds clear threshold for the second limit setting. setMsiFreqAErrLmt Set the input port frequency error threshold for clock A. setMsiFreqAClrLmt Set the input port frequency clear threshold for clock A. setMsiFreqATau Set the Time constant (tau), in seconds, used for the calculation of the Average Frequency versus clock A. setMsiFreqBErrLmt Set the input port frequency error threshold for clock B. setMsiFreqBClrLmt Set the input port frequency clear threshold for clock B. setMsiFreqBTau Set the Time constant (tau), in seconds, used for the calculation of the Average Frequency versus clock B. \"",
    "INDEX",
    "{",
    "setMsiChassis",
    ",",
    "setMsiSlot",
    ",",
    "setMsiPort",
    "}",
    "::=",
    "{",
    "setAlmThSineInpTable",
    "1",
    "}"
  ],
  "syntax_tree": [
    [
      "row",
      "SetMsiEntry"
    ],
    null,
    [
      "MaxAccessPart",
      "not-accessible"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Input alarm attributes and settings. setMsiChassis Identifies which chassis is being addressed. setMsiSlot Identifies which slot position is being addressed. setMsiPort Identifies which port position is being addressed. setMsiMtieStd Set the input port setting of the MTIE limits to predefined values. setMsiMtie10EL1 Set the input port MTIE 10 seconds error threshold for the first limit setting. setMsiMtie10EL2 Set the input port MTIE 10 seconds error threshold for the second limit setting. setMsiMtie10CL1 Set the input port MTIE 10 seconds clear threshold for the first limit setting. setMsiMtie10CL2 Set the input port MTIE 10 seconds clear threshold for the second limit setting. setMsiMtie100EL1 Set the input port MTIE 100 seconds error threshold for the first limit setting. setMsiMtie100EL2 Set the input port MTIE 100 seconds error threshold for the second limit setting. setMsiMtie100CL1 Set the input port MTIE 100 seconds clear threshold for the first limit setting. setMsiMtie100CL2 Set the input port MTIE 100 seconds clear threshold for the second limit setting. setMsiMtie1000EL1 Set the input port MTIE 1000 seconds error threshold for the first limit setting. setMsiMtie1000EL2 Set the input port MTIE 1000 seconds error threshold for the second limit setting. setMsiMtie1000CL1 Set the input port MTIE 1000 seconds clear threshold for the first limit setting. setMsiMtie1000CL2 Set the input port MTIE 1000 seconds clear threshold for the second limit setting. setMsiMtie10000EL1 Set the input port MTIE 10000 seconds error threshold for the first limit setting. setMsiMtie10000EL2 Set the input port MTIE 10000 seconds error threshold for the second limit setting. setMsiMtie10000CL1 Set the input port MTIE 10000 seconds clear threshold for the first limit setting. setMsiMtie10000CL2 Set the input port MTIE 10000 seconds clear threshold for the second limit setting. setMsiMtie100000EL1 Set the input port MTIE 100000 seconds error threshold for the first limit setting. setMsiMtie100000EL2 Set the input port MTIE 100000 seconds error threshold for the second limit setting. setMsiMtie100000CL1 Set the input port MTIE 100000 seconds clear threshold for the first limit setting. setMsiMtie100000CL2 Set the input port MTIE 100000 seconds clear threshold for the second limit setting. setMsiFreqAErrLmt Set the input port frequency error threshold for clock A. setMsiFreqAClrLmt Set the input port frequency clear threshold for clock A. setMsiFreqATau Set the Time constant (tau), in seconds, used for the calculation of the Average Frequency versus clock A. setMsiFreqBErrLmt Set the input port frequency error threshold for clock B. setMsiFreqBClrLmt Set the input port frequency clear threshold for clock B. setMsiFreqBTau Set the Time constant (tau), in seconds, used for the calculation of the Average Frequency versus clock B."
    ],
    null,
    null,
    [
      "INDEX",
      [
        [
          0,
          "setMsiChassis"
        ],
        [
          0,
          "setMsiSlot"
        ],
        [
          0,
          "setMsiPort"
        ]
      ]
    ],
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.601)

Fontes Joe

Direct children (30)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.601.3.1.1.3.18.4.1.1 setMsiChassis00
1.3.6.1.4.1.601.3.1.1.3.18.4.1.2 setMsiSlot00
1.3.6.1.4.1.601.3.1.1.3.18.4.1.3 setMsiPort00
1.3.6.1.4.1.601.3.1.1.3.18.4.1.4 setMsiMtieStd00
1.3.6.1.4.1.601.3.1.1.3.18.4.1.5 setMsiMtie10EL100
1.3.6.1.4.1.601.3.1.1.3.18.4.1.6 setMsiMtie10EL200
1.3.6.1.4.1.601.3.1.1.3.18.4.1.7 setMsiMtie10CL100
1.3.6.1.4.1.601.3.1.1.3.18.4.1.8 setMsiMtie10CL200
1.3.6.1.4.1.601.3.1.1.3.18.4.1.9 setMsiMtie100EL100
1.3.6.1.4.1.601.3.1.1.3.18.4.1.10 setMsiMtie100EL200
1.3.6.1.4.1.601.3.1.1.3.18.4.1.11 setMsiMtie100CL100
1.3.6.1.4.1.601.3.1.1.3.18.4.1.12 setMsiMtie100CL200
1.3.6.1.4.1.601.3.1.1.3.18.4.1.13 setMsiMtie1000EL100
1.3.6.1.4.1.601.3.1.1.3.18.4.1.14 setMsiMtie1000EL200
1.3.6.1.4.1.601.3.1.1.3.18.4.1.15 setMsiMtie1000CL100
1.3.6.1.4.1.601.3.1.1.3.18.4.1.16 setMsiMtie1000CL200
1.3.6.1.4.1.601.3.1.1.3.18.4.1.17 setMsiMtie10000EL100
1.3.6.1.4.1.601.3.1.1.3.18.4.1.18 setMsiMtie10000EL200
1.3.6.1.4.1.601.3.1.1.3.18.4.1.19 setMsiMtie10000CL100
1.3.6.1.4.1.601.3.1.1.3.18.4.1.20 setMsiMtie10000CL200
1.3.6.1.4.1.601.3.1.1.3.18.4.1.21 setMsiMtie100000EL100
1.3.6.1.4.1.601.3.1.1.3.18.4.1.22 setMsiMtie100000EL200
1.3.6.1.4.1.601.3.1.1.3.18.4.1.23 setMsiMtie100000CL100
1.3.6.1.4.1.601.3.1.1.3.18.4.1.24 setMsiMtie100000CL200
1.3.6.1.4.1.601.3.1.1.3.18.4.1.25 setMsiFreqAErrLmt00
1.3.6.1.4.1.601.3.1.1.3.18.4.1.26 setMsiFreqAClrLmt00
1.3.6.1.4.1.601.3.1.1.3.18.4.1.27 setMsiFreqATau00
1.3.6.1.4.1.601.3.1.1.3.18.4.1.28 setMsiFreqBErrLmt00
1.3.6.1.4.1.601.3.1.1.3.18.4.1.29 setMsiFreqBClrLmt00
1.3.6.1.4.1.601.3.1.1.3.18.4.1.30 setMsiFreqBTau00