OID reference

refInp

1.3.6.1.4.1.601.3.1.1.7.2

Description

Report/Set the input reference port. The format is defined as xAy-z. where x is the chassis number: in this case is 1, A is the constant letter 'A', and is chassis/slot sepearator. y is the slot number: (range is 3 to 11) - is the constant letter '-', and is slot/port sepearator z is the port number (1 to 3). For exam…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.601.3.1.1.7 (ref)
Node code
2
Node name
refInp
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.601.3.1.1.7.2
URN notation
urn:oid:1.3.6.1.4.1.601.3.1.1.7.2
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 601 3 1 1 7 2}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) datum(601) austron(3) products(1) ssu2000(1) ref(7) refInp(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) datum(601) austron(3) products(1) ssu2000(1) ref(7) refInp(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) datum(601) austron(3) products(1) ssu2000(1) ref(7) refInp(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) datum(601) austron(3) products(1) ssu2000(1) ref(7) refInp(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) datum(601) austron(3) products(1) ssu2000(1) ref(7) refInp(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) datum(601) austron(3) products(1) ssu2000(1) ref(7) refInp(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) datum(601) austron(3) products(1) ssu2000(1) ref(7) refInp(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) datum(601) austron(3) products(1) ssu2000(1) ref(7) refInp(2)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) datum(601) austron(3) products(1) ssu2000(1) ref(7) refInp(2)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) datum(601) austron(3) products(1) ssu2000(1) ref(7) refInp(2)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) datum(601) austron(3) products(1) ssu2000(1) ref(7) refInp(2)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) datum(601) austron(3) products(1) ssu2000(1) ref(7) refInp(2)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) datum(601) austron(3) products(1) ssu2000(1) ref(7) refInp(2)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) datum(601) austron(3) products(1) ssu2000(1) ref(7) refInp(2)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) datum(601) austron(3) products(1) ssu2000(1) ref(7) refInp(2)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) datum(601) austron(3) products(1) ssu2000(1) ref(7) refInp(2)}
OID-IRI notation
  • /1/3/6/1/4/1/601/3/1/1/7/2
  • /ISO/Identified-Organization/6/1/4/1/601/3/1/1/7/2
  • /ISO/3/6/1/4/1/601/3/1/1/7/2
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/601/austron/products/ssu2000/ref/refInp
  • /iso/identified-organization/dod/internet/private/enterprise/datum/austron/products/ssu2000/ref/refInp
  • /iso/identified-organization/dod/internet/private/enterprises/601/austron/products/ssu2000/ref/refInp
  • /iso/identified-organization/dod/internet/private/enterprises/datum/austron/products/ssu2000/ref/refInp
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/601/austron/products/ssu2000/ref/refInp
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/datum/austron/products/ssu2000/ref/refInp
  • /iso/identified-organization/dod/internet/private/vendor-objects/601/austron/products/ssu2000/ref/refInp
  • /iso/identified-organization/dod/internet/private/vendor-objects/datum/austron/products/ssu2000/ref/refInp
  • /iso/org/dod/internet/private/enterprise/601/austron/products/ssu2000/ref/refInp
  • /iso/org/dod/internet/private/enterprise/datum/austron/products/ssu2000/ref/refInp
  • /iso/org/dod/internet/private/enterprises/601/austron/products/ssu2000/ref/refInp
  • /iso/org/dod/internet/private/enterprises/datum/austron/products/ssu2000/ref/refInp
  • /iso/org/dod/internet/private/ldap-enterprise/601/austron/products/ssu2000/ref/refInp
  • /iso/org/dod/internet/private/ldap-enterprise/datum/austron/products/ssu2000/ref/refInp
  • /iso/org/dod/internet/private/vendor-objects/601/austron/products/ssu2000/ref/refInp
  • /iso/org/dod/internet/private/vendor-objects/datum/austron/products/ssu2000/ref/refInp
  • Additional combinations skipped.

SNMP properties

Value type
DisplayString
Maximum access defined by MIB
read-write
Status in MIB
current
Allowed size (octets)
0–10

Using this OID with SNMP

At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.

snmpget [connection options] DEVICE .1.3.6.1.4.1.601.3.1.1.7.2.0

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

The displayed source records contain one distinct definition. Compare its source records.

refInp OBJECT-TYPE
        SYNTAX  DisplayString (SIZE (0..10))
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
        "Report/Set the input reference port.
        The format is defined as xAy-z.
        where
        x is the chassis number: in this case is 1,
        A is the constant letter 'A', and is chassis/slot sepearator.
        y is the slot number: (range is 3 to 11)
        - is the constant letter '-', and is slot/port sepearator
        z is the port number (1 to 3).

        For example: 1A3-1 means this input port located at chassis 1, slot 3, and port 1.
        The NULL string means there is no input reference.
        "
    ::= { ref 2 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Report/Set the input reference port. The format is defined as xAy-z. where x is the chassis number: in this case is 1, A is the constant letter 'A', and is chassis/slot sepearator. y is the slot number: (range is 3 to 11) - is the constant letter '-', and is slot/port sepearator z is the port number (1 to 3). For example: 1A3-1 means this input port located at chassis 1, slot 3, and port 1. The NULL string means there is no input reference.

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 1

refInp · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: refInp

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "refInp",
    "OBJECT-TYPE",
    "SYNTAX",
    "DisplayString",
    "(",
    "SIZE",
    "(",
    "0",
    ".",
    ".",
    "10",
    ")",
    ")",
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Report/Set the input reference port. The format is defined as xAy-z. where x is the chassis number: in this case is 1, A is the constant letter 'A', and is chassis/slot sepearator. y is the slot number: (range is 3 to 11) - is the constant letter '-', and is slot/port sepearator z is the port number (1 to 3). For example: 1A3-1 means this input port located at chassis 1, slot 3, and port 1. The NULL string means there is no input reference. \"",
    "::=",
    "{",
    "ref",
    "2",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "DisplayString",
      [
        "octetStringSubType",
        [
          [
            0,
            10
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Report/Set the input reference port. The format is defined as xAy-z. where x is the chassis number: in this case is 1, A is the constant letter 'A', and is chassis/slot sepearator. y is the slot number: (range is 3 to 11) - is the constant letter '-', and is slot/port sepearator z is the port number (1 to 3). For example: 1A3-1 means this input port located at chassis 1, slot 3, and port 1. The NULL string means there is no input reference."
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.601)

Fontes Joe

Siblings (6)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.601.3.1.1.7.1 refClk00
1.3.6.1.4.1.601.3.1.1.7.3 refBypass00
1.3.6.1.4.1.601.3.1.1.7.4 refClkSwitch00
1.3.6.1.4.1.601.3.1.1.7.5 refInpSwitch00
1.3.6.1.4.1.601.3.1.1.7.6 refInpSelection00
1.3.6.1.4.1.601.3.1.1.7.7 refClkTodsrc00