This mib module describes objects used to perform Metallic Line Testing on customer access lines and to provide results.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.6066.2.1.1.3
This mib module describes objects used to perform Metallic Line Testing on customer access lines and to provide results.
Identification
{1 3 6 1 4 1 6066 2 1 1 3}
The displayed source records contain one distinct definition. Compare its source records.
occamMltMib MODULE-IDENTITY
LAST-UPDATED "200104271051Z"
ORGANIZATION "Occam Networks"
CONTACT-INFO "email support@occamnetworks.com"
DESCRIPTION
"This mib module describes objects used
to perform Metallic Line Testing on customer
access lines and to provide results."
REVISION "200104271051Z"
DESCRIPTION "Reformatted certain text"
REVISION "200704170000Z"
DESCRIPTION "replace kOhm with Ohm in DC resistance
UNITS"
REVISION "200702220000Z"
DESCRIPTION "remove DISPLAY-HINT"
REVISION "200609261000Z"
DESCRIPTION "Removed Gr909 from fuse test result names"
REVISION "200602220135Z"
DESCRIPTION "Initial version."
::= { occamGenericMonitorModules 3 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
This mib module describes objects used to perform Metallic Line Testing on customer access lines and to provide results.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: unspecified.
Names: occamMltMib
{
"smi_kind": "MODULE-IDENTITY",
"definition": [
"occamMltMib",
"MODULE-IDENTITY",
"LAST-UPDATED",
[
"literal",
"223230303130343237313035315a22"
],
"ORGANIZATION",
"\"Occam Networks\"",
"CONTACT-INFO",
"\"email support@occamnetworks.com\"",
"DESCRIPTION",
"\"This mib module describes objects used to perform Metallic Line Testing on customer access lines and to provide results.\"",
"REVISION",
[
"literal",
"223230303130343237313035315a22"
],
"DESCRIPTION",
"\"Reformatted certain text\"",
"REVISION",
[
"literal",
"223230303730343137303030305a22"
],
"DESCRIPTION",
"\"replace kOhm with Ohm in DC resistance UNITS\"",
"REVISION",
[
"literal",
"223230303730323232303030305a22"
],
"DESCRIPTION",
"\"remove DISPLAY-HINT\"",
"REVISION",
[
"literal",
"223230303630393236313030305a22"
],
"DESCRIPTION",
"\"Removed Gr909 from fuse test result names\"",
"REVISION",
[
"literal",
"223230303630323232303133355a22"
],
"DESCRIPTION",
"\"Initial version.\"",
"::=",
"{",
"occamGenericMonitorModules",
"3",
"}"
],
"syntax_tree": [
[
"LAST-UPDATED",
"200104271051Z"
],
[
"ORGANIZATION",
"Occam Networks"
],
[
"CONTACT-INFO",
"email support@occamnetworks.com"
],
[
"DESCRIPTION",
"This mib module describes objects used to perform Metallic Line Testing on customer access lines and to provide results."
],
[
"Revisions",
[
[
"200104271051Z",
[
"DESCRIPTION",
"Reformatted certain text"
]
],
[
"200704170000Z",
[
"DESCRIPTION",
"replace kOhm with Ohm in DC resistance UNITS"
]
],
[
"200702220000Z",
[
"DESCRIPTION",
"remove DISPLAY-HINT"
]
],
[
"200609261000Z",
[
"DESCRIPTION",
"Removed Gr909 from fuse test result names"
]
],
[
"200602220135Z",
[
"DESCRIPTION",
"Initial version."
]
]
]
]
]
}Vendor MIB copy from the LibreNMS archive.
Module: OCCAM-MLT-MIB
See published definition above
{'SNMPv2-TC': ['TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'OBJECT-IDENTITY', 'Integer32', 'NOTIFICATION-TYPE'], 'OCCAM-REG-MODULE': ['occamGenericMonitorModules']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.6066.2.1.1.3.1 | mltTestConfig | 6 | 6 | |
| 1.3.6.1.4.1.6066.2.1.1.3.2 | mltTestStatus | 2 | 2 | |
| 1.3.6.1.4.1.6066.2.1.1.3.3 | mltTestResults | 8 | 95 | |
| 1.3.6.1.4.1.6066.2.1.1.3.4 | mltTestNotifications | 1 | 1 |