LNB power control, where: 0 = Off 1 = On, 13V LNB voltage 2 = On, 18V LNB voltage 3 = On, 24V LNB voltage
Sources for this description
Comtech EF Data MIB copies (MibBrowser.online)
OID reference
1.3.6.1.4.1.6247.25.1.7.4.1.1.2
LNB power control, where: 0 = Off 1 = On, 13V LNB voltage 2 = On, 18V LNB voltage 3 = On, 24V LNB voltage
Identification
{1 3 6 1 4 1 6247 25 1 7 4 1 1 2}
| Value | Name |
|---|---|
| 0 | off |
| 1 | on13volts |
| 2 | on18volts |
| 3 | on24volts |
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.
In CDD-564, the row index cdd564LNBIndex is declared as INTEGER. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.6247.25.1.7.4.1.1.2.<cdd564LNBIndex>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.6247.25.1.7.4.1.1.2
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
cdd564LNBDCPower OBJECT-TYPE
SYNTAX INTEGER
{
off(0),
on13volts(1),
on18volts(2),
on24volts(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"LNB power control, where:
0 = Off
1 = On, 13V LNB voltage
2 = On, 18V LNB voltage
3 = On, 24V LNB voltage"
::= { cdd564LNBEntry 2 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
LNB power control, where: 0 = Off 1 = On, 13V LNB voltage 2 = On, 18V LNB voltage 3 = On, 24V LNB voltage
Comtech EF Data MIB copies (MibBrowser.online)
Evidence
Matching descriptions are grouped; representative source files are shown for each definition.
Status in source: current.
Names: cdd564LNBDCPower
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"cdd564LNBDCPower",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"off",
"(",
"0",
")",
",",
"on13volts",
"(",
"1",
")",
",",
"on18volts",
"(",
"2",
")",
",",
"on24volts",
"(",
"3",
")",
"}",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"LNB power control, where: 0 = Off 1 = On, 13V LNB voltage 2 = On, 18V LNB voltage 3 = On, 24V LNB voltage\"",
"::=",
"{",
"cdd564LNBEntry",
"2",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"off",
0
],
[
"on13volts",
1
],
[
"on18volts",
2
],
[
"on24volts",
3
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"LNB power control, where: 0 = Off 1 = On, 13V LNB voltage 2 = On, 18V LNB voltage 3 = On, 24V LNB voltage"
],
null,
null,
null,
null
]
}Vendor MIB copy from the MibBrowser.online archive. Comtech EF Data support.
Module: CDD-564
See published definition above
{'SNMPv2-TC': ['DisplayString'], 'SNMPv2-SMI': ['IpAddress', 'Counter32', 'OBJECT-TYPE', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE', 'NOTIFICATION-GROUP'], 'ComtechEFData': ['comtechEFData']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.6247.25.1.7.4.1.1.1 | cdd564LNBIndex | 0 | 0 | |
| 1.3.6.1.4.1.6247.25.1.7.4.1.1.3 | cdd564LNB10MHzReference | 0 | 0 | |
| 1.3.6.1.4.1.6247.25.1.7.4.1.1.4 | cdm564LLNBLowCurrentLimit | 0 | 0 | |
| 1.3.6.1.4.1.6247.25.1.7.4.1.1.5 | cdd564LNBHighCurrentLimit | 0 | 0 | |
| 1.3.6.1.4.1.6247.25.1.7.4.1.1.6 | cdd564LNBLOFrequency | 0 | 0 | |
| 1.3.6.1.4.1.6247.25.1.7.4.1.1.7 | cdd564LNBLOMix | 0 | 0 |