Unit returns the value of the Rx signal level, in dBm, between -20 and -99 dBm, Returns -100 if signal is less than -99dBm. Returns -19 if signal is greater than -20dBm.
Sources for this description
Comtech EF Data MIB copies (MibBrowser.online)
OID reference
1.3.6.1.4.1.6247.25.1.8.2.1.1.4
Unit returns the value of the Rx signal level, in dBm, between -20 and -99 dBm, Returns -100 if signal is less than -99dBm. Returns -19 if signal is greater than -20dBm.
Identification
{1 3 6 1 4 1 6247 25 1 8 2 1 1 4}
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.
In CDD-564, the row index cdd564RxMonitorIndex is declared as INTEGER. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.6247.25.1.8.2.1.1.4.<cdd564RxMonitorIndex>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.6247.25.1.8.2.1.1.4
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
cdd564RxSignalLevel OBJECT-TYPE
SYNTAX INTEGER (-100 | -99..-20 | -19)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unit returns the value of the Rx signal level,
in dBm, between -20 and -99 dBm,
Returns -100 if signal is less than -99dBm.
Returns -19 if signal is greater than -20dBm."
::= { cdd564RxMonitorEntry 4 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Unit returns the value of the Rx signal level, in dBm, between -20 and -99 dBm, Returns -100 if signal is less than -99dBm. Returns -19 if signal is greater than -20dBm.
Comtech EF Data MIB copies (MibBrowser.online)
Evidence
Matching descriptions are grouped; representative source files are shown for each definition.
Status in source: current.
Names: cdd564RxSignalLevel
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"cdd564RxSignalLevel",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"(",
"-",
"100",
"|",
"-",
"99",
".",
".",
"-",
"20",
"|",
"-",
"19",
")",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"Unit returns the value of the Rx signal level, in dBm, between -20 and -99 dBm, Returns -100 if signal is less than -99dBm. Returns -19 if signal is greater than -20dBm.\"",
"::=",
"{",
"cdd564RxMonitorEntry",
"4",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"integerSubType",
[
[
-100
],
[
-99,
-20
],
[
-19
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Unit returns the value of the Rx signal level, in dBm, between -20 and -99 dBm, Returns -100 if signal is less than -99dBm. Returns -19 if signal is greater than -20dBm."
],
null,
null,
null,
null
]
}Vendor MIB copy from the MibBrowser.online archive. Comtech EF Data support.
Module: CDD-564
See published definition above
{'SNMPv2-TC': ['DisplayString'], 'SNMPv2-SMI': ['IpAddress', 'Counter32', 'OBJECT-TYPE', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE', 'NOTIFICATION-GROUP'], 'ComtechEFData': ['comtechEFData']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.6247.25.1.8.2.1.1.1 | cdd564RxMonitorIndex | 0 | 0 | |
| 1.3.6.1.4.1.6247.25.1.8.2.1.1.2 | cdd564RxAlarm | 0 | 0 | |
| 1.3.6.1.4.1.6247.25.1.8.2.1.1.3 | cdd564RxEbNo | 0 | 0 | |
| 1.3.6.1.4.1.6247.25.1.8.2.1.1.5 | cdd564RxFreqOffset | 0 | 0 | |
| 1.3.6.1.4.1.6247.25.1.8.2.1.1.7 | cddRxBERMultiplier | 0 | 0 |