Indicates the value of the LNB voltage, between 0 and 30 volts. Units = 0.1 volts If not available, response is 0.
Sources for this description
Comtech EF Data MIB copies (MibBrowser.online)
OID reference
1.3.6.1.4.1.6247.25.1.8.3.1.1.4
Indicates the value of the LNB voltage, between 0 and 30 volts. Units = 0.1 volts If not available, response is 0.
Identification
{1 3 6 1 4 1 6247 25 1 8 3 1 1 4}
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.
In CDD-564, the row index cdd564LNBMonitorIndex is declared as INTEGER. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.6247.25.1.8.3.1.1.4.<cdd564LNBMonitorIndex>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.6247.25.1.8.3.1.1.4
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
cdd564LNBVoltage OBJECT-TYPE
SYNTAX INTEGER (0..300)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the value of the LNB voltage,
between 0 and 30 volts.
Units = 0.1 volts
If not available, response is 0."
::= { cdd564LNBMonitorEntry 4 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Indicates the value of the LNB voltage, between 0 and 30 volts. Units = 0.1 volts If not available, response is 0.
Comtech EF Data MIB copies (MibBrowser.online)
Evidence
Matching descriptions are grouped; representative source files are shown for each definition.
Status in source: current.
Names: cdd564LNBVoltage
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"cdd564LNBVoltage",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"(",
"0",
".",
".",
"300",
")",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"Indicates the value of the LNB voltage, between 0 and 30 volts. Units = 0.1 volts If not available, response is 0.\"",
"::=",
"{",
"cdd564LNBMonitorEntry",
"4",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"integerSubType",
[
[
0,
300
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Indicates the value of the LNB voltage, between 0 and 30 volts. Units = 0.1 volts If not available, response is 0."
],
null,
null,
null,
null
]
}Vendor MIB copy from the MibBrowser.online archive. Comtech EF Data support.
Module: CDD-564
See published definition above
{'SNMPv2-TC': ['DisplayString'], 'SNMPv2-SMI': ['IpAddress', 'Counter32', 'OBJECT-TYPE', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE', 'NOTIFICATION-GROUP'], 'ComtechEFData': ['comtechEFData']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.6247.25.1.8.3.1.1.1 | cdd564LNBMonitorIndex | 0 | 0 | |
| 1.3.6.1.4.1.6247.25.1.8.3.1.1.2 | cdd564LNBAlarm | 0 | 0 | |
| 1.3.6.1.4.1.6247.25.1.8.3.1.1.3 | cdd564LNBCurrent | 0 | 0 | |
| 1.3.6.1.4.1.6247.25.1.8.3.1.1.5 | cdd564LNBTerminalRxFreq | 0 | 0 |