Reference record for OID 1.3.6.1.4.1.62698.2.10.2.2.10.4.5.1.11

Parent
1.3.6.1.4.1.62698.2.10.2.2.10.4.5.1 (sc2PowerMonitoring-2)
Node code
11
Node name
sc2pmPowerControlMode-2
Numeric OID
1.3.6.1.4.1.62698.2.10.2.2.10.4.5.1.11
URN notation
urn:oid:1.3.6.1.4.1.62698.2.10.2.2.10.4.5.1.11
ASN.1 notation

{1 3 6 1 4 1 62698 2 10 2 2 10 4 5 1 11}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) fsas-technologies(62698) sniProductMibs-2(2) sniExtensions-2(10) sniServerMgmt-2(2) sniCommon-2(2) fscServerControl2-2(10) sc2ServerInformation-2(4) sc2PowerMonitoringTable-2(5) sc2PowerMonitoring-2(1) sc2pmPowerControlMode-2(11)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) fsas-technologies(62698) sniProductMibs-2(2) sniExtensions-2(10) sniServerMgmt-2(2) sniCommon-2(2) fscServerControl2-2(10) sc2ServerInformation-2(4) sc2PowerMonitoringTable-2(5) sc2PowerMonitoring-2(1) sc2pmPowerControlMode-2(11)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) fsas-technologies(62698) sniProductMibs-2(2) sniExtensions-2(10) sniServerMgmt-2(2) sniCommon-2(2) fscServerControl2-2(10) sc2ServerInformation-2(4) sc2PowerMonitoringTable-2(5) sc2PowerMonitoring-2(1) sc2pmPowerControlMode-2(11)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) fsas-technologies(62698) sniProductMibs-2(2) sniExtensions-2(10) sniServerMgmt-2(2) sniCommon-2(2) fscServerControl2-2(10) sc2ServerInformation-2(4) sc2PowerMonitoringTable-2(5) sc2PowerMonitoring-2(1) sc2pmPowerControlMode-2(11)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) fsas-technologies(62698) sniProductMibs-2(2) sniExtensions-2(10) sniServerMgmt-2(2) sniCommon-2(2) fscServerControl2-2(10) sc2ServerInformation-2(4) sc2PowerMonitoringTable-2(5) sc2PowerMonitoring-2(1) sc2pmPowerControlMode-2(11)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) fsas-technologies(62698) sniProductMibs-2(2) sniExtensions-2(10) sniServerMgmt-2(2) sniCommon-2(2) fscServerControl2-2(10) sc2ServerInformation-2(4) sc2PowerMonitoringTable-2(5) sc2PowerMonitoring-2(1) sc2pmPowerControlMode-2(11)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) fsas-technologies(62698) sniProductMibs-2(2) sniExtensions-2(10) sniServerMgmt-2(2) sniCommon-2(2) fscServerControl2-2(10) sc2ServerInformation-2(4) sc2PowerMonitoringTable-2(5) sc2PowerMonitoring-2(1) sc2pmPowerControlMode-2(11)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) fsas-technologies(62698) sniProductMibs-2(2) sniExtensions-2(10) sniServerMgmt-2(2) sniCommon-2(2) fscServerControl2-2(10) sc2ServerInformation-2(4) sc2PowerMonitoringTable-2(5) sc2PowerMonitoring-2(1) sc2pmPowerControlMode-2(11)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) fsas-technologies(62698) sniProductMibs-2(2) sniExtensions-2(10) sniServerMgmt-2(2) sniCommon-2(2) fscServerControl2-2(10) sc2ServerInformation-2(4) sc2PowerMonitoringTable-2(5) sc2PowerMonitoring-2(1) sc2pmPowerControlMode-2(11)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) fsas-technologies(62698) sniProductMibs-2(2) sniExtensions-2(10) sniServerMgmt-2(2) sniCommon-2(2) fscServerControl2-2(10) sc2ServerInformation-2(4) sc2PowerMonitoringTable-2(5) sc2PowerMonitoring-2(1) sc2pmPowerControlMode-2(11)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) fsas-technologies(62698) sniProductMibs-2(2) sniExtensions-2(10) sniServerMgmt-2(2) sniCommon-2(2) fscServerControl2-2(10) sc2ServerInformation-2(4) sc2PowerMonitoringTable-2(5) sc2PowerMonitoring-2(1) sc2pmPowerControlMode-2(11)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) fsas-technologies(62698) sniProductMibs-2(2) sniExtensions-2(10) sniServerMgmt-2(2) sniCommon-2(2) fscServerControl2-2(10) sc2ServerInformation-2(4) sc2PowerMonitoringTable-2(5) sc2PowerMonitoring-2(1) sc2pmPowerControlMode-2(11)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) fsas-technologies(62698) sniProductMibs-2(2) sniExtensions-2(10) sniServerMgmt-2(2) sniCommon-2(2) fscServerControl2-2(10) sc2ServerInformation-2(4) sc2PowerMonitoringTable-2(5) sc2PowerMonitoring-2(1) sc2pmPowerControlMode-2(11)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) fsas-technologies(62698) sniProductMibs-2(2) sniExtensions-2(10) sniServerMgmt-2(2) sniCommon-2(2) fscServerControl2-2(10) sc2ServerInformation-2(4) sc2PowerMonitoringTable-2(5) sc2PowerMonitoring-2(1) sc2pmPowerControlMode-2(11)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) fsas-technologies(62698) sniProductMibs-2(2) sniExtensions-2(10) sniServerMgmt-2(2) sniCommon-2(2) fscServerControl2-2(10) sc2ServerInformation-2(4) sc2PowerMonitoringTable-2(5) sc2PowerMonitoring-2(1) sc2pmPowerControlMode-2(11)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) fsas-technologies(62698) sniProductMibs-2(2) sniExtensions-2(10) sniServerMgmt-2(2) sniCommon-2(2) fscServerControl2-2(10) sc2ServerInformation-2(4) sc2PowerMonitoringTable-2(5) sc2PowerMonitoring-2(1) sc2pmPowerControlMode-2(11)}
OID-IRI notation
  • /1/3/6/1/4/1/62698/2/10/2/2/10/4/5/1/11
  • /ISO/Identified-Organization/6/1/4/1/62698/2/10/2/2/10/4/5/1/11
  • /ISO/3/6/1/4/1/62698/2/10/2/2/10/4/5/1/11
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/fsas-technologies/sniProductMibs-2/sniExtensions-2/sniServerMgmt-2/sniCommon-2/fscServerControl2-2/sc2ServerInformation-2/sc2PowerMonitoringTable-2/sc2PowerMonitoring-2/sc2pmPowerControlMode-2
  • /iso/identified-organization/dod/internet/private/enterprises/fsas-technologies/sniProductMibs-2/sniExtensions-2/sniServerMgmt-2/sniCommon-2/fscServerControl2-2/sc2ServerInformation-2/sc2PowerMonitoringTable-2/sc2PowerMonitoring-2/sc2pmPowerControlMode-2
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/fsas-technologies/sniProductMibs-2/sniExtensions-2/sniServerMgmt-2/sniCommon-2/fscServerControl2-2/sc2ServerInformation-2/sc2PowerMonitoringTable-2/sc2PowerMonitoring-2/sc2pmPowerControlMode-2
  • /iso/identified-organization/dod/internet/private/vendor-objects/fsas-technologies/sniProductMibs-2/sniExtensions-2/sniServerMgmt-2/sniCommon-2/fscServerControl2-2/sc2ServerInformation-2/sc2PowerMonitoringTable-2/sc2PowerMonitoring-2/sc2pmPowerControlMode-2
  • /iso/org/dod/internet/private/enterprise/fsas-technologies/sniProductMibs-2/sniExtensions-2/sniServerMgmt-2/sniCommon-2/fscServerControl2-2/sc2ServerInformation-2/sc2PowerMonitoringTable-2/sc2PowerMonitoring-2/sc2pmPowerControlMode-2
  • /iso/org/dod/internet/private/enterprises/fsas-technologies/sniProductMibs-2/sniExtensions-2/sniServerMgmt-2/sniCommon-2/fscServerControl2-2/sc2ServerInformation-2/sc2PowerMonitoringTable-2/sc2PowerMonitoring-2/sc2pmPowerControlMode-2
  • /iso/org/dod/internet/private/ldap-enterprise/fsas-technologies/sniProductMibs-2/sniExtensions-2/sniServerMgmt-2/sniCommon-2/fscServerControl2-2/sc2ServerInformation-2/sc2PowerMonitoringTable-2/sc2PowerMonitoring-2/sc2pmPowerControlMode-2
  • /iso/org/dod/internet/private/vendor-objects/fsas-technologies/sniProductMibs-2/sniExtensions-2/sniServerMgmt-2/sniCommon-2/fscServerControl2-2/sc2ServerInformation-2/sc2PowerMonitoringTable-2/sc2PowerMonitoring-2/sc2pmPowerControlMode-2
  • /iso/iso-identified-organization/dod/internet/private/enterprise/fsas-technologies/sniProductMibs-2/sniExtensions-2/sniServerMgmt-2/sniCommon-2/fscServerControl2-2/sc2ServerInformation-2/sc2PowerMonitoringTable-2/sc2PowerMonitoring-2/sc2pmPowerControlMode-2
  • /iso/iso-identified-organization/dod/internet/private/enterprises/fsas-technologies/sniProductMibs-2/sniExtensions-2/sniServerMgmt-2/sniCommon-2/fscServerControl2-2/sc2ServerInformation-2/sc2PowerMonitoringTable-2/sc2PowerMonitoring-2/sc2pmPowerControlMode-2
  • /iso/iso-identified-organization/dod/internet/private/ldap-enterprise/fsas-technologies/sniProductMibs-2/sniExtensions-2/sniServerMgmt-2/sniCommon-2/fscServerControl2-2/sc2ServerInformation-2/sc2PowerMonitoringTable-2/sc2PowerMonitoring-2/sc2pmPowerControlMode-2
  • /iso/iso-identified-organization/dod/internet/private/vendor-objects/fsas-technologies/sniProductMibs-2/sniExtensions-2/sniServerMgmt-2/sniCommon-2/fscServerControl2-2/sc2ServerInformation-2/sc2PowerMonitoringTable-2/sc2PowerMonitoring-2/sc2pmPowerControlMode-2
  • /iso/iso-organization/dod/internet/private/enterprise/fsas-technologies/sniProductMibs-2/sniExtensions-2/sniServerMgmt-2/sniCommon-2/fscServerControl2-2/sc2ServerInformation-2/sc2PowerMonitoringTable-2/sc2PowerMonitoring-2/sc2pmPowerControlMode-2
  • /iso/iso-organization/dod/internet/private/enterprises/fsas-technologies/sniProductMibs-2/sniExtensions-2/sniServerMgmt-2/sniCommon-2/fscServerControl2-2/sc2ServerInformation-2/sc2PowerMonitoringTable-2/sc2PowerMonitoring-2/sc2pmPowerControlMode-2
  • /iso/iso-organization/dod/internet/private/ldap-enterprise/fsas-technologies/sniProductMibs-2/sniExtensions-2/sniServerMgmt-2/sniCommon-2/fscServerControl2-2/sc2ServerInformation-2/sc2PowerMonitoringTable-2/sc2PowerMonitoring-2/sc2pmPowerControlMode-2
  • /iso/iso-organization/dod/internet/private/vendor-objects/fsas-technologies/sniProductMibs-2/sniExtensions-2/sniServerMgmt-2/sniCommon-2/fscServerControl2-2/sc2ServerInformation-2/sc2PowerMonitoringTable-2/sc2PowerMonitoring-2/sc2pmPowerControlMode-2

Descriptions

sc2pmPowerControlMode-2 — Fujitsu and Fsas ServerView ServerControl MIBs (official package)

Configured power control mode value: disabled: The baseboard management controller does not control the power saving behaviour best-performance: The baseboard management controller gives best performance to the system (power consumption may be increased) minimum-power: The baseboard management controller controls the system in way to consume minimum power (performance may be reduced) automatic: The baseboard management controller automatically controls power consumption between good performance and low power consumption scheduled: The baseboard management controller controls power consumption by schedule limited: The baseboard management controller controls power consumption by power limit low-noise: The baseboard management controller controls the power to ensure running with lowest noise

Source records

sc2pmPowerControlMode-2

Status in source: mandatory.

Names: sc2pmPowerControlMode-2

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "sc2pmPowerControlMode-2",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "unknown",
    "(",
    "1",
    ")",
    ",",
    "disabled",
    "(",
    "2",
    ")",
    ",",
    "best-performance",
    "(",
    "3",
    ")",
    ",",
    "minimum-power",
    "(",
    "4",
    ")",
    ",",
    "automatic",
    "(",
    "5",
    ")",
    ",",
    "scheduled",
    "(",
    "6",
    ")",
    ",",
    "limited",
    "(",
    "7",
    ")",
    ",",
    "low-noise",
    "(",
    "8",
    ")",
    "}",
    "ACCESS",
    "read-only",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"Configured power control mode value: disabled: The baseboard management controller does not control the power saving behaviour best-performance: The baseboard management controller gives best performance to the system (power consumption may be increased) minimum-power: The baseboard management controller controls the system in way to consume minimum power (performance may be reduced) automatic: The baseboard management controller automatically controls power consumption between good performance and low power consumption scheduled: The baseboard management controller controls power consumption by schedule limited: The baseboard management controller controls power consumption by power limit low-noise: The baseboard management controller controls the power to ensure running with lowest noise\"",
    "::=",
    "{",
    "sc2PowerMonitoring-2",
    "11",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "unknown",
            1
          ],
          [
            "disabled",
            2
          ],
          [
            "best-performance",
            3
          ],
          [
            "minimum-power",
            4
          ],
          [
            "automatic",
            5
          ],
          [
            "scheduled",
            6
          ],
          [
            "limited",
            7
          ],
          [
            "low-noise",
            8
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "Configured power control mode value: disabled: The baseboard management controller does not control the power saving behaviour best-performance: The baseboard management controller gives best performance to the system (power consumption may be increased) minimum-power: The baseboard management controller controls the system in way to consume minimum power (performance may be reduced) automatic: The baseboard management controller automatically controls power consumption between good performance and low power consumption scheduled: The baseboard management controller controls power consumption by schedule limited: The baseboard management controller controls power consumption by power limit low-noise: The baseboard management controller controls the power to ensure running with lowest noise"
    ],
    null,
    null,
    null,
    null
  ]
}
  • Fujitsu and Fsas ServerView ServerControl MIBs (official package) · Publisher's source file: Source package: SNMPMIBs.zip

    Module: FSC-SERVERCONTROL2-MIB-2

    Published definition
    sc2pmPowerControlMode-2 OBJECT-TYPE
        SYNTAX       INTEGER
        {
            unknown(1),
            disabled(2),
            best-performance(3),
            minimum-power(4),
            automatic(5),
            scheduled(6),
            limited(7),
            low-noise(8)
        }
        ACCESS       read-only
        STATUS       mandatory
        DESCRIPTION  "Configured power control mode value:
                         disabled:         The baseboard management controller does not control the power saving behaviour
                         best-performance: The baseboard management controller gives best performance to the system (power consumption may be increased)
                         minimum-power:    The baseboard management controller controls the system in way to consume minimum power (performance may be reduced)
                         automatic:        The baseboard management controller automatically controls power consumption between good performance and low power consumption
                         scheduled:        The baseboard management controller controls power consumption by schedule
                         limited:          The baseboard management controller controls power consumption by power limit
                         low-noise:        The baseboard management controller controls the power to ensure running with lowest noise"
        ::= { sc2PowerMonitoring-2 11 }
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC1155-SMI': ['Counter', 'Gauge', 'IpAddress'], 'RFC1213-MIB': ['mib-2', 'DisplayString']}
    · Download Fujitsu ServerControl MIB — SC2-2.mib

    Related source files and packages:


    Source location: FSC-SERVERCONTROL2-MIB-2::sc2pmPowerControlMode-2.
    Source version and references

    ServerView ServerControl MIB distributed in the official Fujitsu package. This edition uses the Fsas Technologies enterprise number 62698.; Publisher path: prim_supportcd/SVSSoftware/Software/ServerView/MIBs/SNMPMIBs.zip; 245,390 bytes

    Downloaded: 2026-11-03T05:49:44.885211+00:00.

Current Registration Authority (inferred from ancestor 1.3.6.1.4.1.62698)

Fsas Technologies Inc.

Siblings (11)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.62698.2.10.2.2.10.4.5.1.1 sc2pmUnitId-200
1.3.6.1.4.1.62698.2.10.2.2.10.4.5.1.2 sc2pmCurrentPowerMonitoringAvailable-200
1.3.6.1.4.1.62698.2.10.2.2.10.4.5.1.3 sc2pmCurrentPowerMonitoringEnabled-200
1.3.6.1.4.1.62698.2.10.2.2.10.4.5.1.4 sc2pmNominalPowerConsumption-200
1.3.6.1.4.1.62698.2.10.2.2.10.4.5.1.5 sc2pmCurrentPowerConsumption-200
1.3.6.1.4.1.62698.2.10.2.2.10.4.5.1.6 sc2pmCurrentPowerControl-200
1.3.6.1.4.1.62698.2.10.2.2.10.4.5.1.7 sc2pmPowerLimitStatus-200
1.3.6.1.4.1.62698.2.10.2.2.10.4.5.1.8 sc2pmPowerLimitThreshold-200
1.3.6.1.4.1.62698.2.10.2.2.10.4.5.1.9 sc2pmPowerLimitWarning-200
1.3.6.1.4.1.62698.2.10.2.2.10.4.5.1.10 sc2pmRedundancyCritLevel-200
1.3.6.1.4.1.62698.2.10.2.2.10.4.5.1.12 sc2pmPowerDisplayUnit-200