Status in source: mandatory.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"svrLogicalDriveStatusEx-2",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"unknown",
"(",
"1",
")",
",",
"operational",
"(",
"2",
")",
",",
"partiallyDegraded",
"(",
"3",
")",
",",
"degraded",
"(",
"4",
")",
",",
"failed",
"(",
"5",
")",
",",
"rebuilding",
"(",
"6",
")",
",",
"checking",
"(",
"7",
")",
",",
"mdcing",
"(",
"8",
")",
",",
"initializing",
"(",
"9",
")",
",",
"backgroundInitializing",
"(",
"10",
")",
",",
"migrating",
"(",
"11",
")",
",",
"copying",
"(",
"12",
")",
",",
"offline",
"(",
"13",
")",
",",
"spareInUse",
"(",
"14",
")",
",",
"erasing",
"(",
"15",
")",
"}",
"ACCESS",
"read-only",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"Status of the logical drive: operational(2): drive is OK, all disks working properly partiallyDegraded(3): one disk in this array failed, reduced redundancy still available degraded(4): one disk in this array failed, redundancy lost failed(5): too many disks in this array failed, drive no longer available rebuilding(6): drive is currently rebuilding checking(7): drive is currently executing a consistency check mdcing(8): drive is currently executing a consistency check and fixes inconsistencies initializing(9): drive is currently being initialized backgroundInitializing(10): drive is currently being initialized in background migrating(11): drive is currently being modified (online RAID extension) copying(12): drive is currently executing a copyback or redundant copy operation offline(13): drive is temporarily not operational spareInUse(14): drive is using a hot spare erasing(15): drive is being erased\"",
"::=",
"{",
"svrLogicalDriveEntry-2",
"19",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"unknown",
1
],
[
"operational",
2
],
[
"partiallyDegraded",
3
],
[
"degraded",
4
],
[
"failed",
5
],
[
"rebuilding",
6
],
[
"checking",
7
],
[
"mdcing",
8
],
[
"initializing",
9
],
[
"backgroundInitializing",
10
],
[
"migrating",
11
],
[
"copying",
12
],
[
"offline",
13
],
[
"spareInUse",
14
],
[
"erasing",
15
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"Status of the logical drive: operational(2): drive is OK, all disks working properly partiallyDegraded(3): one disk in this array failed, reduced redundancy still available degraded(4): one disk in this array failed, redundancy lost failed(5): too many disks in this array failed, drive no longer available rebuilding(6): drive is currently rebuilding checking(7): drive is currently executing a consistency check mdcing(8): drive is currently executing a consistency check and fixes inconsistencies initializing(9): drive is currently being initialized backgroundInitializing(10): drive is currently being initialized in background migrating(11): drive is currently being modified (online RAID extension) copying(12): drive is currently executing a copyback or redundant copy operation offline(13): drive is temporarily not operational spareInUse(14): drive is using a hot spare erasing(15): drive is being erased"
],
null,
null,
null,
null
]
}