Reference record for OID 1.3.6.1.4.1.62698.2.49.2.0.10062

Parent
1.3.6.1.4.1.62698.2.49.2.0 (0)
Node code
10062
Node name
svrTrapLDConCheckFailed-2
Numeric OID
1.3.6.1.4.1.62698.2.49.2.0.10062
URN notation
urn:oid:1.3.6.1.4.1.62698.2.49.2.0.10062
ASN.1 notation

{1 3 6 1 4 1 62698 2 49 2 0 10062}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) fsas-technologies(62698) sniProductMibs-2(2) fscRAIDMIB-2(49) svrNotifications-2(2) 0 svrTrapLDConCheckFailed-2(10062)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) fsas-technologies(62698) sniProductMibs-2(2) fscRAIDMIB-2(49) svrNotifications-2(2) 0 svrTrapLDConCheckFailed-2(10062)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) fsas-technologies(62698) sniProductMibs-2(2) fscRAIDMIB-2(49) svrNotifications-2(2) 0 svrTrapLDConCheckFailed-2(10062)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) fsas-technologies(62698) sniProductMibs-2(2) fscRAIDMIB-2(49) svrNotifications-2(2) 0 svrTrapLDConCheckFailed-2(10062)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) fsas-technologies(62698) sniProductMibs-2(2) fscRAIDMIB-2(49) svrNotifications-2(2) 0 svrTrapLDConCheckFailed-2(10062)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) fsas-technologies(62698) sniProductMibs-2(2) fscRAIDMIB-2(49) svrNotifications-2(2) 0 svrTrapLDConCheckFailed-2(10062)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) fsas-technologies(62698) sniProductMibs-2(2) fscRAIDMIB-2(49) svrNotifications-2(2) 0 svrTrapLDConCheckFailed-2(10062)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) fsas-technologies(62698) sniProductMibs-2(2) fscRAIDMIB-2(49) svrNotifications-2(2) 0 svrTrapLDConCheckFailed-2(10062)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) fsas-technologies(62698) sniProductMibs-2(2) fscRAIDMIB-2(49) svrNotifications-2(2) 0 svrTrapLDConCheckFailed-2(10062)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) fsas-technologies(62698) sniProductMibs-2(2) fscRAIDMIB-2(49) svrNotifications-2(2) 0 svrTrapLDConCheckFailed-2(10062)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) fsas-technologies(62698) sniProductMibs-2(2) fscRAIDMIB-2(49) svrNotifications-2(2) 0 svrTrapLDConCheckFailed-2(10062)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) fsas-technologies(62698) sniProductMibs-2(2) fscRAIDMIB-2(49) svrNotifications-2(2) 0 svrTrapLDConCheckFailed-2(10062)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) fsas-technologies(62698) sniProductMibs-2(2) fscRAIDMIB-2(49) svrNotifications-2(2) 0 svrTrapLDConCheckFailed-2(10062)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) fsas-technologies(62698) sniProductMibs-2(2) fscRAIDMIB-2(49) svrNotifications-2(2) 0 svrTrapLDConCheckFailed-2(10062)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) fsas-technologies(62698) sniProductMibs-2(2) fscRAIDMIB-2(49) svrNotifications-2(2) 0 svrTrapLDConCheckFailed-2(10062)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) fsas-technologies(62698) sniProductMibs-2(2) fscRAIDMIB-2(49) svrNotifications-2(2) 0 svrTrapLDConCheckFailed-2(10062)}
OID-IRI notation
  • /1/3/6/1/4/1/62698/2/49/2/0/10062
  • /ISO/Identified-Organization/6/1/4/1/62698/2/49/2/0/10062
  • /ISO/3/6/1/4/1/62698/2/49/2/0/10062
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/fsas-technologies/sniProductMibs-2/fscRAIDMIB-2/svrNotifications-2/0/svrTrapLDConCheckFailed-2
  • /iso/identified-organization/dod/internet/private/enterprises/fsas-technologies/sniProductMibs-2/fscRAIDMIB-2/svrNotifications-2/0/svrTrapLDConCheckFailed-2
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/fsas-technologies/sniProductMibs-2/fscRAIDMIB-2/svrNotifications-2/0/svrTrapLDConCheckFailed-2
  • /iso/identified-organization/dod/internet/private/vendor-objects/fsas-technologies/sniProductMibs-2/fscRAIDMIB-2/svrNotifications-2/0/svrTrapLDConCheckFailed-2
  • /iso/org/dod/internet/private/enterprise/fsas-technologies/sniProductMibs-2/fscRAIDMIB-2/svrNotifications-2/0/svrTrapLDConCheckFailed-2
  • /iso/org/dod/internet/private/enterprises/fsas-technologies/sniProductMibs-2/fscRAIDMIB-2/svrNotifications-2/0/svrTrapLDConCheckFailed-2
  • /iso/org/dod/internet/private/ldap-enterprise/fsas-technologies/sniProductMibs-2/fscRAIDMIB-2/svrNotifications-2/0/svrTrapLDConCheckFailed-2
  • /iso/org/dod/internet/private/vendor-objects/fsas-technologies/sniProductMibs-2/fscRAIDMIB-2/svrNotifications-2/0/svrTrapLDConCheckFailed-2
  • /iso/iso-identified-organization/dod/internet/private/enterprise/fsas-technologies/sniProductMibs-2/fscRAIDMIB-2/svrNotifications-2/0/svrTrapLDConCheckFailed-2
  • /iso/iso-identified-organization/dod/internet/private/enterprises/fsas-technologies/sniProductMibs-2/fscRAIDMIB-2/svrNotifications-2/0/svrTrapLDConCheckFailed-2
  • /iso/iso-identified-organization/dod/internet/private/ldap-enterprise/fsas-technologies/sniProductMibs-2/fscRAIDMIB-2/svrNotifications-2/0/svrTrapLDConCheckFailed-2
  • /iso/iso-identified-organization/dod/internet/private/vendor-objects/fsas-technologies/sniProductMibs-2/fscRAIDMIB-2/svrNotifications-2/0/svrTrapLDConCheckFailed-2
  • /iso/iso-organization/dod/internet/private/enterprise/fsas-technologies/sniProductMibs-2/fscRAIDMIB-2/svrNotifications-2/0/svrTrapLDConCheckFailed-2
  • /iso/iso-organization/dod/internet/private/enterprises/fsas-technologies/sniProductMibs-2/fscRAIDMIB-2/svrNotifications-2/0/svrTrapLDConCheckFailed-2
  • /iso/iso-organization/dod/internet/private/ldap-enterprise/fsas-technologies/sniProductMibs-2/fscRAIDMIB-2/svrNotifications-2/0/svrTrapLDConCheckFailed-2
  • /iso/iso-organization/dod/internet/private/vendor-objects/fsas-technologies/sniProductMibs-2/fscRAIDMIB-2/svrNotifications-2/0/svrTrapLDConCheckFailed-2

Descriptions

svrTrapLDConCheckFailed-2 — Fujitsu and Fsas ServerView RAID MIBs (official package)

Consistency check failed on logical drive.

Source records

svrTrapLDConCheckFailed-2

Status in source: unspecified.

Names: svrTrapLDConCheckFailed-2

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "svrTrapLDConCheckFailed-2",
    "TRAP-TYPE",
    "ENTERPRISE",
    "svrNotifications-2",
    "VARIABLES",
    "{",
    "svrTrapInfoServerName-2",
    ",",
    "svrTrapInfoTime-2",
    ",",
    "svrTrapInfoPlaceHolder1-2",
    ",",
    "svrTrapInfoPlaceHolder2-2",
    ",",
    "svrTrapInfoPlaceHolder3-2",
    ",",
    "svrTrapInfoPlaceHolder4-2",
    ",",
    "svrTrapInfoPlaceHolder5-2",
    ",",
    "svrTrapInfoPlaceHolder6-2",
    "}",
    "DESCRIPTION",
    "\"Consistency check failed on logical drive.\"",
    "::=",
    "10062"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "svrNotifications-2"
      ]
    ],
    [
      "VarTypes",
      [
        "svrTrapInfoServerName-2",
        "svrTrapInfoTime-2",
        "svrTrapInfoPlaceHolder1-2",
        "svrTrapInfoPlaceHolder2-2",
        "svrTrapInfoPlaceHolder3-2",
        "svrTrapInfoPlaceHolder4-2",
        "svrTrapInfoPlaceHolder5-2",
        "svrTrapInfoPlaceHolder6-2"
      ]
    ],
    [
      "DESCRIPTION",
      "Consistency check failed on logical drive."
    ],
    null
  ]
}
  • Fujitsu and Fsas ServerView RAID MIBs (official package) · Publisher's source file: Source package: SNMPMIBs.zip

    Module: FSC-RAID-MIB-2

    Published definition
    svrTrapLDConCheckFailed-2 TRAP-TYPE
        ENTERPRISE svrNotifications-2
        VARIABLES {
            svrTrapInfoServerName-2,
            svrTrapInfoTime-2,
            svrTrapInfoPlaceHolder1-2,
            svrTrapInfoPlaceHolder2-2,
            svrTrapInfoPlaceHolder3-2,
            svrTrapInfoPlaceHolder4-2,
            svrTrapInfoPlaceHolder5-2,
            svrTrapInfoPlaceHolder6-2
            }
        DESCRIPTION     "Consistency check failed on logical drive."
        --#TYPE            "Consistency check failed on logical drive"
        --#SUMMARY         "Adapter %s: Consistency check failed on logical drive %s (Server %s)"
        --#ARGUMENTS       { 2, 3, 0 }
        --#SEVERITY        MAJOR
        --#TIMEINDEX       1
        --#HELP            "Failure happens only if a disk out of the logical drive failed. 1) Check state of logical drive. 2) If logical drive is not operational, check state of affected disk. 3) Check for additional error messages for affected disk."
        --#STATE           OPERATIONAL
        ::= 10062
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['Counter', 'Gauge', 'enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download Fujitsu RAID MIB — RAID-2.mib

    Related source files and packages:


    Source location: FSC-RAID-MIB-2::svrTrapLDConCheckFailed-2.
    Source version and references

    ServerView RAID Manager MIB distributed in the official Fujitsu package. This edition uses the Fsas Technologies enterprise number 62698.; Publisher path: prim_supportcd/SVSSoftware/Software/ServerView/MIBs/SNMPMIBs.zip; 1.2 MiB

    Downloaded: 2026-11-03T05:39:26.355194+00:00.

Current Registration Authority (inferred from ancestor 1.3.6.1.4.1.62698)

Fsas Technologies Inc.

Siblings (1446)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.62698.2.49.2.0.10146 svrTrapLDWriteModeWriteBack-200
1.3.6.1.4.1.62698.2.49.2.0.10147 svrTrapLSIOModeDirect-200
1.3.6.1.4.1.62698.2.49.2.0.10148 svrTrapLSIOModeCached-200
1.3.6.1.4.1.62698.2.49.2.0.10149 svrTrapPDTransferSpeedChanged-200
1.3.6.1.4.1.62698.2.49.2.0.10150 svrTrapPDBusWidthChanged-200
1.3.6.1.4.1.62698.2.49.2.0.10151 svrTrapBBUVoltageProblemDetected-200
1.3.6.1.4.1.62698.2.49.2.0.10152 svrTrapBBUTempProblemDetected-200
1.3.6.1.4.1.62698.2.49.2.0.10153 svrTrapBBUCharging-200
1.3.6.1.4.1.62698.2.49.2.0.10154 svrTrapBBUFailed-200
1.3.6.1.4.1.62698.2.49.2.0.10155 svrTrapBBUNormal-200
1.3.6.1.4.1.62698.2.49.2.0.10156 svrTrapBBUDischarging-200
1.3.6.1.4.1.62698.2.49.2.0.10157 svrTrapAdapterDiskErrorFixed-200
1.3.6.1.4.1.62698.2.49.2.0.10158 svrTrapAdapterDriverWriteCacheEnabled-200
1.3.6.1.4.1.62698.2.49.2.0.10159 svrTrapAdapterDriverWriteCacheDisabled-200
1.3.6.1.4.1.62698.2.49.2.0.10160 svrTrapAdapterDriveSizingEnabled-200
1.3.6.1.4.1.62698.2.49.2.0.10161 svrTrapAdapterDriveSizingDisabled-200
1.3.6.1.4.1.62698.2.49.2.0.10162 svrTrapAdapterHotspareAndAutomaticRebuildEnabled-200
1.3.6.1.4.1.62698.2.49.2.0.10163 svrTrapAdapterHotspareAndAutomaticRebuildDisabled-200
1.3.6.1.4.1.62698.2.49.2.0.10164 svrTrapAdapterTaskRateChanged-200
1.3.6.1.4.1.62698.2.49.2.0.10165 svrTrapAdapterInonHandlingCheck-200
1.3.6.1.4.1.62698.2.49.2.0.10166 svrTrapAdapterInonHandlingCheckAbort-200
1.3.6.1.4.1.62698.2.49.2.0.10167 svrTrapAdapterInonHandlingMDC-200
1.3.6.1.4.1.62698.2.49.2.0.10168 svrTrapLDNameChanged-200
1.3.6.1.4.1.62698.2.49.2.0.10169 svrTrapLDCacheWriteModeChanged-200
1.3.6.1.4.1.62698.2.49.2.0.10170 svrTrapRebootRequired-200
1.3.6.1.4.1.62698.2.49.2.0.10171 svrTrapModuleLoggedIn-200
1.3.6.1.4.1.62698.2.49.2.0.10172 svrTrapModuleLoggedOut-200
1.3.6.1.4.1.62698.2.49.2.0.10173 svrTrapAdapterHotspareEnabled-200
1.3.6.1.4.1.62698.2.49.2.0.10174 svrTrapAdapterHotspareDisabled-200
1.3.6.1.4.1.62698.2.49.2.0.10175 svrTrapAdapterHotswapEnabled-200
1.3.6.1.4.1.62698.2.49.2.0.10176 svrTrapAdapterHotswapDisabled-200
1.3.6.1.4.1.62698.2.49.2.0.10177 svrTrapAdapterWriteModeWriteBack-200
1.3.6.1.4.1.62698.2.49.2.0.10178 svrTrapAdapterWriteModeWriteThrough-200
1.3.6.1.4.1.62698.2.49.2.0.10179 svrTrapAdapterWriteModeAdaptive-200
1.3.6.1.4.1.62698.2.49.2.0.10180 svrTrapBatteryChargeStarted-200
1.3.6.1.4.1.62698.2.49.2.0.10181 svrTrapAdapterAutomaticRAID5InitEnabled-200
1.3.6.1.4.1.62698.2.49.2.0.10182 svrTrapAdapterAutomaticRAID5InitDisabled-200
1.3.6.1.4.1.62698.2.49.2.0.10183 svrTrapAdapterCopyBackEnabled-200
1.3.6.1.4.1.62698.2.49.2.0.10184 svrTrapAdapterCopyBackDisabled-200
1.3.6.1.4.1.62698.2.49.2.0.10185 svrTrapAdapterInitClear-200
1.3.6.1.4.1.62698.2.49.2.0.10186 svrTrapPDVerifyStarted-200
1.3.6.1.4.1.62698.2.49.2.0.10187 svrTrapPDVerifyFinished-200
1.3.6.1.4.1.62698.2.49.2.0.10188 svrTrapLDReadModeChanged-200
1.3.6.1.4.1.62698.2.49.2.0.10189 svrTrapLDCacheModeChanged-200
1.3.6.1.4.1.62698.2.49.2.0.10190 svrTrapLDAcessModeChanged-200
1.3.6.1.4.1.62698.2.49.2.0.10191 svrTrapLDBGIModeChanged-200
1.3.6.1.4.1.62698.2.49.2.0.10192 svrTrapLDDiskCacheModeChanged-200
1.3.6.1.4.1.62698.2.49.2.0.10193 svrTrapBoot-200
1.3.6.1.4.1.62698.2.49.2.0.10194 svrTrapVersion-200
1.3.6.1.4.1.62698.2.49.2.0.10195 svrTrapBBUTBBUDirtyCacheConfigMismatch-200