OID reference

nbsSffWdmMaxCaseTemperature

1.3.6.1.4.1.629.204.1.2.1.1.5

Description

This field defines the maximum operating case temperature in Celsius. For WDMs, this value is in byte 15 in A0h, For XFPs, this value is in byte 190.

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.629.204.1.2.1.1 (nbsSffWdmEntry)
Node code
5
Node name
nbsSffWdmMaxCaseTemperature
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.629.204.1.2.1.1.5
URN notation
urn:oid:1.3.6.1.4.1.629.204.1.2.1.1.5
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 629 204 1 2 1 1 5}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nbase(629) nbsSffMib(204) nbsSffObjects(1) nbsSffWdmGrp(2) nbsSffWdmTable(1) nbsSffWdmEntry(1) nbsSffWdmMaxCaseTemperature(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nbs(629) nbsSffMib(204) nbsSffObjects(1) nbsSffWdmGrp(2) nbsSffWdmTable(1) nbsSffWdmEntry(1) nbsSffWdmMaxCaseTemperature(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nbase(629) nbsSffMib(204) nbsSffObjects(1) nbsSffWdmGrp(2) nbsSffWdmTable(1) nbsSffWdmEntry(1) nbsSffWdmMaxCaseTemperature(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nbs(629) nbsSffMib(204) nbsSffObjects(1) nbsSffWdmGrp(2) nbsSffWdmTable(1) nbsSffWdmEntry(1) nbsSffWdmMaxCaseTemperature(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nbase(629) nbsSffMib(204) nbsSffObjects(1) nbsSffWdmGrp(2) nbsSffWdmTable(1) nbsSffWdmEntry(1) nbsSffWdmMaxCaseTemperature(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nbs(629) nbsSffMib(204) nbsSffObjects(1) nbsSffWdmGrp(2) nbsSffWdmTable(1) nbsSffWdmEntry(1) nbsSffWdmMaxCaseTemperature(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nbase(629) nbsSffMib(204) nbsSffObjects(1) nbsSffWdmGrp(2) nbsSffWdmTable(1) nbsSffWdmEntry(1) nbsSffWdmMaxCaseTemperature(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nbs(629) nbsSffMib(204) nbsSffObjects(1) nbsSffWdmGrp(2) nbsSffWdmTable(1) nbsSffWdmEntry(1) nbsSffWdmMaxCaseTemperature(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) nbase(629) nbsSffMib(204) nbsSffObjects(1) nbsSffWdmGrp(2) nbsSffWdmTable(1) nbsSffWdmEntry(1) nbsSffWdmMaxCaseTemperature(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) nbs(629) nbsSffMib(204) nbsSffObjects(1) nbsSffWdmGrp(2) nbsSffWdmTable(1) nbsSffWdmEntry(1) nbsSffWdmMaxCaseTemperature(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) nbase(629) nbsSffMib(204) nbsSffObjects(1) nbsSffWdmGrp(2) nbsSffWdmTable(1) nbsSffWdmEntry(1) nbsSffWdmMaxCaseTemperature(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) nbs(629) nbsSffMib(204) nbsSffObjects(1) nbsSffWdmGrp(2) nbsSffWdmTable(1) nbsSffWdmEntry(1) nbsSffWdmMaxCaseTemperature(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) nbase(629) nbsSffMib(204) nbsSffObjects(1) nbsSffWdmGrp(2) nbsSffWdmTable(1) nbsSffWdmEntry(1) nbsSffWdmMaxCaseTemperature(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) nbs(629) nbsSffMib(204) nbsSffObjects(1) nbsSffWdmGrp(2) nbsSffWdmTable(1) nbsSffWdmEntry(1) nbsSffWdmMaxCaseTemperature(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) nbase(629) nbsSffMib(204) nbsSffObjects(1) nbsSffWdmGrp(2) nbsSffWdmTable(1) nbsSffWdmEntry(1) nbsSffWdmMaxCaseTemperature(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) nbs(629) nbsSffMib(204) nbsSffObjects(1) nbsSffWdmGrp(2) nbsSffWdmTable(1) nbsSffWdmEntry(1) nbsSffWdmMaxCaseTemperature(5)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/629/204/1/2/1/1/5
  • /ISO/Identified-Organization/6/1/4/1/629/204/1/2/1/1/5
  • /ISO/3/6/1/4/1/629/204/1/2/1/1/5
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/nbase/nbsSffMib/nbsSffObjects/nbsSffWdmGrp/nbsSffWdmTable/nbsSffWdmEntry/nbsSffWdmMaxCaseTemperature
  • /iso/identified-organization/dod/internet/private/enterprise/nbs/nbsSffMib/nbsSffObjects/nbsSffWdmGrp/nbsSffWdmTable/nbsSffWdmEntry/nbsSffWdmMaxCaseTemperature
  • /iso/identified-organization/dod/internet/private/enterprises/nbase/nbsSffMib/nbsSffObjects/nbsSffWdmGrp/nbsSffWdmTable/nbsSffWdmEntry/nbsSffWdmMaxCaseTemperature
  • /iso/identified-organization/dod/internet/private/enterprises/nbs/nbsSffMib/nbsSffObjects/nbsSffWdmGrp/nbsSffWdmTable/nbsSffWdmEntry/nbsSffWdmMaxCaseTemperature
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/nbase/nbsSffMib/nbsSffObjects/nbsSffWdmGrp/nbsSffWdmTable/nbsSffWdmEntry/nbsSffWdmMaxCaseTemperature
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/nbs/nbsSffMib/nbsSffObjects/nbsSffWdmGrp/nbsSffWdmTable/nbsSffWdmEntry/nbsSffWdmMaxCaseTemperature
  • /iso/identified-organization/dod/internet/private/vendor-objects/nbase/nbsSffMib/nbsSffObjects/nbsSffWdmGrp/nbsSffWdmTable/nbsSffWdmEntry/nbsSffWdmMaxCaseTemperature
  • /iso/identified-organization/dod/internet/private/vendor-objects/nbs/nbsSffMib/nbsSffObjects/nbsSffWdmGrp/nbsSffWdmTable/nbsSffWdmEntry/nbsSffWdmMaxCaseTemperature
  • /iso/org/dod/internet/private/enterprise/nbase/nbsSffMib/nbsSffObjects/nbsSffWdmGrp/nbsSffWdmTable/nbsSffWdmEntry/nbsSffWdmMaxCaseTemperature
  • /iso/org/dod/internet/private/enterprise/nbs/nbsSffMib/nbsSffObjects/nbsSffWdmGrp/nbsSffWdmTable/nbsSffWdmEntry/nbsSffWdmMaxCaseTemperature
  • /iso/org/dod/internet/private/enterprises/nbase/nbsSffMib/nbsSffObjects/nbsSffWdmGrp/nbsSffWdmTable/nbsSffWdmEntry/nbsSffWdmMaxCaseTemperature
  • /iso/org/dod/internet/private/enterprises/nbs/nbsSffMib/nbsSffObjects/nbsSffWdmGrp/nbsSffWdmTable/nbsSffWdmEntry/nbsSffWdmMaxCaseTemperature
  • /iso/org/dod/internet/private/ldap-enterprise/nbase/nbsSffMib/nbsSffObjects/nbsSffWdmGrp/nbsSffWdmTable/nbsSffWdmEntry/nbsSffWdmMaxCaseTemperature
  • /iso/org/dod/internet/private/ldap-enterprise/nbs/nbsSffMib/nbsSffObjects/nbsSffWdmGrp/nbsSffWdmTable/nbsSffWdmEntry/nbsSffWdmMaxCaseTemperature
  • /iso/org/dod/internet/private/vendor-objects/nbase/nbsSffMib/nbsSffObjects/nbsSffWdmGrp/nbsSffWdmTable/nbsSffWdmEntry/nbsSffWdmMaxCaseTemperature
  • /iso/org/dod/internet/private/vendor-objects/nbs/nbsSffMib/nbsSffObjects/nbsSffWdmGrp/nbsSffWdmTable/nbsSffWdmEntry/nbsSffWdmMaxCaseTemperature
  • Additional combinations skipped.

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-only
Status in MIB
current
Default value
70
Allowed ranges
-2147483647–2147483647

Using this OID with SNMP

At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition. The index encoding is not inferred here.

Published row index: nbsSffMsaPhysicalIfIndex.

snmpwalk [connection options] DEVICE .1.3.6.1.4.1.629.204.1.2.1.1.5

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

The displayed source records contain one distinct definition. Compare its source records.

nbsSffWdmMaxCaseTemperature OBJECT-TYPE
    SYNTAX      INTEGER (-2147483647..2147483647)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This field defines the maximum operating case temperature in
         Celsius. For WDMs, this value is in byte 15 in A0h, For XFPs,
         this value is in byte 190."
    REFERENCE   "Specification for DWDM SFP Transceiver, section 2.2.9
                and Specification for XFP MSA, INF8077i section 5.35"
    DEFVAL { 70 }
    ::= { nbsSffWdmEntry 5 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

This field defines the maximum operating case temperature in Celsius. For WDMs, this value is in byte 15 in A0h, For XFPs, this value is in byte 190.

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 1

nbsSffWdmMaxCaseTemperature · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: nbsSffWdmMaxCaseTemperature

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "nbsSffWdmMaxCaseTemperature",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "(",
    "-",
    "2147483647",
    ".",
    ".",
    "2147483647",
    ")",
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"This field defines the maximum operating case temperature in Celsius. For WDMs, this value is in byte 15 in A0h, For XFPs, this value is in byte 190.\"",
    "REFERENCE",
    "\"Specification for DWDM SFP Transceiver, section 2.2.9 and Specification for XFP MSA, INF8077i section 5.35\"",
    "DEFVAL",
    "{",
    "70",
    "}",
    "::=",
    "{",
    "nbsSffWdmEntry",
    "5",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "integerSubType",
        [
          [
            -2147483647,
            2147483647
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "This field defines the maximum operating case temperature in Celsius. For WDMs, this value is in byte 15 in A0h, For XFPs, this value is in byte 190."
    ],
    [
      "REFERENCE",
      "Specification for DWDM SFP Transceiver, section 2.2.9 and Specification for XFP MSA, INF8077i section 5.35"
    ],
    null,
    null,
    [
      "DEFVAL",
      70
    ]
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.629)

Rotenstein Sergiu

Siblings (18)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.629.204.1.2.1.1.1 nbsSffWdmClassOfPower00
1.3.6.1.4.1.629.204.1.2.1.1.2 nbsSffWdmClassOfTemperature00
1.3.6.1.4.1.629.204.1.2.1.1.3 nbsSffWdmClassOfWdm00
1.3.6.1.4.1.629.204.1.2.1.1.4 nbsSffWdmOpticalReach00
1.3.6.1.4.1.629.204.1.2.1.1.6 nbsSffWdmMinCaseTemperature00
1.3.6.1.4.1.629.204.1.2.1.1.7 nbsSffWdmMaxSupplyCurrent00
1.3.6.1.4.1.629.204.1.2.1.1.8 nbsSffWdmNumberOfChannels00
1.3.6.1.4.1.629.204.1.2.1.1.9 nbsSffWdmChannelSpacing00
1.3.6.1.4.1.629.204.1.2.1.1.10 nbsSffWdmVariableDecisionThreshold00
1.3.6.1.4.1.629.204.1.2.1.1.11 nbsSffWdmWavelengthMonitorType00
1.3.6.1.4.1.629.204.1.2.1.1.12 nbsSffWdmExtTransmitPowerType00
1.3.6.1.4.1.629.204.1.2.1.1.13 nbsSffWdmVariableOpticalAttenuator00
1.3.6.1.4.1.629.204.1.2.1.1.14 nbsSffWdmPilotToneFunctionality00
1.3.6.1.4.1.629.204.1.2.1.1.15 nbsSffWdmOptionalInterruptPin00
1.3.6.1.4.1.629.204.1.2.1.1.16 nbsSffWdmLaserWavelength00
1.3.6.1.4.1.629.204.1.2.1.1.17 nbsSffWdmFrequency00
1.3.6.1.4.1.629.204.1.2.1.1.18 nbsSffWdmChannelBand00
1.3.6.1.4.1.629.204.1.2.1.1.19 nbsSffWdmChannelNumber00