Indicates the hold-off time for verifying local SF The hold-off time's step must be 100
Sources for this description
DASAN Networks MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.6296.101.4.12.2.2.36
Indicates the hold-off time for verifying local SF The hold-off time's step must be 100
Identification
{1 3 6 1 4 1 6296 101 4 12 2 2 36}
At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.
snmpget [connection options] DEVICE .1.3.6.1.4.1.6296.101.4.12.2.2.36.0
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
sleY1731MegControlRapsHoldOffTime OBJECT-TYPE
SYNTAX Integer32 (0..10000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the hold-off time for verifying local SF
The hold-off time's step must be 100
"
::= { sleY1731MegControl 36 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Indicates the hold-off time for verifying local SF The hold-off time's step must be 100
DASAN Networks MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: sleY1731MegControlRapsHoldOffTime
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"sleY1731MegControlRapsHoldOffTime",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"(",
"0",
".",
".",
"10000",
")",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"Indicates the hold-off time for verifying local SF The hold-off time's step must be 100 \"",
"::=",
"{",
"sleY1731MegControl",
"36",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32",
[
"integerSubType",
[
[
0,
10000
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Indicates the hold-off time for verifying local SF The hold-off time's step must be 100"
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive. DASAN Networks support.
Module: SLE-FAULTMGMT-MIB
See published definition above
{'DASAN-SMI': ['sleMgmt'], 'SNMPv2-TC': ['MacAddress', 'TimeStamp', 'TEXTUAL-CONVENTION'], 'SLE-TC-MIB': ['SleControlStatusType', 'SleControlRequestResultType'], 'SNMPv2-SMI': ['TimeTicks', 'IpAddress', 'Integer32', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'BITS', 'OBJECT-TYPE', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'NOTIFICATION-GROUP']}Related source files and packages:
Same file in Observium Community.
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.6296.101.4.12.2.2.1 | sleY1731MegControlRequest | 0 | 0 | |
| 1.3.6.1.4.1.6296.101.4.12.2.2.2 | sleY1731MegControlStatus | 0 | 0 | |
| 1.3.6.1.4.1.6296.101.4.12.2.2.3 | sleY1731MegControlTimer | 0 | 0 | |
| 1.3.6.1.4.1.6296.101.4.12.2.2.4 | sleY1731MegControlTimeStamp | 0 | 0 | |
| 1.3.6.1.4.1.6296.101.4.12.2.2.5 | sleY1731MegControlReqResult | 0 | 0 | |
| 1.3.6.1.4.1.6296.101.4.12.2.2.6 | sleY1731MegControlIndex | 0 | 0 | |
| 1.3.6.1.4.1.6296.101.4.12.2.2.7 | sleY1731MegControlName | 0 | 0 | |
| 1.3.6.1.4.1.6296.101.4.12.2.2.8 | sleY1731MegControlLevel | 0 | 0 | |
| 1.3.6.1.4.1.6296.101.4.12.2.2.9 | sleY1731MegControlVid | 0 | 0 | |
| 1.3.6.1.4.1.6296.101.4.12.2.2.10 | sleY1731MegControlMepEnable | 0 | 0 | |
| 1.3.6.1.4.1.6296.101.4.12.2.2.11 | sleY1731MegControlCcEnable | 0 | 0 | |
| 1.3.6.1.4.1.6296.101.4.12.2.2.12 | sleY1731MegControlCcInterval | 0 | 0 | |
| 1.3.6.1.4.1.6296.101.4.12.2.2.13 | sleY1731MegControlCcPriority | 0 | 0 | |
| 1.3.6.1.4.1.6296.101.4.12.2.2.14 | sleY1731MegControlCcLossThreshold | 0 | 0 | |
| 1.3.6.1.4.1.6296.101.4.12.2.2.15 | sleY1731MegControlCcHoldTime | 0 | 0 | |
| 1.3.6.1.4.1.6296.101.4.12.2.2.16 | sleY1731MegControlFaultPriority | 0 | 0 | |
| 1.3.6.1.4.1.6296.101.4.12.2.2.17 | sleY1731MegControlFaultKeepTime | 0 | 0 | |
| 1.3.6.1.4.1.6296.101.4.12.2.2.18 | sleY1731MegControlFaultClearTime | 0 | 0 | |
| 1.3.6.1.4.1.6296.101.4.12.2.2.19 | sleY1731MegControlXcheckEnable | 0 | 0 | |
| 1.3.6.1.4.1.6296.101.4.12.2.2.20 | sleY1731MegControlAisEnable | 0 | 0 | |
| 1.3.6.1.4.1.6296.101.4.12.2.2.21 | sleY1731MegControlAisTransmitEnable | 0 | 0 | |
| 1.3.6.1.4.1.6296.101.4.12.2.2.22 | sleY1731MegControlAisInterval | 0 | 0 | |
| 1.3.6.1.4.1.6296.101.4.12.2.2.23 | sleY1731MegControlAisLevel | 0 | 0 | |
| 1.3.6.1.4.1.6296.101.4.12.2.2.24 | sleY1731MegControlAisPriority | 0 | 0 | |
| 1.3.6.1.4.1.6296.101.4.12.2.2.25 | sleY1731MegControlLckEnable | 0 | 0 | |
| 1.3.6.1.4.1.6296.101.4.12.2.2.26 | sleY1731MegControlLckTransmitEnable | 0 | 0 | |
| 1.3.6.1.4.1.6296.101.4.12.2.2.27 | sleY1731MegControlLckInterval | 0 | 0 | |
| 1.3.6.1.4.1.6296.101.4.12.2.2.28 | sleY1731MegControlLckLevel | 0 | 0 | |
| 1.3.6.1.4.1.6296.101.4.12.2.2.29 | sleY1731MegControlLckPriority | 0 | 0 | |
| 1.3.6.1.4.1.6296.101.4.12.2.2.30 | sleY1731MegControlOutOfService | 0 | 0 | |
| 1.3.6.1.4.1.6296.101.4.12.2.2.31 | sleY1731MegControlRapsEnable | 0 | 0 | |
| 1.3.6.1.4.1.6296.101.4.12.2.2.32 | sleY1731MegControlRapsRplOwner | 0 | 0 | |
| 1.3.6.1.4.1.6296.101.4.12.2.2.33 | sleY1731MegControlRapsEastPort | 0 | 0 | |
| 1.3.6.1.4.1.6296.101.4.12.2.2.34 | sleY1731MegControlRapsWestPort | 0 | 0 | |
| 1.3.6.1.4.1.6296.101.4.12.2.2.35 | sleY1731MegControlRapsRplPort | 0 | 0 | |
| 1.3.6.1.4.1.6296.101.4.12.2.2.37 | sleY1731MegControlRapsGuardTime | 0 | 0 | |
| 1.3.6.1.4.1.6296.101.4.12.2.2.38 | sleY1731MegControlRapsWaitToRestore | 0 | 0 | |
| 1.3.6.1.4.1.6296.101.4.12.2.2.39 | sleY1731MegControlRapsNonRevertive | 0 | 0 | |
| 1.3.6.1.4.1.6296.101.4.12.2.2.40 | sleY1731MegControlRapsForcedSwitchEast | 0 | 0 | |
| 1.3.6.1.4.1.6296.101.4.12.2.2.41 | sleY1731MegControlRapsForcedSwitchWest | 0 | 0 | |
| 1.3.6.1.4.1.6296.101.4.12.2.2.42 | sleY1731MegControlMd | 0 | 0 |