OID reference

sleAlarmVariable

1.3.6.1.4.1.6296.101.9.2.1.1.3

Description

The object identifier of the particular variable to be sampled. Only variables that resolve to an ASN.1 primitive type of INTEGER (INTEGER, Counter, Gauge, or TimeTicks) may be sampled. Because SNMP access control is articulated entirely in terms of the contents of MIB views, no access control mechanism exists that ca…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.6296.101.9.2.1.1 (sleAlarmEntry)
Node code
3
Node name
sleAlarmVariable
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.6296.101.9.2.1.1.3
URN notation
urn:oid:1.3.6.1.4.1.6296.101.9.2.1.1.3
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 6296 101 9 2 1 1 3}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) dasan(6296) sleMgmt(101) sleRmon(9) sleAlarm(2) sleAlarmTable(1) sleAlarmEntry(1) sleAlarmVariable(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) dasan(6296) sleMgmt(101) sleRmon(9) sleAlarm(2) sleAlarmTable(1) sleAlarmEntry(1) sleAlarmVariable(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) dasan(6296) sleMgmt(101) sleRmon(9) sleAlarm(2) sleAlarmTable(1) sleAlarmEntry(1) sleAlarmVariable(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) dasan(6296) sleMgmt(101) sleRmon(9) sleAlarm(2) sleAlarmTable(1) sleAlarmEntry(1) sleAlarmVariable(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) dasan(6296) sleMgmt(101) sleRmon(9) sleAlarm(2) sleAlarmTable(1) sleAlarmEntry(1) sleAlarmVariable(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) dasan(6296) sleMgmt(101) sleRmon(9) sleAlarm(2) sleAlarmTable(1) sleAlarmEntry(1) sleAlarmVariable(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) dasan(6296) sleMgmt(101) sleRmon(9) sleAlarm(2) sleAlarmTable(1) sleAlarmEntry(1) sleAlarmVariable(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) dasan(6296) sleMgmt(101) sleRmon(9) sleAlarm(2) sleAlarmTable(1) sleAlarmEntry(1) sleAlarmVariable(3)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) dasan(6296) sleMgmt(101) sleRmon(9) sleAlarm(2) sleAlarmTable(1) sleAlarmEntry(1) sleAlarmVariable(3)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) dasan(6296) sleMgmt(101) sleRmon(9) sleAlarm(2) sleAlarmTable(1) sleAlarmEntry(1) sleAlarmVariable(3)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) dasan(6296) sleMgmt(101) sleRmon(9) sleAlarm(2) sleAlarmTable(1) sleAlarmEntry(1) sleAlarmVariable(3)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) dasan(6296) sleMgmt(101) sleRmon(9) sleAlarm(2) sleAlarmTable(1) sleAlarmEntry(1) sleAlarmVariable(3)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) dasan(6296) sleMgmt(101) sleRmon(9) sleAlarm(2) sleAlarmTable(1) sleAlarmEntry(1) sleAlarmVariable(3)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) dasan(6296) sleMgmt(101) sleRmon(9) sleAlarm(2) sleAlarmTable(1) sleAlarmEntry(1) sleAlarmVariable(3)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) dasan(6296) sleMgmt(101) sleRmon(9) sleAlarm(2) sleAlarmTable(1) sleAlarmEntry(1) sleAlarmVariable(3)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) dasan(6296) sleMgmt(101) sleRmon(9) sleAlarm(2) sleAlarmTable(1) sleAlarmEntry(1) sleAlarmVariable(3)}
OID-IRI notation
  • /1/3/6/1/4/1/6296/101/9/2/1/1/3
  • /ISO/Identified-Organization/6/1/4/1/6296/101/9/2/1/1/3
  • /ISO/3/6/1/4/1/6296/101/9/2/1/1/3
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/6296/sleMgmt/sleRmon/sleAlarm/sleAlarmTable/sleAlarmEntry/sleAlarmVariable
  • /iso/identified-organization/dod/internet/private/enterprise/dasan/sleMgmt/sleRmon/sleAlarm/sleAlarmTable/sleAlarmEntry/sleAlarmVariable
  • /iso/identified-organization/dod/internet/private/enterprises/6296/sleMgmt/sleRmon/sleAlarm/sleAlarmTable/sleAlarmEntry/sleAlarmVariable
  • /iso/identified-organization/dod/internet/private/enterprises/dasan/sleMgmt/sleRmon/sleAlarm/sleAlarmTable/sleAlarmEntry/sleAlarmVariable
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/6296/sleMgmt/sleRmon/sleAlarm/sleAlarmTable/sleAlarmEntry/sleAlarmVariable
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/dasan/sleMgmt/sleRmon/sleAlarm/sleAlarmTable/sleAlarmEntry/sleAlarmVariable
  • /iso/identified-organization/dod/internet/private/vendor-objects/6296/sleMgmt/sleRmon/sleAlarm/sleAlarmTable/sleAlarmEntry/sleAlarmVariable
  • /iso/identified-organization/dod/internet/private/vendor-objects/dasan/sleMgmt/sleRmon/sleAlarm/sleAlarmTable/sleAlarmEntry/sleAlarmVariable
  • /iso/org/dod/internet/private/enterprise/6296/sleMgmt/sleRmon/sleAlarm/sleAlarmTable/sleAlarmEntry/sleAlarmVariable
  • /iso/org/dod/internet/private/enterprise/dasan/sleMgmt/sleRmon/sleAlarm/sleAlarmTable/sleAlarmEntry/sleAlarmVariable
  • /iso/org/dod/internet/private/enterprises/6296/sleMgmt/sleRmon/sleAlarm/sleAlarmTable/sleAlarmEntry/sleAlarmVariable
  • /iso/org/dod/internet/private/enterprises/dasan/sleMgmt/sleRmon/sleAlarm/sleAlarmTable/sleAlarmEntry/sleAlarmVariable
  • /iso/org/dod/internet/private/ldap-enterprise/6296/sleMgmt/sleRmon/sleAlarm/sleAlarmTable/sleAlarmEntry/sleAlarmVariable
  • /iso/org/dod/internet/private/ldap-enterprise/dasan/sleMgmt/sleRmon/sleAlarm/sleAlarmTable/sleAlarmEntry/sleAlarmVariable
  • /iso/org/dod/internet/private/vendor-objects/6296/sleMgmt/sleRmon/sleAlarm/sleAlarmTable/sleAlarmEntry/sleAlarmVariable
  • /iso/org/dod/internet/private/vendor-objects/dasan/sleMgmt/sleRmon/sleAlarm/sleAlarmTable/sleAlarmEntry/sleAlarmVariable
  • Additional combinations skipped.

SNMP properties

Value type
OBJECT IDENTIFIER
Maximum access defined by MIB
read-only
Status in MIB
current

Using this OID with SNMP

At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.

In SLE-RMON-MIB, the row index sleAlarmIndex is declared as INTEGER. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.6296.101.9.2.1.1.3.<sleAlarmIndex>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.

snmpwalk [connection options] DEVICE .1.3.6.1.4.1.6296.101.9.2.1.1.3

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

The displayed source records contain one distinct definition. Compare its source records.

sleAlarmVariable OBJECT-TYPE
			SYNTAX OBJECT IDENTIFIER
			MAX-ACCESS read-only
			STATUS current
			DESCRIPTION
				"The object identifier of the particular variable to
				be sampled.  Only variables that resolve to an ASN.1
				primitive type of INTEGER (INTEGER, Counter, Gauge,
				or TimeTicks) may be sampled.
				
				Because SNMP access control is articulated entirely
				in terms of the contents of MIB views, no access
				control mechanism exists that can restrict the value
				of this object to identify only those objects that
				exist in a particular MIB view.  Because there is
				thus no acceptable means of restricting the read
				access that could be obtained through the alarm
				mechanism, the probe must only grant write access to
				this object in those views that have read access to
				all objects on the probe.
				
				During a set operation, if the supplied variable
				name is not available in the selected MIB view, a
				badValue error must be returned.  If at any time the
				variable name of an establisled alarmEntry is no
				longer available in the selected MIB view, the probe
				must change the status of this alarmEntry to
				invalid(4).
				
				This object may not be modified if the associated
				alarmStatus object is equal to valid(1)."
			::= { sleAlarmEntry 3 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

The object identifier of the particular variable to be sampled. Only variables that resolve to an ASN.1 primitive type of INTEGER (INTEGER, Counter, Gauge, or TimeTicks) may be sampled. Because SNMP access control is articulated entirely in terms of the contents of MIB views, no access control mechanism exists that can restrict the value of this object to identify only those objects that exist in a particular MIB view. Because there is thus no acceptable means of restricting the read access that could be obtained through the alarm mechanism, the probe must only grant write access to this object in those views that have read access to all objects on the probe. During a set operation, if the supplied variable name is not available in the selected MIB view, a badValue error must be returned. If at any time the variable name of an establisled alarmEntry is no longer available in the selected MIB view, the probe must change the status of this alarmEntry to invalid(4). This object may not be modified if the associated alarmStatus object is equal to valid(1).

Sources for this description

DASAN Networks MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1DASAN Networks MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 1

sleAlarmVariable · currentDASAN Networks MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: sleAlarmVariable

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "sleAlarmVariable",
    "OBJECT-TYPE",
    "SYNTAX",
    "OBJECT",
    "IDENTIFIER",
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"The object identifier of the particular variable to be sampled. Only variables that resolve to an ASN.1 primitive type of INTEGER (INTEGER, Counter, Gauge, or TimeTicks) may be sampled. Because SNMP access control is articulated entirely in terms of the contents of MIB views, no access control mechanism exists that can restrict the value of this object to identify only those objects that exist in a particular MIB view. Because there is thus no acceptable means of restricting the read access that could be obtained through the alarm mechanism, the probe must only grant write access to this object in those views that have read access to all objects on the probe. During a set operation, if the supplied variable name is not available in the selected MIB view, a badValue error must be returned. If at any time the variable name of an establisled alarmEntry is no longer available in the selected MIB view, the probe must change the status of this alarmEntry to invalid(4). This object may not be modified if the associated alarmStatus object is equal to valid(1).\"",
    "::=",
    "{",
    "sleAlarmEntry",
    "3",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "OBJECT IDENTIFIER",
      null
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "The object identifier of the particular variable to be sampled. Only variables that resolve to an ASN.1 primitive type of INTEGER (INTEGER, Counter, Gauge, or TimeTicks) may be sampled. Because SNMP access control is articulated entirely in terms of the contents of MIB views, no access control mechanism exists that can restrict the value of this object to identify only those objects that exist in a particular MIB view. Because there is thus no acceptable means of restricting the read access that could be obtained through the alarm mechanism, the probe must only grant write access to this object in those views that have read access to all objects on the probe. During a set operation, if the supplied variable name is not available in the selected MIB view, a badValue error must be returned. If at any time the variable name of an establisled alarmEntry is no longer available in the selected MIB view, the probe must change the status of this alarmEntry to invalid(4). This object may not be modified if the associated alarmStatus object is equal to valid(1)."
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.6296)

Lee Wonhee

Siblings (11)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.6296.101.9.2.1.1.1 sleAlarmIndex00
1.3.6.1.4.1.6296.101.9.2.1.1.2 sleAlarmInterval00
1.3.6.1.4.1.6296.101.9.2.1.1.4 sleAlarmSampleType00
1.3.6.1.4.1.6296.101.9.2.1.1.5 sleAlarmValue00
1.3.6.1.4.1.6296.101.9.2.1.1.6 sleAlarmStartupAlarm00
1.3.6.1.4.1.6296.101.9.2.1.1.7 sleAlarmRisingThreshold00
1.3.6.1.4.1.6296.101.9.2.1.1.8 sleAlarmFallingThreshold00
1.3.6.1.4.1.6296.101.9.2.1.1.9 sleAlarmRisingEventIndex00
1.3.6.1.4.1.6296.101.9.2.1.1.10 sleAlarmFallingEventIndex00
1.3.6.1.4.1.6296.101.9.2.1.1.11 sleAlarmOwner00
1.3.6.1.4.1.6296.101.9.2.1.1.12 sleAlarmStatus00