Status in source: mandatory.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"serverStatus",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"unknown",
"(",
"1",
")",
",",
"stopped",
"(",
"2",
")",
",",
"running",
"(",
"3",
")",
",",
"running-missing",
"(",
"4",
")",
",",
"initializing",
"(",
"5",
")",
",",
"starting",
"(",
"6",
")",
",",
"disaster-recovery",
"(",
"7",
")",
",",
"postoffice-inconsistent",
"(",
"8",
")",
",",
"missing-jgroups",
"(",
"9",
")",
"}",
"ACCESS",
"read-only",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"The status of the StruxureWare Operations server: 1: The status of the application server is unknown. Check Webmin and if the problem persists, contact Technical Support. 2: Restart the StruxureWare DC Operation server. If the server was part of a cluster, see the StruxureWare DC Operation User Assistance about rejoining the cluster. If the problem persists, contact Technical Support. 3: No problem. 4: High availability is lost. The StruxureWare DC Operation Application server is running but one or more nodes are not available. If the StruxureWare DC Operation server is part of a cluster, ensure all nodes are running and there is a network connection between the nodes. If the problem persists, contact Technical Support. 5: Wait for the StruxureWare DC Operation Application server to initialize. If the problem persists, contact Technical Support. 6: Wait for the StruxureWare DC Operation Application server to finish starting. If the problem persists, contact Technical Support. 7: This node is running in Disaster Recovery mode. 8: The JBoss postoffice is currently inconsistent. This may be a temporary issue. If the problem persists for more than 10 minutes, contact Technical Support. 9: The JBoss is missing jgroups. This may be a temporary issue. If the problem persists for more than 10 minutes, contact Technical Support.\"",
"::=",
"{",
"struxureWareOperationsStatus",
"1",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"unknown",
1
],
[
"stopped",
2
],
[
"running",
3
],
[
"running-missing",
4
],
[
"initializing",
5
],
[
"starting",
6
],
[
"disaster-recovery",
7
],
[
"postoffice-inconsistent",
8
],
[
"missing-jgroups",
9
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"The status of the StruxureWare Operations server: 1: The status of the application server is unknown. Check Webmin and if the problem persists, contact Technical Support. 2: Restart the StruxureWare DC Operation server. If the server was part of a cluster, see the StruxureWare DC Operation User Assistance about rejoining the cluster. If the problem persists, contact Technical Support. 3: No problem. 4: High availability is lost. The StruxureWare DC Operation Application server is running but one or more nodes are not available. If the StruxureWare DC Operation server is part of a cluster, ensure all nodes are running and there is a network connection between the nodes. If the problem persists, contact Technical Support. 5: Wait for the StruxureWare DC Operation Application server to initialize. If the problem persists, contact Technical Support. 6: Wait for the StruxureWare DC Operation Application server to finish starting. If the problem persists, contact Technical Support. 7: This node is running in Disaster Recovery mode. 8: The JBoss postoffice is currently inconsistent. This may be a temporary issue. If the problem persists for more than 10 minutes, contact Technical Support. 9: The JBoss is missing jgroups. This may be a temporary issue. If the problem persists for more than 10 minutes, contact Technical Support."
],
null,
null,
null,
null
]
}